Section 3 – Operating Instructions
10
3.4 Chemflo Flow Rates
The flow rate of the
Chemflo
is varied using a duty cycle, so for most of the time the pump does
not operate. For example, the pump will be ON for 2.5 minutes per 15 minute cycle when it is set to
99. When the unit is set to 50, the pump will be ON for half the time, i.e. 1.25 minutes per 15
minute cycle. Refer to the table below.
The only time that the pump operates continuously is when the control is set to FULL.
Flow Rates of Dosing Pump when control set to
99
Tube Size
Rate per Hour
Rate per Day 8 hrs* Duty Cycle
Small Tube
300 mL/Hr
2400 mL/Day
2.5 mins ON per 15 mins
Large Tube
1000 mL/Hr
8000 mL/Day
2.5 mins ON per 15 mins
* Based on 8 hour pump operation for each day.
Flow Rates of Dosing Pump when control set to
FULL
Small Tube
1.8 L/hr
Large Tube
6.1 L/Hr
Flow rates were measured pumping into a pool line at 50 kPa.