Raisecom
ISCOM6820-GP (A) Installation Guide
8 Installation reference
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
44
The meaning of the cable label:
A01-03-02-01: indicates the local device connected by the network cable, namely,
Ethernet port 1, Slot 2, Frame 3, in the cabinet in Row A Column 1.
B01-03-02: indicates the device connected by the other end of the network cable, namely,
Ethernet port 2, Frame 3, in the cabinet in Row B Column 1 in the equipment room. No
slot No.
8.2.5 Project label of optical fiber
Project label of the optical fiber contains the fiber labels between devices and the fiber labels
from device to Optical Distribution Frame (ODF), which applies to fibers of card optical
interfaces in the cabinet, chassis or cassette devices.
Fiber label can be divided into two types according to the application scenarios:
Connection between devices: the label is pasted on the fiber which connects two devices.
Connection between device and ODF: the label is pasted on the fiber which connects the
device and ODF.
Fiber labels between devices
The meaning of fiber labels between devices is shown in Table 8-3.
Table 8-3
Meaning of fiber labels between devices
Lable content
Meaning
Example
MN-X-Y-Z-R/T MN: Cabinet No.
M: devices from front to end in the equipment room are called a
row of devices, numbered A–Z.
N: devices from left to right in the equipment room are called a
column of devices, numbered 01–99.
For example: B03 indicates the device in Row B, Column 01.
X: Chassis No.
Ordered from bottom top with two numbers, such as 01
Y-Card/Slot No.
Ordered from left right, top bottom, numbered from 1
For example: 1 indicates Card 1.
Z: Optical interface No. Ordered from top bottom, left right, numbered from 0
For example: 0 indicates the first optical interface.
R: Optical Rx interface
T: Optical Tx interface
N/A
MN-X-Y-Z-R/T MN: Cabinet No.
M: devices from front to end in the equipment room are called a
row of devices, numbered A–Z.
N: devices from left to right in the equipment room are called a
column of devices, numbered 01–99.
For example: A01 indicates the device in Row A, Column 01.
X: Chassis No.
Ordered from bottom top with two numbers, such as 01