CLEANING THE GENERATOR

It is important to inspect and clean the generator before 

every use.

Clean All Engine Air Inlet and Outlet Ports

 – Make 

sure all engine air inlet and outlet ports are clean of any 

dirt and debris to ensure the engine does not run hot.

Clean All Engine Cooling Fins 

– Use a damp rag and

a brush to loosen and remove all dirt on or around the 

engine’s cooling fins.

Clean All Alternator Cooling Air Inlets and Exhaust

Ports

 – Make sure the cooling air inlets and exhaust 

ports of the alternator are free of any debris and ob-

structions. Use a vacuum cleaner to remove dirt and 

debris stuck in the cooling air inlets and exhaust ports.

General Cleaning of the Generator

 – Use a damp rag 

to clean all remaining surfaces.

 

STORING GENERATOR

WARNING

Never store a generator with fuel in the tank indoors 

or in a poorly ventilated area where the fumes can 

come in contact with an ignition source such as a: 

1) pilot light of a stove, water heater, clothes dryer or 

any other gas appliance; or 2) spark from an electric 

appliance.

NOTICE

Gasoline stored for as little as 60 days can go bad, causing gum, 

varnish and corrosive buildup in fuel lines, fuel passages and the 

engine. This corrosive buildup restricts the flow of fuel, preventing an 

engine from starting after a prolonged storage period.

Proper care should be taken to prepare the generator for 

any storage.
1.  Make sure the Engine Switch is switched to 

STOP

 

so the generator does not draw power from battery. 

2.  Clean the generator as outlined in 

Cleaning the 

Generator

.

3.  Drain all gasoline from the fuel tank as best as 

possible.

4.  Drain fuel out of carburetor bowl by loosening screw.

fuel pan

CHECKING AND ADJUSTING VALVE LASH

CAUTION

Checking and adjusting valve lash

must be done when the engine is cold.

1.  Remove the rocker arm cover and carefully remove the 

gasket. If the gasket is torn or damaged, it must be 

replaced.

2.  Remove the spark plug so the engine can be rotated more 

easily.

3.  Rotate the engine to top dead center (TDC) of the 

compression stroke. Looking through the spark plug hole, 

the piston should be at the top.

4.  Both the rocker arms should be loose at TDC on the 

compression stroke. If they are not, rotate the engine 360°.

5.  Insert a feeler gauge between the rocker arm and the push 

rod and check for clearance. See Table 3 for valve lash 

specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Push Rod, (2) Feeler Gauge Area 

(3) Rocker Arm,  (4) Jam Nut, (5) Adjusting Nut

(Table 3) Standard Valve Lash

Intake Valve

Exhaust Valve

Valve Lash

0.0035 ± 0.0043 in

 

(0.09 ± 0.11 mm)

0.0043 ± 0.0051 in

 

(0.11 ± 0.13 mm)

Bolt Torque

8-12N.m

8-12N.m

6.  If an adjustment is required, hold the adjusting nut and 

loosen the jam nut.

7.  Turn the adjusting nut to obtain the correct valve lash. 

When the valve lash is correct, hold the adjusting nut and 

tighten the jam nut to 106 in-lb (12 N•m).

8.  Recheck the valve lash after tightening the jam nut.
9.  Perform this procedure for both the intake and exhaust 

valves.

10.  Install the rocker arm cover, gasket and spark plug.

1

2

3

4

5

MAINTENANCE

Содержание HYBRID DUAL FUEL R4400DF

Страница 1: ...R4400DF Dual Fuel OPEN FRAME Generator GASOLINE 3600 Running Watts 4400 Peak Watts PROPANE 3300 Running Watts 4000 Peak Watts...

Страница 2: ...n cause you and others to be seriously hurt or killed Model Number Running Watts Peak Watts Gasoline Tank Size G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity qt O...

Страница 3: ...register your generator you will need to locate the following information RAINIER PRODUCT REGISTRATION FORM PERSONAL INFORMATION GENERATOR INFORMATION First Name _____________________________________...

Страница 4: ...ction 13 Grounding the Generator 13 High Altitude Operation 13 Power Cord 14 Engine Fluids and Fuel 15 Adding Gasoline to the Fuel Tank 15 Connecting LPG Tank 16 Switching Fuel Sources 17 Starting the...

Страница 5: ...NGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CA...

Страница 6: ...ap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with gasoline Keep sparks...

Страница 7: ...sive and flammable Explosions and fire can cause severe burns or death Gasoline and gasoline vapor Gas Gasoline is highly flammable and explosive Gas expands and contracts with different temperatures...

Страница 8: ...ALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other soft material to tip the generator onto to protect the frame paint and prevent the generator from sliding...

Страница 9: ...tery cables ALWAYS disconnect the negative battery cable black boot first when disconnecting battery cables NEVER connect the negative battery cable black boot to the positive post on the battery NEVE...

Страница 10: ...tick Must be removed to add and check oil FEATURES Oil Drain Plug Must be removed to drain engine oil Propane Hook Up Hook up your propane tank with the LPG hose provided to this inlet Never Flat Whee...

Страница 11: ...ervicing the engine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sp...

Страница 12: ...s used to ground the generator 20 Amp Circuit Breaker Circuit breaker limits the current that can be delivered through the 120 volt duplex outlets to 20amps Fuel Selector Switch Select and turn on gas...

Страница 13: ...electrical shock due to faulty appliances High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced approximately 3 5 for every 1000ft of increased...

Страница 14: ...the responsibility of the user only This table is intended for reference only The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and...

Страница 15: ...intain the proper oil level can result in engine damage NOTICE During the first five hours of operating the generator make sure to not exceed 50 of the rated running watts until the unit is broken in...

Страница 16: ...G hose when not in use OPERATION BEFORE STARTING THE GENERATOR BEFORE STARTING THE GENERATOR REVIEW SAFETY SECTION STARTING ON PAGE 5 Before attempting to start the generator verify the following The...

Страница 17: ...rt up FOR GASOLINE a Move the fuel shut off valve to the ON position ON OFF b Turn fuel selector knob to GASOLINE Fuel Shut Off ON Fuel Selector GASOLINE FOR LPG PROPANE a Make sure the LPG hose is sa...

Страница 18: ...the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin Allow engine oil to cool for several minutes before removing the oil fill plug dipstick Always p...

Страница 19: ...Change Cooling Features Check Clean Air Filter Check Clean Replace Spark Plug Check Clean Replace Spark Arrestor Check Clean Service more frequently if operating in dry and dusty conditions TABLE 2 M...

Страница 20: ...ize 4 With a damp rag clean around the oil fill plug dipstick 5 Remove oil fill plug dipstick Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick an...

Страница 21: ...ities or reclamation facility AIR FILTER MAINTENANCE WARNING Never use gasoline or other flammable solvents to clean the air filter Use only household detergent soap to clean the air filter Cleaning t...

Страница 22: ...plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug Applying a...

Страница 23: ...Switch is switched to STOP so the generator does not draw power from battery 2 Clean the generator as outlined in Cleaning the Generator 3 Drain all gasoline from the fuel tank as best as possible 4 D...

Страница 24: ...ck for overload condition 2 The power cord s plug connector is not fully engaged in the generator s outlet 2 Verify plug connector is firmly engaged in the generator s outlet 3 Faulty or defective pow...

Страница 25: ...buretor dispersing after operation 3 Normal no remedy is needed Poor performance or engine stalling on propane 1 Propane fuel line kinked or crushed 1 Inspect propane fuel line and remove kinks or oth...

Страница 26: ...ou must at your expense deliver or ship your Rainier generator to an Rainier Outdoor Power Equipment Authorized Service Dealer for warranty repairs which must occur within the applicable warranty peri...

Страница 27: ...rtime holiday or emergency labor Starting battery fuses light bulbs and engine fluids DISCLAIMER OF IMPLIED WARRANTIES This limited warranty is in lieu of all other expressed or implied warranties inc...

Страница 28: ...28 Version 07 05 18KD Rev2 RainierPower com...

Отзывы: