Battery packs do require routine maintenance and care to maximize their useful life and 

maintain warranty coverage. Read and follow the guidelines in this manual to safely use 

your lithium-ion battery packs and achieve battery life span.

Lithium-Ion Battery Maintenance Guidelines

According to leading cell manufacturers (LG, Samsung, Panasonic), the estimated life of a 

lithium-ion battery is 500 charge cycles. When stating approximate useful life of a battery 

in units of “charge cycles,” cell manufacturers define this as the point where the battery 

capacity (Ah) is reduced to 80% of original. This means battery is not “dead” after 500 

charge cycles, but runtime is significantly reduced, and replacement should be considered.

Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the battery 

does not need periodic full discharge cycles to prolong life.

Overview

Storage

When storing, remove battery packs from fan and store in a dry and cool location. Avoid 

extreme temperatures.

• Recommended Storage Temperature: 5

o

C to 20

o

C (41

o

F to 68

o

F)

• Maximum relative humidity during storage: 90% RH

NOTE: all batteries self-discharge during storage. Higher temperature (>20

o

C or 68

o

F) reduce 

the battery storage life.

Lithium-ion batteries should be stored in a charged state, ideally around 30% state of 

charge (SoC). See “Storage/Transport Mode” section of this manual for easy discharging 

steps to follow before storing battery packs.

Long-term (>6 months) storage of battery packs is not recommended. When a battery pack 

has been unused for 6 months, check the charge status and either charge or dispose of the 

battery as appropriate.

Recommendations 

• Battery packs will last significantly longer when run in pairs (two battery packs per fan) 

as there is 50% less discharge current per pack.

• As with any equipment, batteries will wear out faster with heavy use. Depth of 

Discharge (DoD) determines the cycle count of the battery. The smaller the discharge 

(low DoD), the less stress is enacted on the chemistry of the battery and the longer the 

battery will ultimately last. Ideally, operators should avoid full discharges and charge 

the battery after every use.

• Partial discharge of lithium-ion batteries is fine. There is no “memory effect” and the 

battery does not need periodic full discharge cycles to prolong life. Battery(s) will need 

to be replaced as they age.

Maintenance and Disposal

• DO NOT disassemble the ventilator for maintenance reasons.  

• Do not loosen screws on control box without contacting Euramco customer service. 

They are torqued to a setting to achieve water tightness. Clean ventilator periodically 

to remove accumulated dust or particles from ventilator guards. 

• Assembly screws are torqued to a specified value to achieve water tightness. 

Completely unravel power cord and place unit on a flat, stable surface. Clean ventilator 

periodically to remove accumulated dust or particles from ventilator guards, impeller 

blade and heat sink in rear of controller (ribbed). Use only biodegradable detergents. If 

power washing, avoid controller housing especially gaskets and control panel.

• Contact factory for replacement parts and installation instructions. To order spare 

parts call Euramco Group 

+1.619.670.9590 or [email protected]  

• Always dispose of your battery pack according to federal, state and local regulations.

  

• Even discharged batteries contain some energy. Before disposing of, use electrical tape 

to cover the terminals to prevent the battery pack from short circuit. 

• Properly dispose of battery packs when necessary. Contact your local hazardous 

materials e-waste collection department for details or proper disposal of rechargeable 

batteries.

Содержание EX150Li

Страница 1: ...trol 5 6 7 8 8 7 6 5 THE WRITTEN PERMISSION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Owner s Manual EX150Li HIGH PERFORMANCE BATTERY FAN ...

Страница 2: ...on 11 Connection of Battery Pack 11 12 Battery Operation Procedures 13 14 Run Time 14 Charging Procedure 15 The Fuel Gauge 16 Battery Status Indicator Lights 17 Battery Pack Protection 17 Storage Transport Modes 18 How to Activate Storage Transport Mode 18 AC Power Cord 19 Operating Limitations 19 Lithium Ion Battery Maintenance Guideline 20 Overview 20 Storage 20 Recommendations 20 Maintenance an...

Страница 3: ...ets worldwide through five locations globally Warning Labels and Safety Instructions This is the safety alert symbol When you see this symbol on your ventilator or in this manual be alert to the potential for personal injury or damage to your equipment Be sure you understand all safety messages and always follow recommended precautions and safe operating practices Important safety information is p...

Страница 4: ...SION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EL6500 2 WHL EL6500 2 WHL 2 EXTENDED HANDLE 1 1 FIRST ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE INCHES MM TOLERANCES APPLY TO PRIMARY INCH DIMENSION AND ARE AS INDICATED RADII 015 MAX UNLESS SPECIFIED ON DRAWING PAR...

Страница 5: ...n the ventilator Yellow Flashing STORAGE MODE Storage Transport Mode Plug Types The EX150Li is suitable for worldwide applications A voltage converter is not needed The unit includes a simple removable cord that allows the unit to operate up to 250 VAC Mainly used in Type Order North and Central America Japan B EL CUS 4762 France Belgium Germany Austria the Netherlands and most European countries ...

Страница 6: ...it says Align battery EX150Li and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard Operational Modes Input Voltage 90 250VAC 50 60Hz The ventilator is capable of operating seamlessly in countries that supply electricity at either 120V AC 60 Hz or 240V AC 50 Hz without manual adjustments by the user Operation out of these limits can dam...

Страница 7: ...runtime and airflow performance When using two battery packs each pack functions independently and is isolated from the other so that if one pack should fail open circuit short circuit or become discharged the other battery will provide power to operate the system When using dual batteries it s important that both batteries be of the same charge level and ideally of the same age and condition It s...

Страница 8: ...ll charge beforehand and also 100 efficiency Read Factors that affect Battery Life section 2 Batteries Speed Level Knob At maximum speed 45 minutes 11 At maximum speed and DC Max button activated 30 minutes Max button activated MAX Make sure the battery pack is connect correctly into the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During...

Страница 9: ...R PUSH FOR WAKE STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX If the battery is charging the green indicator lights will horizontally scroll from left to right turning solid green when the battery is fully charged If the ventilator is running on battery power the estimated remaining battery time is shown If all the lights flash red this ...

Страница 10: ...E STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX How to activate Storage Transport Mode AC Power Cord CORD STORAGE This battery fan was designed to replace corded AC fans optimizing cordless operations AC power cord is designed to be removable for the convenience of those users who choose to operate cordless AC power connector is a Push P...

Страница 11: ...attery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller the discharge low DoD the less stress is enacted on the chemistry of the battery and the longer the battery will ultimately last Ideally operators should avoid full discharges and charge ...

Страница 12: ...n warrantable failures Maintenance Schedule Battery packs should be inspected regularly for mechanical damage Dropping or any other heavy impact may compromise water ingress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk...

Страница 13: ...ces accessories RAMFAN s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow These PPV blowers have proven to be effective in controlling airborne contaminates replacing interior air removing heat and supplementing fixed ventilation systems By pressurizing properly and controlling the resultant flow path these ...

Страница 14: ...ue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA No 128 HeZhou Road JiaoChuan Street ZhenHai District Ningbo China 315207 Phone 86 57487979390 Fax 86 57487979391 theteam euramcosafety com SINGAPORE 1 Fullerton Road 02 01 One Fullert...

Отзывы: