![RAIS 600-1 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/rais/600-1/600-1_installation-manual_3483674016.webp)
INSTALLATION DISTANCE: 600-2
A-A
B-B
A
A
B
B
RAIS 600 Opstillingsafstand 2G
50
0
1000
950
950
50
50
175
350
300
A-A
B-B
A
A
B
B
RAIS 600 Opstillingsafstand 2G
50
0
1000
950
950
50
50
175
350
300
A-A
B-B
A
A
B
B
RAIS 600 Opstillingsafstand 2G
50
0
1000
950
950
50
50
175
350
300
A non-flammable panel must be fitted directly above
the convection opening so that “standing” hot air does
not develop above the convection opening. This is
done to protect the ceiling and to transport the heat
out of the fireplace insert.
DISTANCE FROM
DISTANCE IN MM
Furniture to door
950
Furniture to side glass
950
Panels to fireplace insert
50
Ceiling to door top edge
1000
Ceiling from convection
opening
500
Floor to door bottom edge
300
Flammable at side of door
350
Firewall extension
175
EN - 15
EN
INSTALLATION DISTANCE
The insulated part of the chimney must extend all the
way down to the flue spigot.