background image

3

Congratulations

on  your  purchase  of  a  RainSoft  water  treatment

system.

This Owner’s Manual is designed to assist with the operation, mainte-
nance, and installation of your water treatment system. It is our sincere
hope  that  this  manual  is  clear,  concise,  and  helpful  to  you  as  a  new
owner.

Questions? 

If you have any questions regarding the installation, oper-

ation,  or  servicing  of  this  system,  please  contact  your  local  RainSoft
Dealer.  Your  local  RainSoft  Dealer  is  familiar  with  your  particular
water conditions, and is able to address your concerns promptly and
efficiently.

Information on Water Treatment
Systems

There are many misconceptions that have been developed about water
treatment  systems.  The  most  common  topic  of  confusion  is  the
amount  of  sodium  (Na),  not  table  salt  (NaCl),  that  is  added  to  the
water from a water conditioner. In reality, ion exchange does replace
the  hardness  ions  in  your  water  with  sodium  ions,  but  the  common
misconception is the amount used.

For  every  1  grain  of  hardness,  the  exchange  process  will  deliver
approximately 8 milligrams of sodium per 1 liter of water. The amount
of sodium present in a standard 8 ounce glass of treated water, that was
10 grains hard prior to treatment, would be around 19 milligrams of
sodium.  This  is  an  insignificant  amount  of  sodium  considering  a
typical slice of white bread has about 140 milligrams.

Another  common  misconception  that  needs  mentioning  is  the
amount of salt used by the conditioner to regenerate the system. In the
past, water conditioners used more salt to regenerate, but that was due
to  old  technology  and  standards.  Water  conditioners  do  use  salt  for
regeneration, but the amount of salt varies by water consumption and
hardness levels. Fortunately, today’s technology allows us to dispense
just the right amount of salt for maximum efficiency, based on your
individual water consumption needs.

Application Limitations

• On  hardness  levels  of  60  grains  and  higher,  the  system  may  not

achieve a hardness of less than 1 grain; due to high Total Dissolved
Solids,  some  bleed  through  is  possible.  Bleed  through  can  also  be
caused by sodium levels higher than 1000 parts per million. In either
case, your system can be programmed to minimize these effects. See
your RainSoft Dealer for details.

• Chlorine or Chloramine levels on municipality treated water should

not exceed 4 parts per million.

*

When Chlorine or Chloramine levels

are 4 parts per million

*

or greater, it can have adverse effects on your

system. In applications where high levels are a concern, pre-filtration
is necessary to reduce the Chlorine or Chloramine to an acceptable
level. See your RainSoft Dealer for details.

• When this system is installed on water with Ferrous iron, also known

as clear water iron, the maximum range of removal is based on local
water  conditions.  The  range  is  generally  2  to  10  parts  per  million.
Your  equipment  may  require  special  programming,  along  with  an
additive  to  the  brine  tank,  to  maximize  the  equipment’s  ability  to
remove iron. See your RainSoft Dealer for details.

!

Important  Note: Oxidizing  agents,
such  as  Chlorine  or  Chloramine  in
excess  of 4  ppm, and/or  Ferrous
iron will foul the resin bed. Fouled
resin  is  not  eligible  for  warranty
replacement.

!

Important  Note: This  system  may
be  in-stalled  on  well  water  or
municipality 

treated 

water

supplies.

!

Important  Note: Most  municipality
treated  water  supplies  contain
Chlorine  as  a  disinfectant. Many
municipalities also inject ammonia
into  the  water  supply, creating
Chloramine.

Maximum  disinfectant  level  of
Chlorine  or          Chloramine  recom-
mended from the EPA.

*

Helpful  Tip:

Another  common

misconception  of water  treatment
systems is the idea that soft water
will  produce  clear  ice  cubes.
Cloudy  or  white, hazy  ice  cubes
are  caused  by  air  that  is  slowly
being  released  from  the  water
during the freezing process, which
has nothing to do with the perform-
ance of your system.

Содержание EC4 50 V

Страница 1: ...09 06 For use in California RainSoft Division of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 1 847 437 9400 or 1 800 860 7638 www rainsoft com EC4 SERIES WAT...

Страница 2: ...ntenance Requirements 7 Product Certification Information 7 Installation Instructions 8_11 System Start Up 12 Customer Settings 13_14 How to Initiate a Manual Regeneration 14 System Alarms 15 Understa...

Страница 3: ...individual water consumption needs Application Limitations On hardness levels of 60 grains and higher the system may not achieve a hardness of less than 1 grain due to high Total Dissolved Solids some...

Страница 4: ...s system is designed to treat cold water only The installation must be on a cold water supply Data Chart for ION X 2000 V Resin Cation Exchange Media The conditioners are efficiency rated according to...

Страница 5: ...gpm psi Drop High Salting Medium Salting Low Salting Efficiency EC4 50 T 8 x 44 0 5 10 0 1 5 12 0 12 600 7 5 lbs 10 000 5 0 lbs 5 800 2 0 lbs n a EC4 50 CT 8 x 44 0 5 10 0 1 5 13 0 12 600 7 5 lbs 10 0...

Страница 6: ...x 44 1 0 10 0 2 0 10 0 29 400 15 0 lbs 23 900 10 0 lbs 10 900 3 0 lbs 3 630 3 0 lbs EC4 100S D 10 x 35 1 0 10 0 2 0 10 0 29 400 15 0 lbs 23 900 10 0 lbs 10 900 3 0 lbs 3 630 3 0 lbs EC4 100S CD 10 x 3...

Страница 7: ...ication Information The EC4 Series is tested and certified by the WQA to NSF ANSI Standard 44 for the specific performance claims as verified and substantiated by test data Please refer to the perform...

Страница 8: ...ove the cap plug from the tank Lubricate the riser pipe o ring and tank o ring with the proper silicone lubricant Attach the supplied upper basket to the bottom of the control valve twist to lock in p...

Страница 9: ...system the inlet is the pipe connection on the right side of the valve see figure 2 The arrow molded into valve indicates the direction of flow Connect the treated water pipe to the outlet pipe connec...

Страница 10: ...e air gap must be installed between the end of the drain line and the drain to prevent possible back siphoning see figure 5 11 Install the Brine Safety Float Insert the brine well into the brine tank...

Страница 11: ...from the warranty pack Attach the U shaped connectors supplied to the wire with a crimping tool not supplied Connect the wire to the transformer see figure 8 Insert the other end of the wire with the...

Страница 12: ...es see figure 9 Open the bathtub faucet again and allow the system to fill with water for approximately 5 minutes After 5 minutes test for soft water 4 Flush the Hot Water Heater Run hot water in the...

Страница 13: ...he time of day only on the hour that the computer will regenerate the system based on the parameters set To access these programming options please follow the directions listed below If the display is...

Страница 14: ...eration To exit the Customer Settings press the Enter key How to Initiate a Manual Regeneration If the display is not lit press any key to begin When the display is lit press the Manual Regen key The...

Страница 15: ...Use Displays the average water use of the system in gallons per day Avg Weekly Salt Used Displays the average weekly salt used in pounds Current Flow Rate Displays the flow rate through the system wh...

Страница 16: ...ion is complete 2 The system regenerates at the wrong time 1 The raw water has changed 2 The bypass valve is open 3 The power supply is disconnected 3 Plug in the power supply 1 Call your RainSoft Dea...

Страница 17: ...y does not include labor charges and does not cover installation transportation or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential damages...

Страница 18: ...18 Valve Exploded View 13 16 17 26 ABCDE 18 20 21 19 30 3 B A 31 12 11 28 15 14 29 32 1 10 2 6 23 ABC 27 25 4 5 7 24 22 9 8...

Страница 19: ...54 Flow control washer 0 25 gpm 21 1 17957 Adapter blfc 0 25 gpm 22 1 17939 1 2 npt x 1 2 barb poly elbow 23 1 17557 Composite bypass valve 24A 1 17560 3 4 coupling adapter assembly 24B 1 17558 Turbin...

Страница 20: ...Control Exploded View 20 7 5A 6 1 2 3 4 8 9 10 8 11 12 8 5B 5C A B...

Страница 21: ...male connector red outdoor 5C 2 19537 Sealed switch C NO female connector brown outdoor 6 2 17548 10 32 x 1 50 screw pan h phil ss 7 2 18135 4 x 1 25 screw slotted hex washer type 25 8 5 17542 4 20 x...

Страница 22: ...E 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 470 GRAINS LBS SALT 3 0 LBS DOSAGE LIST OF CONTAMINANTS REDUCED CAPACITY SALT 13 400 GRAINS 3 0...

Страница 23: ...r Treatment Products The water treatment device s listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related...

Страница 24: ...E 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 970 GRAINS LBS SALT 3 0 LBS DOSAGE LIST OF CONTAMINANTS REDUCED CAPACITY SALT 14 900 GRAINS 3 0...

Страница 25: ...116830 of the Health and Safety Code for the following health related contaminants None Barium Radium 226 228 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organi...

Страница 26: ...E 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 970 GRAINS LBS SALT 4 5 LBS DOSAGE LIST OF CONTAMINANTS REDUCED CAPACITY SALT 22 400 GRAINS 4 5...

Страница 27: ...116830 of the Health and Safety Code for the following health related contaminants None Barium Radium 226 228 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organi...

Страница 28: ...DOSAGE LIST OF CONTAMINANTS REDUCED CAPACITY SALT 10 700 GRAINS 2 4 LBS OF SALT 19 200 GRAINS 6 0 LBS OF SALT 22 500 GRAINS 9 0 LBS OF SALT HARDNESS WAS USED AS A SURROGATE FOR BARIUM AND RADIUM REDUC...

Страница 29: ...116830 of the Health and Safety Code for the following health related contaminants None Barium Radium 226 228 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organ...

Страница 30: ...TURE 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 970 GRAINS LBS SALT 3 0 LBS DOSAGE LIST OF CONTAMINANTS REDUCED CAPACITY SALT 14 900 GRAINS 3...

Страница 31: ...116830 of the Health and Safety Code for the following health related contaminants None Barium Radium 226 228 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organi...

Страница 32: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2006 RAINSOFT DIVISION...

Отзывы: