Raisecom
RC3000-15 (P100R001) Hardware Description
12 Telecontrol service cards
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
181
Input
Output
NMS
display
Status
Description
Status
Description
OFF
The input switch is off, and no
alarms are input.
Contact
Normal
The COM pin and CLOSE
pin of the Phoenix terminal
are connected.
Contact
Normal
ON
The input switch is on, and
some alarm is input.
Contact
Operated
The COM pin and OPEN pin
of the Phoenix terminal are
connected.
Contact
Operated
12.1.5 LEDs
Table 12-7 lists LEDs on the DRYC card.
Table 12-7
LEDs on the DRYC card
LED
Color
Description
PWR
Green
Power LED
Green: the power supply is normal.
Off: the power supply is abnormal.
SYS
Green
System status LED
Green: the system is working improperly.
Off: the system is working improperly.
Blinking green: the system is working properly.
12.1.6 Specifications
Table 12-8 lists parameters of the DRYC card.
Table 12-8
Parameters of the DRYC card
Parameter
Description
Dimensions
25 mm (Width) × 232 mm (Depth) × 240 mm (Height)
Weight
0.45 kg
Power consumption
< 2.4 W
12.1.7 Networking applications
Point-to-point application
As shown in Figure 12-2, two RC3000-15 devices are inserted with a DRYC card respectively.