background image

www.raisecom.com                                                                                                                                     

 User Manual

 

 

2           

be present inside certain products even when the power switch (if installed) is in the OFF position or 
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, 
energy hazards may still exist. 
Before working on equipment connected to power lines or telecommunication lines, remove jewelry 
or any other metallic object that may come into contact with energized parts. 
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding 
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth 
lug is provided on the product, it should be connected to the protective earth at all times, by a wire 
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed 
racks and cabinets. 
Always make the ground connection first and disconnect it last. Do not connect telecommunication 
cables to ungrounded equipment. Make sure that all other cables are disconnected before 
disconnecting the ground. 

Connection of AC Mains 

Make sure that the electrical installation complies with local codes. 
Always connect the AC plug to a wall socket with a protective ground. 
Always connect the power cord first to the equipment and then to the wall socket. If a power switch 
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily 
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency 
switch is installed in the building installation. 

Connection of DC Mains 

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to 
the ground. Any single pole can be externally grounded. 
Due to the high current capability of DC mains systems, care should be taken when connecting the 
DC supply to avoid short-circuits and fire hazards. 
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to 
qualified service and maintenance personnel. 
Make sure that the DC supply is electrically isolated from any AC source and that the installation 
complies with the local codes. 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF position. 
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, 
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated in 
the building installation. 

Preventing Electrostatic Discharge Damage 

Modules which can be plugged into chassis are sensitive to damage from static electricity. 
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam 
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper 
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. 
To minimize the potential for ESD damage, observe the following guidelines: 
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good 
skin contact. 
• When removing or installing a component, make sure the equipment end of your antistatic strap 
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal 
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only 
protects the component from ESD voltages on the body; ESD voltages on your clothing can still 
cause component damage. 
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a 
static shielding bag. If you are returning the item to the factory, immediately place it in a static 
shielding bag. 
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector 
pins. 

Содержание ISCOM2828F

Страница 1: ...www raisecom com ISCOM2828F Hardware Installation User Manual ...

Страница 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2006 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Страница 3: ...x 86 10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2828F device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus ...

Страница 4: ...nce 5 3 1 Device front panel description 5 3 2 Device rear panel description 7 Chapter 4 Installation and Application 8 4 1 Device model 8 4 2 Device installation 9 4 2 1 Environment requirement 9 4 2 2 Install the device on to a rack 9 4 2 3 Grounding 9 4 3 The connection of the switch 9 4 3 1 Connect to console 9 4 3 2 The connection of the switching interfaces 11 4 3 3 Connect to the power supp...

Страница 5: ...nd other relevant reference documents and explains relevant term definitions Chapter 2 Specifications and Dimension This chapter is an instruction of the device specifications device dimension and device operating environment Chapter 3 Device Appearance This chapter describes the panel of the device and the definition of the indicators on the device panel Chapter 4 Installation and Application Thi...

Страница 6: ...at the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous...

Страница 7: ...nstalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that servi...

Страница 8: ...running at 100Mbps 1000BASE X A term in IEEE 802 3 for Gigabit Ethernet over fiber based on 8B 10B coding and running at 1000Mbps Auto Negotiation The auto negotiation procedure is the port at one site adapts its bit rate and duplex mode to the highest level it and the opposite site device both support according to the bit rate and duplex mode adopted by the remote site device that is the connecte...

Страница 9: ...00BASE X Ethernet interface in the form of SFP and 2 1000BASE T Ethernet interface in the form of RJ 45 The power consumption of the system is less than 40W 2 2 Device dimension The dimension of ISCOM2828F switch s main structure is 442mm x 43 8mm x 360mm Width x Height x Depth The device weighs 5 8kg and can be either fixed into a 19 inch cabinet or placed on a table 2 3 Device operating environm...

Страница 10: ...ering The system is operating in order SYS Green Other Status Software fault or the system is initializing after electrifying When the system is just electrified it will take about 1 minute to initialize During the initialization the indicator SYS will not flicker ON The power supply module 1 is electrified PWR1 Green OFF The power supply module 1 is not electrified or fault occurs on the power su...

Страница 11: ...NK ACT and 1000M Indicator Color Status Description ON The port is in Link Up status Flickering The port is transmitting or receiving data LNK ACT Green OFF The port is in Link Down status ON The corresponding interfaces is working at the rate of 1000Mbps in Link Up status 1000M Green OFF The corresponding port is abnormal when it is in Link Up status The interface 1 24 are 100BASE FX Ethernet int...

Страница 12: ...re the socket and switch for the 220V AC power supply 1 locates The place where the socket and switch for the 220V AC power supply 2 locates The place where the grounding terminal locates 2 The socket for 48V DC power supply When ISCOM2852 adopting 48V DC power supply the position of the power supply socket on the device s rear panel is shown in the figure below 1 2 3 In the figure shown above The...

Страница 13: ...ance S3 SFP optical module USFP 03 SS13 100M single strand transmitting distance S1 transmitting wavelength 1310nm SFP optical module USFP 03 SS15 100M single strand transmitting distance S1 transmitting wavelength 1550nm SFP optical module USFP 03 SS23 100M single strand transmitting distance S2 transmitting wavelength 1310nm SFP optical module USFP 03 SS25 100M single strand transmitting distanc...

Страница 14: ...le on to the rack 4 2 3 Grounding To ensure the safety of the device and the operator please make sure that the grounding terminal is well connected to the earth 4 3 The connection of the switch 4 3 1 Connect to console ISCOM2828F switch provides a RS 232 interface in the form of RJ 45 as the CONSOLE interface After connecting the CONSOLE interface of ISCOM2828F switch to the serial port on the PC...

Страница 15: ...tion Type Pin Number Function Type 1 CD 6 DSR 2 RxD IN 7 RTS 3 TxD OUT 8 CTS 4 DTR 9 RI 5 GND 3 CONSOLE interface connecting pattern and parameter setup The connecting of ISCOM2828F CONSOLE interface and PC serial port is shown in the figure below RxD TxD GND RxD TxD GND PC Serial Pot CONSOLE 3 2 5 6 3 4 5 The values of the connecting parameters of the terminal simulation program on the PC are as ...

Страница 16: ...o connect the device to the 1000BASE X interface of the opposite device The TX of the SFP module must be connected to the RX of the opposite device while the RX of the SFP module must be connected to the TX of the opposite device The connecting of interface 27 and 28 ISCOM2828F provides 2 10 100 1000M Ethernet electrical interfaces Both of the interfaces are in support of auto MDI MDIX function an...

Страница 17: ... the steps above connect the switch to 220V AC power supply or 48 DC power supply using the provided power supply cable and then the switch is electrified After the electrifying the indicator PWR will turn ON to indicate that the power supply of the system is working The switch will begin its self check and initialization in succession All the indicators on the front panel of the switch will turn ...

Страница 18: ...www raisecom com User Manual 13 operate over the switch will appear on the PC For details please refer to the corresponding software configuration manual ...

Страница 19: ...ow humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some space from other powered devices when installing the switch The cable arrangement of the switch should have all cables be placed across the live wire Long distance close parallel of the cables and the ...