MANUALE ISTRUZIONI / INSTRUCTIONS MANUAL
MTR605/025/DASM - R605/027/DASM - R605/170/DASM
Modello/Model R605DASM
K/ 5
is
tru_
ca
lib
_605
.fm
ASR003 - C
ALIBRAZIONE
\C
ALIBRATION
Figura 1
Calibration procedure
The calibration procedure needs to define the relationship between the stand and the
variation of the potentiometer signal to determine position values for FFD calculation.
The relation between the movement and the signal must be linear. Power up the board
and wait for collimator reset to be concluded.
At this point insert jumper between pin 2 and 4 of S3 to start the actual calibration.
Calibrazione della scheda esterna
External board calibration
Mettere il Jumper JP2 sulla scheda
ASR003 tra i pin 2 e 4 della fila sinistra
del connectore J3 iniziando il conteg-
gio dal pin inferiore - vedi
Figura 1.
Place jumper JP2 on board ASR003
between pins 2 and 4. The white line
and black arrow indicate where to po-
sition the jumper on board ASR003;
this requires the connection of pins 2
&4 of connector J3. See
Figure 1
collimatori\acs\asr003_3.jpg