If it is found that there is excessive draught in the chimney then either an
adjustable flue damper or alternatively a draught stabiliser should be fitted. The
adjustable flue damper should not close off the flue entirely, but should in its
closed position leave a minimum continuous opening free area of at least 20 % of
the total cross sectional area of the flue or fluepipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for
sweeping the chimney and connecting fluepipe.
You should also familiarise yourself with the draught conditions for chimneys with
2 flues.
For strong draughts, the chimney or flue should be fitted with a draught
stabiliser. In which case, it is important to ensure that there is a free flowthrough
area of minimum 20 cm
2
when the regulating gate is shut. Otherwise, the fuel en
ergy may not be used optimally.
If, at any time, you are unsure about the condition of the chimney, you should
contact a chimney sweep.
Remember that access to the soot door should be kept clear.