5. SPECIFICATIONS

Pump

Type

4 chamber positive displacement diaphragm 
pump, self priming, capable of being run dry

Control Type

Pressure switch and bypass control

Max Recommended 

Temperature

140°F (60°C)

Priming Capabilities

6 ft. (1.8m) suction lift

Re-start Pressure

Shut-off pressure 55 PSI : 41 PSI ± 5 PSI (±0.3 

bar)

Inlet/Outlet Ports

1/2"-14 MNPT

Weight

4.0 lbs. (1.9 kg)

Motor

Leads

16 AWG, 9.4 in. (24 cm) long with 2-pin connec-
tor/leads

Duty Cycle

Intermittent

Max. Amp Draw

7.00A(12V)/3.37A(24V)

Fuse

10A(12V)/5A(24V)

Standard Pump Configuration

Part 

Numbers

Voltage

Open Flow

Control 

Type

Max Draw

36667/ 

36674

12V/24V

3.0 GPM

 

(11.3 LPM)

Switch and 

bypass

7.00A/3.37A

Shut-off 

Pressure

Valves

Diaphragm

Ports

Wire 

Connections

55 PSI 

(3.8 bar)

EPDM

Santoprene

1/2”-14 

MNPT

2-pin/leads

Performance

Pressure

Flow

Current (Amps)

PSI

Bar

GPM

LPM

12V

24V

0

0.00

2.85

10.80

3.9

1.15

10

0.69

2.27

8.60

4.5

1.84

20

1.38

1.96

7.40

5.1

2.24

30

2.07

1.59

6.00

5.8

2.64

Содержание 36667

Страница 1: ...12V 24V Diaphragm Pumps USER MANUAL...

Страница 2: ...It is the installer s responsibility to read understand and comply with these instructions...

Страница 3: ...tch 1 FEATURES 4 chamber diaphragm pump Continuous duty Bypass reduces cycling Self priming Quiet operation Ignition protected Run dry capable for normal workloads Automatic controlled by pres sure sw...

Страница 4: ...ts no smaller than 10 mm 4 Plumb the system using high pressure 2 x pump rating braided flexible tubing to minimize vibration noise 5 Do not apply inlet pressure in excess of 30 PSI In general try to...

Страница 5: ...rovid ed plastic fittings 3 Do not adjust the bypass without the help of a technician 4 Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump Please perform ma...

Страница 6: ...Leads 16 AWG 9 4 in 24 cm long with 2 pin connec tor leads Duty Cycle Intermittent Max Amp Draw 7 00A 12V 3 37A 24V Fuse 10A 12V 5A 24V Standard Pump Configuration Part Numbers Voltage Open Flow Contr...

Страница 7: ...WG 0 20 16 AWG 20 30 14 AWG 30 50 12 AWG 50 65 10 AWG 7 REPAIR KITS Key Description Quantity A Pump Head Assembly 1 B Valve Assembly 1 C Diaphragm Assembly 1 D Motor Assembly 1 1 Pressure Switch 1 2 D...

Страница 8: ...take or discharge line Air leak in the intake line Punctured pump diaphragm Initial amp supply is not enough to sufficiently start the motor Debris clogged in the valves Crack in pump housing Motor Fa...

Страница 9: ...letely mark the screw in relation to the bypass housing for reference as to number of turns start screwing the set screw clockwise 10 to 11 turns See Picture 2 Note 3 This will increase the maximum by...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...RainHarvest Systems RainHarvest com 800 654 9283 092121...

Отзывы: