Raisecom
Gazelle S1020i-GL (A) User Manual
3 Technical specifications
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
43
Parameter
Description
(altitude: 0–1800 m)
Working humidity
5%–95% RH (non-condensing)
Protection class
IP40
Power
supply
DC
power
supply
Rated
voltage
Gazelle S1020i-2GF-4GE-P WH-GL-DC48: 48V DC
Gazelle S1020i-4GF-8GE-P WH-GL-DC48: 48V DC
Gazelle S1020i-2GF-4GE-GL-DC W48: 24/48V DC
Gazelle S1020i-4GF-8GE-GL- DC W48: 24/48V DC
Voltage
range
Gazelle S1020i-2GF-4GE-PWH-GL-DC48: 45–57
VDC
Gazelle S1020i-4GF-8GE-PWH-GL-DC48: 45–57
VDC
Gazelle S1020i-2GF-4GE-GL: 20–72 VDC
Gazelle S1020i-4GF-8GE-GL: 20–72 VDC
AC
power
supply
Rated
voltage
110/220 VAC
110/220 VDC
Voltage
range
85–264 VAC
88–300 VDC
Frequency
50/60 Hz
3.2 Compliance standards
IEC 62351 Power systems management and associated information exchange - Data and
communications security
IEC 61588 Precision clock synchronization protocol for networked measurement and
control systems
IEEE 802.3 Information Technology
IEEE1613
3.2.1 Environmental standards
The Gazelle S1020i-GL is applicable to the industrial environment with environmental
requirements shown in Table 3-2.
Table 3-2
Environmental requirements
Parameter
Description
Air pressure
86–106 kPa
Operating temperature (altitude: 0–1800 m)
-40 to 75°C
Storage temperature
-40 to 85°C
Operating humidity
5%–95% RH (non-condensing)