![RainFlo 36667 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/rainflo/36667/36667_user-manual_3450871008.webp)
6
8. TROUBLESHOOTING
Pulsating Flow - Pump Cycles On and Off
•
Check line for kinks.
•
Plumbing lines or fittings may be too small.
•
Clean faucets and filters.
•
Check all fittings for air leaks and tighten as needed.
Noisy
•
Check if the mounting feet are compressed too tightly.
•
If the mounting surface is flexible, it may be adding noise.
•
Check for loose head/screws.
•
If the pump is plumbed with rigid pipe, then it may transmit noise
more easily.
Failure to Prime but Motor Operates - No Pump Discharge
•
Restricted intake or discharge line.
•
Air leak in the intake line.
•
Punctured pump diaphragm.
•
Initial amp supply is not enough to sufficiently start the motor.
•
Debris clogged in the valves.
•
Crack in pump housing.
Motor Fails to Turn On
•
Loose or improper wiring.
•
Pump circuit has no power.
•
Blown fuse or thermal protection tripped.
•
Failed pressure switch.
•
Defective motor.
Pump Fails to Turn Off After All Fixtures are Closed
•
Punctured diaphragm.
•
Discharge line leak.
•
Defective pressure switch.
•
Insufficient voltage.
•
Clogged valves in pump head.
Low Flow and Pressure
•
Air leak at pump intake.
•
Accumulation of debris inside pump or plumbing.
•
Worn pump bearing (possibly accompanied by loud noise).
•
Punctured diaphragm.
•
Defective motor.
Содержание 36667
Страница 1: ...12V 24V Diaphragm Pumps USER MANUAL...
Страница 2: ...It is the installer s responsibility to read understand and comply with these instructions...
Страница 10: ...8...
Страница 11: ...9...
Страница 12: ...RainHarvest Systems RainHarvest com 800 654 9283 092121...