VERTICAL ROOF TERMINAL, TYPE C31
NB:
Examples of flue solutions are shown at the back of the manual under the section ‘Examples of flue
solutions’ .
Vertical roof terminal, type C31
Dimensions of flue pipe:
The fireplace is supplied with an outlet spigot Ø100/Ø150 mm or Ø130/Ø200 mm, depending on the mod-
el . This flue dimension can be used for the entire flue . Alternatively, a Ø130/Ø200 adapter can be fitted, so
that this flue dimension can be used for the rest of the flue .
Flue terminal:
Ø130/Ø200 Item no . USDVC 130
Ø100/Ø150 Item no . USDVC 100
Minimum vertical length of flue pipe 0 .5 m .
Restrictor plate in flue, Ø100/150 and Ø130/200
Fit the flue gas restrictor for Ø100/Ø150 together with the interior flue gas spigot!
Vertical height < 1 m: No restrictor
Vertical height 1–2 m: Ø76 mm restrictor
Vertical height 2-8 m: Ø62 mm restrictor
Vertical height > 8 m: No restrictor
62
76
Pipework
When you start installing the pipework for the gas fireplace, it is im-
portant that the flue pipe faces the correct way . The end must only
have a single “ring” facing down in the gas fireplace . See image .
GB - 33
GB
Содержание Nexo 100
Страница 15: ...DIMENSIONAL DRAWINGS VIVA L GAS Viva L 140 Gas GB 15 GB...
Страница 87: ...DECLARATION OF PERFORMANCE GB 87 GB...
Страница 88: ...DECLARATION OF PERFORMANCE 88 GB GB...
Страница 89: ...DECLARATION OF PERFORMANCE GB 89 GB...
Страница 90: ...DECLARATION OF CONFORMITY 90 GB GB...
Страница 91: ...DECLARATION OF CONFORMITY GB 91 GB...
Страница 92: ...DECLARATION OF CONFORMITY 92 GB GB...
Страница 93: ...TROUBLESHOOTING TROUBLESHOOTING See the troubleshooting section in the separate user guide GB 93 GB...
Страница 94: ...94 GB GB...