Operational Specifications
Plumbing
3/4 inch to 1 1/4 inch
Drain Line
1/2 inch
Water Pressure
20 psi_120 psi (1.38 bar _ 6.89 bar)
Operating Temperatures
40° F_100° F (4.4° C _ 37.8° C)
Electrical Requirements
A properly grounded alternating current supply (110 VAC 60 Hz or 230
VAC 50 Hz) is required for the operation of this system. Please check the
transformer for the correct voltage requirements.
Bypass Valve
The bypass valve enables you to bypass the system in situations of: emer-
gency leaks in the equipment, service calls and/or outdoor water use.
Existing Plumbing Conditions
Plumbing should be free from lime and/or iron buildup. Piping that
contains large amounts of lime and/or iron should be replaced. If piping
is clogged with iron, a separate iron filter should be installed in-line,
before the water conditioner.
Additional Specifications
• Do not install this system where water is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
• This system must be installed in accordance with all applicable state
and local laws and regulations.
• The Commonwealth of Massachusetts Plumbing Code 248 CMR shall
be adhered to. A liscence plumber shall be used for this installation.
• This system must be installed in an area not affected by extreme heat,
cold or the elements. The selected installation area must be adequate
for easy service and accessibility.
• This system is designed to treat cold water only. The installation must
be on a cold water supply.
Data Chart for ION-X 2000 V Resin
*
Cation Exchange Media
**
The conditioners are efficiency rated
according to
NSF/ANSI 44. The effi-
ciency of the conditioner is valid
only at the stated salt dosage.
Higher or lower pressure will affect the effi-
ciency of
the system.
***
Only the following models are
certified in the State of California: EC4 75 CV,
EC4 100 CV, EC4 150 CV, EC4-CAB 60 CV and
EC4-CAB 100 CV. All other models are not
certified in the State of California for the
purpose of making health claims.
!
Important Note: This system
requires the use of the supplied
transformer (24 VAC).
Model
Tank Size
(inches)
Resin*
(cu. ft.)
Service
Flow
(gpm)
Drain
Flow
(gpm)
psi Drop
High
Salting
Medium
Salting
Low
Salting
Efficiency**
EC4 50 V
8 x 44
0.5
10.0
1.5
14.0
18,700 @
7.5 lbs.
16,000 @
5.0 lbs.
8,900 @
2.0 lbs.
4,470 @
2.0 lbs.
EC4 50 CV
8 x 44
0.5
10.0
1.5
14.0
18,700 @
7.5 lbs.
16,000 @
5.0 lbs.
8,900 @
2.0 lbs.
4,470 @
2.0 lbs.
EC4 60SS V
10 x 18
0.6
9.5
2.0
10.0
22,000 @
9.0 lbs.
18,700 @
6.0 lbs.
10,500 @
2.4 lbs.
4,370 @
2.4 lbs.
EC4 60SS CV
10 x 18
0.6
9.5
2.0
9.0
22,000 @
9.0 lbs.
18,700 @
6.0 lbs.
10,500 @
2.4 lbs.
4,370 @
2.4 lbs.
EC4 60S V
10 x 35
0.6
9.5
2.0
10.0
22,500 @
9.0 lbs.
19,200 @
6.0 lbs.
10,700 @
2.4 lbs.
4,470@
2.4 lbs.
EC4 60S CV
10 x 35
0.6
9.5
2.0
10.0
22,500 @
9.0 lbs.
19,200 @
6.0 lbs.
10,700 @
2.4 lbs.
4,470@
2.4 lbs.
!
Important Note: The manually
operated bypass valve enables
the conditioner to be isolated
from the water service line for
maintenance and service. It also
maintains the continuity of the
water supply when the condi-
tioner is disconnected.