background image

Rako RSRDMX Installation, Programming and Operating Instructions

General

Rako   RSRDMX   modules   are   15   Channel   DMX

controllers   for   use   with   DMX   drivers,   typically
controlling 3/4 colour light fittings.  

RSRDMX   modules   can   be   controlled   by   any   Rako

device that transmits wireless RAKOM messages.  

Before   commencing   installation   of   a   Rako   module
please   read   this   instruction   manual   carefully.     Rako

Controls Ltd accepts no responsibility for damage or
injury   caused   by   incorrect   installation   of   a   Rako

product.

Mounting

Rako modules should be mounted in areas that  are
adequately ventilated, dry and outside of any enclosed

metal   casings   that   may   interfere   with   the   wireless
signal.    

Modules   should   be   mounted   vertically,   with   the

terminals at the bottom, ensuring the ventilation slots
are not covered.  

Whilst Rako modules are designed to be completely

maintenance free the units should be mounted in an
accessible   location   should   there   be   a   fault   or   re-

addressing of the unit be necessary (see 'Set-up and
Addressing')

Connections

Remove the bottom two fixing screws and remove the
main lid.  

Power

Connect the 12V dc supply using the jack socket. 

Data

Connect the DMX data to the DMX device using either

the terminal connections or the RJ45 socket provided 
(see Fig. 2 overleaf).

Note

There is no formal standard for the connection of the 
Data + and Data – lines for DMX.  The most commonly

found connection type is supported by having the 
header connectors (see Fig. 2) in the NORMAL 

position.  If this does not work they can be placed in 
the INVERTED position, this reverses the Data + and 

Data – connections.

DMX Addressing

When giving the RSRDMX a Rako channel address the

next   14   channels   are   automatically   assigned,
sequentially from this point.   For example, a module

controlling an RGB fitting and addressed as channel 3
will control Red on channel 3, Green on channel 4 and

Blue on channel 5.

Initial Checks

When power is initially connected to the module the

unit should switch the load ON.  The load can then be
manually switched using the Set-up button under the

top cover (see Fig.2 overleaf).
The   factory   set   address   for   both   modules   and

transmitters is House 1 Room 4 (See Fig 1 for further
information).  A Rako wireless wallpanel set as address

House 1 Room 4 will control the module.
Should the module not respond as above then further

investigation   should   be   made   before   proceeding
further.

Fig.1

Set-Up and Addressing

RSRDMX modules can be programmed manually or by
using RASOFT programming software.   For software

programming   refer   to   the   appropriate   programming
guide   supplied   as   a   PDF   with   the   programming

interface (RA or RTC-Bridge etc.) or download from
our website:

www.rakocontrols.com.

To access the Set-up button necessary for both 
software and manual addressing remove the top screw

and top cover (see Fig.2 overleaf)

Manual Addressing from Wallplate or Handheld

Before any lighting scenes can be programmed (see

the   wall-panel   or   hand-held   manual)   the   RSRDMX
module needs to be addressed.

To   avoid   interference   between   neighbouring

installations choose a House address other than the
factory   default   of   House   1   and   set   this   on   the

transmitters using the House address switches.  Keep
the House address the same throughout the project

(for master functions).  

Choose a Room address for each separate room or area
to   be   controlled   independently   and  set   this   on   the

appropriate   transmitters   using   the   Room   address
switches.  Note: Any control panels set with the same

address will act as two or multi-way controls for the
same Room.

The module now needs to be sent its new House and

Room   address   from   the   appropriate   keypad.     For
rooms with multiple modules each module needs to be

also assigned a separate Channel number from 1-15
within each Room.

The   House   and   Room   addresses   are   set   using   the

switches on the back of a Rako transmitter (see Fig 1)
and the Channel addresses are selected by putting a

transmitter   in   programming   mode   and   ‘stepping’
through the channel numbers (see Step 3 overleaf).

This number is then 'sent' (along with the House and
Room address) to a receiver (Step 5).

Notes on address switches

The address numbers are set using the switches on the
back of a Rako transmitter.  Binary coding is used and

a diagrammatic explanation is given in Fig 1.  It is not
however necessary to understand binary just set the

House switches to a different setting than the factory
default   and   use   a   different   combination   of   Room

switch settings for each room or area to be controlled
separately.  

Notes on Addressing

A module cannot be set to an address of House 0 (All
switches set to off)

A module will respond to, but not receive an address
of   Room   0   (All   switches   set   to   off).   This   Room   0

address is used for ‘Master House’ control 
A module cannot be set to channel 0.

To program a lighting scene see Wall panel or Hand
held manual.

Power-Up Mode

With   the   factory   address   setting   of   House   1   an

RSRDMX will turn ON when power is applied.  When
the   House   address   is   changed   the   Power-Up  mode

becomes   'OFF'   which   is   generally   preferred,   for
instance if there is a power cut during a holiday.

Manual Operation

The set-up button can be used as a manual On/Off
switch.

Multiple Control Panels

If the module is to be controlled by two wall or hand-
held transmitters it is only necessary to address the

module to one of these transmitters.   Set the other
transmitters to the same House and Room address and

they  will  transmit   exactly  the   same   message   as  the
first   transmitter   and   the   module   will   respond

accordingly.

LED functions

The internal LED will flicker when the module receives

ANY Rako wireless message and is a useful diagnostic
indicator.

If an RSRDMX module has already been addressed to
a   wall-panel   the   internal   LED   will   start   to   pulse   as

soon as that transmitter (or any other transmitter with
the same address) is put into programming mode.  The

module can still be re-addressed in the normal way, for
example when changing its Channel address within the

same Room.

Colour Cycling

As a default setting the RSRDMX module will not

dim from Fade Up/Down commands from a Rako
transmitter but instead will start a colour cycle 

through
the colours programmed for Scenes 1–4 when it

receives a Fade Up command. A Fade Down command
will stop the cycling

Care and Maintenance

A   Rako   module   contains   no   user   serviceable   parts.
Should for any reason you need to contact us please

contact us via our website  

www.rakocontrols.com

  or

by phoning our customer help line on 01634 226666.