Product Certification Information
The QRS H series is tested and certified by the WQA to NSF/ANSI
Standard 42 and 53 for the specific performance claims as verified and
substantiated by test data.
Water treatment devices sold to retail consumers in California, accom-
panied by certain health claims, must be certified by the State of
California Department of Public Health. This product is not certified in
the State of California for the purpose of making health claims.
Installation Instructions
1. Safety Precautions
• To prevent accidents and/or injuries, do not hoist the equipment
over your shoulder; use a hand truck.
• Do not lay the system on its side.
• Wear safety glasses and work gloves during installation and service.
2. Test the Raw Water
• If water contains iron, manganese or hydrogen sulfide, a seperate
iron removal system is suggested to be installed prior to the filter,
consulting with your local dealer.
3. Check the Water Pressure
• The minimum water pressure is 20 psi and the maximum water
pressure is 120 psi. Use a pressure gauge to confirm that the water
pressure does not exceed 120 psi. If the water pressure does exceed
this limit, install a pressure regulator on the inlet pipe to the system.
Set the pressure regulator at a maximum of 60 psi, which is the
optimum operating pressure.
4. Locate a Site for the System
• There is only one requirement needed for a site: the main water
source. Locate the system as close to the water meter or pressure
tank as possible.
• Place the system in the desired location. The location must have a
level, smooth, and clean surface.
• If the system is located outdoors, protect the unit from direct
sunlight; direct sunlight can damage the fiberglass and other system
components. If necessary, build a box or shed.
5. Turn Off the Water and Drain the Plumbing
• Turn off the water at the meter or pressure tank.
• Drain all the pipes. Do not sweat pipes with water in them; steam
will damage the plastic parts in the valve.
• To drain the plumbing system, open all faucets in the house and
flush the toilets. The water will drain out of the lowest faucet or
outlet and air will enter the plumbing system.
6. Provide Untreated Water for Irrigation or Outdoor Watering
• If available, run an untreated water line to outside faucet or provide
a hose connection on untreated line prior to the system.
4
!
Important Note: The system can only be
installed outdoors in climates that do
not reach freezing levels.
!
For Massachusetts Residents Only:
The Commonwealth of Massachusetts
Plumbing Code 248 CMR shall be
adhered to. A licensed plumber shall be
used for this installation