ENGLISH RAIS - manual for Q-20
9
Installation
When installing the wood burning stove, there are some rules which MUST be followed:
The stove must be set up and installed in accordance with all current national and local
rules and regulations. Local authorities and a chimney specialist should be contacted prior
to set up.
It is prohibited to carry out unauthorised alterations to the stove.
There must be plenty of fresh air in the room where the stove is being installed, in order
to ensure proper combustion. Note that any mechanical exhaust ventilation - e.g. an
extraction hood - may reduce the air supply. Any air grates must be placed in such a man-
ner, that the air supply is not blocked.
The floor structure must be able to carry the weight of the wood burning stove, as well as
the weight of a chimney, if necessary.
When you choose where to set up your RAIS wood burning stove, you should consider
the heat distribution to the other rooms. This will enable you to get the best use out of
your stove.
The stove should be set up at a safe distance from inflammable materials.
See the manufacturer’s plate on the wood burning stove.
Installation distance in case of combustible wall
To find out whether the wall next to where the stove is going to be installed is flammable,
you should contact your building contractor or the local building authorities.
The hearth should be able to accommodate the weight of the stove. The chimney must
be independently supported by wall brackets or a ceiling support plate. The weight of the
stove is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construc-
tion that is in accordance with the provisions of the current UK Building Regulations Ap-
proved Document J.
If the stove is to be installed on a wooden floor, it must be covered with a noncombustible
material at least 12mm thick, in accordance with UK Building Regulations Approved Docu-
ment J, to a distance of 300 mm in front of the stove and 150 mm to each side measuring
from the door of the combustion chamber.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of
combustible material given in UK Building Regulations Approved Document J and also in
these stove instructions.
Содержание Q20
Страница 2: ...We cannot be held responsible for any misprints...
Страница 23: ...ENGLISH RAIS manual for Q 20 23...
Страница 25: ...ENGLISH RAIS manual for Q 20 25 1 2 5 7 8 9 3 4 10 11 12 14 13 6...
Страница 26: ...26 Fran ais Manuel d utilisateur pour les mod les Q 20 Sous r serve d erreurs typographiques...
Страница 45: ...45 Fran ais Manuel d utilisateur pour les mod les Q 20 1 2 5 7 8 9 3 4 10 11 12 14 13 6...
Страница 46: ...46 Flemish Gebruikershandleiding voor Q 20 Onder voorbehoud van drukfouten...
Страница 65: ...65 Flemish Gebruikershandleiding voor Q 20 1 2 5 7 8 9 3 4 10 11 12 14 13 6...
Страница 66: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk N O R D I S K MILJ M RKN I N G 5 7 8 0 0 5...