Rainman RO Скачать руководство пользователя страница 2

2/5

1. Cut the two black straps that mount the

pressure vessels into the case. Leave the
two inner straps intact as that holds the RO
pressure vessel assembly together.

2. Grasping one of the remaining straps and

with the other hand bending the side of the
case outwards, pull one end of the RO
assembly out of the case. This allows you
to easily remove the entire RO internals.

3. Using 16mm spanner

loosen the nut which
holds a stainless pipe in
place. It may be useful to
use a second spanner as
shown to prevent end cap
rotation.

4. Firmly pull the hook 3-4 centimeters (1-

1.5”) out, and push it left and down just
enough so it does not block the way while
removing the end cap from RO housing.
Note: this will shift the whole blue plastic
“spine” that separates the two pressure
vessels.