Inst.300 Viron EVO Pool & Spa Pump V01_12
11
Data cable connector:
If a compatible AstralPool VX Salt Chlorinator, Viron Salt Chlorinator or Viron Connect Touch Screen, is connected
with the AstralPool communication cable, the speed of the pump and operating hours can be controlled by these
devices.
The Viron P320 & P600 eVo must have its inbuilt timer deactivated if the pump operating times and speeds are to
be operated by the compatible AstralPool Salt Chlorinator, RolaChem Dosing Controller or Viron Connect remote
touch screen.
Remove 2 philips head screens from rear of pump and the data port cover is removed by hand. Plug RJ12 6 wire
flat cable purchased from AstralPool into rear of pump and reassemble. To achieve a proper seal, press the flat
cable under the guide tabs (detailed view A). Slide data port cover back on by aligning the tabs with the slots and
the flat cable with the recess (detailedl view B).
REMOTE CONTROL OF SPEEDS AND TIMER FUNCTIONS
•
Viron eVo pump stand alone
•
4 built in timer periods in pump
•
3 programmable speed settings
•
Low, medium or high speed can be selected in each timer period
•
Priming period can be selected from 2 to 120 minutes
•
Prime RPM can be selected from 1275 to 2850 RPM
240v power
24v comms data