RainFlo 36667 Скачать руководство пользователя страница 8

6

8. TROUBLESHOOTING

Pulsating Flow - Pump Cycles On and Off

• 

Check line for kinks.

• 

Plumbing lines or fittings may be too small.

• 

Clean faucets and filters.

• 

Check all fittings for air leaks and tighten as needed.

Noisy

• 

Check if the mounting feet are compressed too tightly.

• 

If the mounting surface is flexible, it may be adding noise.

• 

Check for loose head/screws.

• 

If the pump is plumbed with rigid pipe, then it may transmit noise 
more easily. 

Failure to Prime but Motor Operates - No Pump Discharge

• 

Restricted intake or discharge line.

• 

Air leak in the intake line.

• 

Punctured pump diaphragm.

• 

Initial amp supply is not enough to sufficiently start the motor.

• 

Debris clogged in the valves.

• 

Crack in pump housing.

Motor Fails to Turn On

• 

Loose or improper wiring.

• 

Pump circuit has no power.

• 

Blown fuse or thermal protection tripped.

• 

Failed pressure switch.

• 

Defective motor.

Pump Fails to Turn Off After All Fixtures are Closed

• 

Punctured diaphragm.

• 

Discharge line leak.

• 

Defective pressure switch.

• 

Insufficient voltage.

• 

Clogged valves in pump head.

Low Flow and Pressure

• 

Air leak at pump intake.

• 

Accumulation of debris inside pump or plumbing.

• 

Worn pump bearing (possibly accompanied by loud noise).

• 

Punctured diaphragm.

• 

Defective motor.

Содержание 36667

Страница 1: ...12V 24V Diaphragm Pumps USER MANUAL...

Страница 2: ...It is the installer s responsibility to read understand and comply with these instructions...

Страница 3: ...tch 1 FEATURES 4 chamber diaphragm pump Continuous duty Bypass reduces cycling Self priming Quiet operation Ignition protected Run dry capable for normal workloads Automatic controlled by pres sure sw...

Страница 4: ...ts no smaller than 10 mm 4 Plumb the system using high pressure 2 x pump rating braided flexible tubing to minimize vibration noise 5 Do not apply inlet pressure in excess of 30 PSI In general try to...

Страница 5: ...rovid ed plastic fittings 3 Do not adjust the bypass without the help of a technician 4 Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump Please perform ma...

Страница 6: ...Leads 16 AWG 9 4 in 24 cm long with 2 pin connec tor leads Duty Cycle Intermittent Max Amp Draw 7 00A 12V 3 37A 24V Fuse 10A 12V 5A 24V Standard Pump Configuration Part Numbers Voltage Open Flow Contr...

Страница 7: ...WG 0 20 16 AWG 20 30 14 AWG 30 50 12 AWG 50 65 10 AWG 7 REPAIR KITS Key Description Quantity A Pump Head Assembly 1 B Valve Assembly 1 C Diaphragm Assembly 1 D Motor Assembly 1 1 Pressure Switch 1 2 D...

Страница 8: ...take or discharge line Air leak in the intake line Punctured pump diaphragm Initial amp supply is not enough to sufficiently start the motor Debris clogged in the valves Crack in pump housing Motor Fa...

Страница 9: ...letely mark the screw in relation to the bypass housing for reference as to number of turns start screwing the set screw clockwise 10 to 11 turns See Picture 2 Note 3 This will increase the maximum by...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...RainHarvest Systems RainHarvest com 800 654 9283 092121...

Отзывы: