Rain Soft TC Series Скачать руководство пользователя страница 3

3

Congratulations

on  your  purchase  of  a  RainSoft  water  treatment

system.

This Owner’s Manual is designed to assist with the operation, mainte-
nance,  and  installation  of  your  water  treatment  system.  It  is  our
sincere hope that this manual is clear, concise, and helpful to you as a
new owner.

Questions? 

If you have any questions regarding the installation, oper-

ation,  or  servicing  of  this  system,  please  contact  your  local  RainSoft
Dealer.  Your  local  RainSoft  Dealer  is  familiar  with  your  particular
water conditions, and is able to address your concerns promptly and
efficiently.

Information on Water Treatment
Systems

There are many misconceptions that have been developed about water
treatment  systems.  The  most  common  topic  of  confusion  is  the
amount  of  sodium  (Na),  not  table  salt  (NaCl),  that  is  added  to  the
water from a water conditioner. In reality, ion exchange does replace
the hardness ions in your water with sodium ions, but the common
misconception is the amount used.

For  every  1  grain  of  hardness,  the  exchange  process  will  deliver
approximately  8  milligrams  of  sodium  per  1  liter  of  water.  The
amount of sodium present in a standard 8 ounce glass of treated water,
that  was  10  grains  hard  prior  to  treatment,  would  be  around  19
milligrams  of  sodium.  This  is  an  insignificant  amount  of  sodium
considering a typical slice of white bread has about 140 milligrams.

Another  common  misconception  that  needs  mentioning  is  the
amount of salt used by the conditioner to regenerate the system. In the
past, water conditioners used more salt to regenerate, but that was due
to  old  technology  and  standards.  Water  conditioners  do  use  salt  for
regeneration, but the amount of salt varies by water consumption and
hardness levels. Fortunately, today’s technology allows us to dispense
just the right amount of salt for maximum efficiency, based on your
individual water consumption needs.

Application Limitations

• On  hardness  levels  of  60  grains  and  higher,  the  system  may  not

  achieve a hardness of less than 1 grain; due to high Total Dissolved
  Solids,  some  bleed  through  is  possible.  Bleed  through  can  also  be
  caused by sodium levels higher than 1000 parts per million. In either
  case, your system can be programmed to minimize these effects. See
  your RainSoft Dealer for details.

• Chlorine or Chloramine levels on municipality treated water should

  not exceed 4 parts per million.

*

When Chlorine or Chloramine 

  levels are 4 parts per million

*

or greater, it can have adverse effects 

  on your system. In applications where high levels are a concern,
  pre-filtration is necessary to reduce the Chlorine or Chloramine 
  to an acceptable level. See your RainSoft Dealer for details.

• When this system is installed on water with Ferrous iron, 

  also known as clear water iron, the maximum range of removal 
  is based on local water conditions. The range is generally 2 to 10 
  parts per million. Your equipment may require special 
  programming, along with an additive to the brine tank, to 
  maximize the equipment’s ability to remove iron. See your RainSoft
  Dealer for details.

Important Note: Iron fouled resin
is not eligible for warranty
replacement.

The amount of iron reduced by
your conditioner is based on the
incoming pH.  Consult your local
RainSoft dealer for more details.

Important Note: This system may
be installed on well water or
municipality treated water
supplies.

Important Note: Most municipality
treated water supplies contain
Chlorine as a disinfectant. Many
municipalities also inject
ammonia into the water supply,
creating Chloramine.

Maximum disinfectant level of
Chlorine or Chloramine recom-
mended from the EPA.

*

Helpful  Tip:  Another  common
misconception  of  water  treatment
systems is the idea that soft water
will  produce  clear  ice  cubes.
Cloudy  or  white,  hazy  ice  cubes
are  caused  by  air  that  is  slowly
being  released  from  the  water
during the freezing process, which
has nothing to do with the perform-
ance of your system.

Содержание TC Series

Страница 1: ...specific reduction claims Part No 16618 Rev H 05 16 The TC series is tested and certified by the WQA to NSF ANSI 372 for lead free Compliance The TC series is tested and certified by the WQA to CSA B4...

Страница 2: ...rs 7 Maintenance Requirements 7 Product Certification Information 7 Installation Instructions 8_11 System Start Up 12 Customer Settings 13 Installers Section 14 15 How to Calculate the Regeneration Sc...

Страница 3: ...water consumption needs Application Limitations On hardness levels of 60 grains and higher the system may not achieve a hardness of less than 1 grain due to high Total Dissolved Solids some bleed thr...

Страница 4: ...ust be adequate for easy service and accessibility This system is designed to treat cold water only The installation must be on a cold water supply Data Chart for ION X 2000 V Resin Cation Exchange Me...

Страница 5: ...inches Resin cu ft Service Flow gpm Drain Flow gpm psi Drop High Salting Medium Salting Low Salting TC 50 T 8 x 44 0 5 10 1 6 12 0 10 800 7 5 lbs 9 200 5 0 lbs 4 400 1 5 lbs TC 50 CT 8 x 44 0 5 10 1 5...

Страница 6: ...8 lbs TC 75 D 8 x 44 0 75 8 8 1 5 15 0 26 100 11 2 lbs 21 300 7 5 lbs 9 900 2 25 lbs TC 75 CD 8 x 44 0 75 9 2 1 5 14 0 26 100 11 2 lbs 21 300 7 5 lbs 9 900 2 25 lbs TC 100 D 10 x 44 1 0 10 0 2 0 10 0...

Страница 7: ...from RainSoft Please call 1 800 860 7638 for your free two year supply In between testing you can easily monitor the system s performance in the shower or while washing your hands The feeling of soft...

Страница 8: ...with Dow 111 silicone based lubricant or equivalent Attach the supplied upper basket to the bottom of the control valve twist to lock in place Do not use if water contains any amount of iron Align th...

Страница 9: ...is the pipe connection on the left side of the valve see figure 2 The arrow molded into the valve indicates the direction of flow When installing on metallic plumbing connect grounding pipe clamp and...

Страница 10: ...the drain to prevent possible back siphoning see figure 5 11 Install the Brine Safety Float Insert the brine well into the brine tank see figure 6 Attach the brine well to the brine tank with the over...

Страница 11: ...erminals on the transformer see figure 8 Insert the other end of the wire with the quick connector into the back of the control box see figure 8 Plug the transformer into a 110 VAC 60 Hz or 230 VAC 50...

Страница 12: ...again and allow the system to flush for 20 minutes or until approximately 100 gallons has passed through the appliance 4 Flush the Hot Water Heater Run hot water in the bathtub until the water tests s...

Страница 13: ...een regeneration icon will begin to flash use the up or down arrows to adjust the days between regeneration Press the Menu Scroll button two times to exit Setting pounds of salt From the home screen p...

Страница 14: ...models 100 and all V 2000 Once this is done press the Menu Scroll button 4 times to advance past the backwash time Brine and rinse time and fast rinse The display will rapidly flash save changes and...

Страница 15: ...s by the number of people in the home use 4 in this example Example 75 gallons x 4 people 300 gallons used per day 2 Calculate the Number of Grains to be Softened Per Day Use the number of gallons use...

Страница 16: ...s valve 3 Plug in the power supply 4 Loss of water pressure 1 Low pressure to the unit 1 Bypass the system If the problem still exists after bypass it is not related to a RainSoft product Check your w...

Страница 17: ...warranty does not include labor charges and does not cover installation transportation or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential...

Страница 18: ...18 18 Valve Exploded View...

Страница 19: ...iner blfc button 20 1 17954 Flow control washer 0 25 gpm 21 1 17957 Adapter blfc 0 25 gpm 22 1 17939 1 2 npt x 1 2 barb poly elbow 23 1 17557 Composite bypass valve 24 1 17560 3 4 coupling adapter ass...

Страница 20: ...20 Control Exploded View 20...

Страница 21: ...C NC male connector red outdoor 5B 1 19537 Sealed switch C NO female connector brown outdoor 6 3 17548 10 32 x 1 50 screw pan h phil ss 7 2 18135 4 x 1 25 screw slotted hex washer type 25 8 7 17542 4...

Страница 22: ...ler ___________________________________ Name __________________________________Name __________________________________ Address ________________________________Address ________________________________...

Страница 23: ...23 Notes...

Страница 24: ...RainSoft Division of Aquion Inc 101 S Gary Ave Roselle Illinois 60172 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2011 RAINSOFT DIVISION OF AQUION INC...

Страница 25: ...OPIETARIO MANUAL DE PROPIETARIO ACONDICIONADOR SERIE TC SISTEMA DE TRATAMIENTO DE AGUA La serie TC est probada y certificada por la WQA en NSF ANSI 44 para las afirmaciones espec ficas de rendimiento...

Страница 26: ...sitos de mantenimiento 32 Informaci n sobre la certificaci n del producto 32 Instrucciones de instalaci n 32 37 Arranque del sistema 37 Opciones del cliente 38 Secci n del instalador 39 41 C mo calcul...

Страница 27: ...n el consumo de agua y los niveles de dureza Afortunadamente la tecnolog a actual nos permite utilizar la cantidad necesaria de sal para lograr la m xima eficiencia basada en sus necesi dades individu...

Страница 28: ...istentes La tuber a debe estar libre de cal y o acumulaci n de hierro La tuber a que contiene grandes cantidades de cal y o hierro debe ser reemplazada Especificaciones adicionales No instalar este si...

Страница 29: ...5 lbs 9 900 2 25 lbs TC 100 V 10 x 44 1 0 10 0 2 3 10 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs TC 100 CV 10 x 44 1 0 10 0 2 0 10 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs TC 100S V 10...

Страница 30: ...7 5 lbs 6 600 2 25 lbs TC 100 T 10 x 44 1 0 10 0 2 0 10 0 30 500 15 0 lbs 26 100 10 0 lbs 13 500 3 0 lbs TC 100 CT 10 x 44 1 0 10 0 2 0 11 0 30 500 15 0 lbs 26 100 10 0 lbs 13 500 3 0 lbs TC 100S T 10...

Страница 31: ...oxidantes fuertes por favor tenga cuidado y siga las instrucciones cuidadosa mente Modelo Tama o del tanque pulgadas Resina pies c bicos Flujo de Servicio gpm Flujo de drenaje gpm Ca da de psi Alta s...

Страница 32: ...ositivos de tratamiento de agua vendidos a los consumidores al por menor en California acompa ados de determinadas propiedades saludables deben estar certificados por el Departamento de Salud P blica...

Страница 33: ...r el sistema de tuber as abrir todos los grifos de la casa y tirar de la cadena El agua se drenar del grifo m s bajo o por la salida No sudar las tuber as con agua en ellas o mientras est conec tada a...

Страница 34: ...adera de tuber as de conexi n a tierra y los cables entre la entrada y la salida del tanque ver figura 2 9 Ajustar la v lvula de derivaci n para derivar Mover las manijas de la v lvula de derivaci n a...

Страница 35: ...do entre el final de la l nea de drenaje y el desag e para evitar el retorno del sif n ver la figura 5 11 Instalar el flotador de seguridad de salmuera Insertar el dep sito de salmuera en el tanque de...

Страница 36: ...seguridad de salmuera Utilizar un clip de fijaci n para asegurar la conexi n ver figura 7 13 Instalar la l nea de desbordamiento de salmuera Interior Ejecutar una l nea de desbordamiento de salmuera d...

Страница 37: ...s de colocar su aparato Rainsoft TC en servicio es muy importante vaciar los residuos las tuber as de agua fr a Abrir el grifo de agua fr a en la ba era Dejar correr el agua durante 5 a 10 minutos has...

Страница 38: ...eraci n Despu s que el sistema ha completado la regeneraci n manual el acondicionador estar desinfectado y listo para su utilizaci n Opciones del cliente Las opciones del cliente permiten el acceso a...

Страница 39: ...l bot n Menu Scroll antes de finalizar la cuenta regresiva Una vez la regeneraci n iniciada se podr de forma manual avanzar para cada ciclo mante niendo pulsado el bot n de Menu Scroll durante 5 segun...

Страница 40: ...tar en funci n del tama o del modelo S lo config urar estos valores en las aplicaciones que requieren una progra maci n especial El tiempo de llenado se ajustar autom ticamente al configurar las libra...

Страница 41: ...s al d a y multiplicar por los granos de dureza en cada gal n usar 10 en este ejemplo Agregar 5 granos para cada parte de Hierro 1 ppm 5 granos 2 ppm de hierro en este ejemplo Ejemplo 10 granos de dur...

Страница 42: ...esag e Revisar por torceduras en la l nea de drenaje Llamar a su distribuidor Rainsoft para el servicio 2 Llamar a su distribuidor Rainsoft para el servicio 3 Llamar a su distribuidor Rainsoft para ob...

Страница 43: ...luye los cargos de mano de obra no cubre la instalaci n el transporte o cualquier otro reclamo Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes por lo que par...

Страница 44: ...44 Vista despiezada de la v lvula...

Страница 45: ...olador del flujo del agua0 25 gpm 21 1 17957 Adaptador blfc 0 25 gpm 22 1 17939 Codo de la leng eta poly npt x 23 1 17557 V lvula de derivaci n compuesta 24 1 17560 Conjunto de adaptador de acoplamien...

Страница 46: ...46 Vista despiezada del control...

Страница 47: ...or sellado y conector macho rojo C NC exterior 5B 1 19537 Interruptor sellado y conector hembra marr n C NO exte 6 3 17548 Tornillo cabeza plana 10 32 x 1 50SS 7 2 18135 Tornillo hexagonal ranurado pa...

Страница 48: ..._________Vendedor__________________________________ Nombre_____________________________________Nombre____________________________________ Direcci n____________________________________Direcci n________...

Страница 49: ...49 Notas...

Страница 50: ...50 Notas...

Страница 51: ...51 Notas...

Страница 52: ...RainSoft Division of Aquion Inc 101 S Gary Avenue Roselle Illinois 60172 Principal panel de control 1 847 437 9400 Servicio al Cliente 1 800 860 7638 www rainsoft com 2013 RAINSOFT DIVISION OF AQUION...

Отзывы: