Terminating the RAK-LINK  

The final step in the installation process is to terminate the RAK-LINK.  The termination that 
is required depends on the nature of the installation and the position of the RAK-LINK within 
the system.  
 

Termination Jumper settings: 

 

 

 

 

No Term - Both Jumpers removed 

Used when the RAK-LINK is not at the end of line. This is usually identifiable by two cables 
being punched down to the RAK-LINK.  
 

Term - Jumper fitted across 1+2 & 4+5 

Used when the RAK-LINK is end of line in a daisy chain configuration (such as the 
RAK-LINK shown in “Typical Wired Installation layout” on page one). 
 

Star Term - Jumper fitted across 2+3 & 5+6 

Used when the RAK-LINK is end of line in a STAR wire configuration.  

Programming the RAK-LINK 

The RAK-LINK is programmed using the Rasoft pro programming software.  A 
WA/WTC-Bridge is required for any programming of a wired system.  

 

For more information on how to programme a RAK-LINK please refer to “Wired System 
Setup Guide”

 

 

 