The wiring of cables should meet design requirements.
Check
5
No damage, breakage, or middle joints for signal cables
Check
6
Labels on the two ends of the signal cable are correct, distinct, and
neat.
Check
7
The curvature radius of an optical fiber should be 20 times greater than
the diameter. In general, it should be greater than 40 mm.
Check
8
The wiring of the power cable and ground cable should comply with
engineering design documents to facilitate capacity expansion.
Check
9
Power cables and signal cables are laid separately.
Check
10
No stains or scratches on the surface of the device
Check
11
The capacity of the fuse is large enough to support the device to work
properly under the maximum power consumption.
Use a
tester.
12
When making the wiring nose of the power cable, ground cable, or the
alarm cable, weld or clamp it tightly.
Check
13
The power cable and the ground cable are properly connected. The
spring washer is over the flat washer.
Check
14
Space for heat dissipation is reserved around the device. No heavy
object is laid on the device.
Check