Raisecom
ISCOM RAX711 (B)Product Description
Raisecom Technology Co., Ltd.
33
5.6.3 Operation environment
Atmosphere environment
Table 5-9 lists atmosphere requirements for the ISCOM RAX711 during operation.
The temperate and humidity referred to are measured 1.5 m above or 0.4 m in front
of the ISCOM RAX711.
Table 5-9
Atmosphere requirements during operation
Item
Value
Air pressure (kPa)
86–106
Altitude height (m)
≤ 4000
Temperature (°C)
-40 to +70
We do not recommend making the
ISCOM RAX711 work 70°C
permanently, because this shortens
its life.
Temperature (°F)
-40 to +158
We do not recommend making the
ISCOM RAX711 work 70°C
permanently, because this shortens
its life.
Relative humidity
5%–95% RH (non-condensing)
Temperature change rate (°C/min)
≤ 0.5
Solar radiation (W/s²
)
≤ 700
Heat radiation (W/s²
)
≤ 600
Wind speed (m/s)
≤ 5
5.6.4 Biotic environment
Keep the ISCOM RAX711 away from:
Reproduction of fungus and mould
Existence of rodent animals such as rats