Maintenance Requirements

Replacing the Filter Cartridge

The  filter  cartridge  will  eventually  become  exhausted  or  consumed
and will need to be replaced. RainSoft replacement filter cartridges are
available  through  your  local  RainSoft  Dealer.  If  you  are  unable  to
order  replacement  parts  from  your  local  RainSoft  Dealer,  please
contact RainSoft at 1-800-860-7638 for assistance.

Testing Your Water

If you are relying on this system to reduce contaminants, we recom-
mend  testing  your  water  periodically  (2  times  a  year  minimum)  to
ensure  that  the  system  is  performing  properly.  Your  local  RainSoft
Dealer can arrange this testing for a nominal fee.

How to Change the Filters

1.   Turn off the cold water supply and open the system faucet to       

      relieve any line pressure. Remove Cover

2.   Place a drip pan or bucket if necessary to catch the water from the

       filter canisters to prevent spillage.

3.   To replace the filters, use a Slim Line Spanner Wrench (not 

      supplied)  unscrew the filter housings from the cap. (See Figure 8)

4.   Replace the filters and reassemble (See helpful tips).

5.   Turn on the inlet water to the Hydrefiner II system.

6.   Inspect system for any leaks, make the necessary repairs.

7.   Open Faucet. Allow the water in system to flush for 10 minutes.

8.   Replace cover.  

!

Important Note: We recommend replacing the
filter  cartridge  every  400  gallons.  Your
RainSoft Dealer can give you specific replace-
ment  schedules  based  on  your  water  usage
and incoming water quality.

Figure 8

Model

Pre-filter

Post-filter

HYDREFINER II-SC

51639

51845

!

Important Note: It is important to maintain the
quality  of  your  system  by  using  only  genuine
RainSoft replacement filters. Other “made-to-
fit”  alternative  filters  claim  to  perform  the
same duties as the original RainSoft parts, but
these  items  are  not  approved  for  use  in  your
system!  “Made-to-fit”  alternative  filters  will
increase the probability of leaks, putting your
entire  system  at  risk!  Also,  many  aftermarket
replacement  filters  are  not  tested  for  safe
contact with drinking water. 

When  “made-to-fit”  alternative  filters  are
placed  into  your  RainSoft  Hydrefiner  II
System, the product warranty will become null
and void and the system will lose its certifica-
tion. To guarantee proper operation and certi-
fication of your RainSoft Hydrefiner II System,
please use genuine RainSoft parts.

Helpful  Tips:  To  avoid  contamination,  we
recommend  the  use  of  sterile  gloves  while
changing the system components.

!

Important  Note:  When  Unscrewing  Filter
Housings  use  of  Slim  Line  Spanner  Wrench  is
required.  Unscrewing  filter  housings  with  use
of  other  unapproved  tools  can  damage  the
filter housings and void warranty.

!

Important  Note:  It  is  recommended  that  the
sump o-rings be replaced on each filter change
to  insure  proper  compression  of  the  o-ring.
Failure to do  so may result in over tightening
of  the  sump  to  create  a  seal  and  can  cause
undue  stress  on  the  sump  and  cap  that  can
lead  to  cracking  of  these  components  under
pressure.

7

Содержание Hydrefiner II

Страница 1: ...substantiated by test data See the performance data sheet for specific reduction claims RainSoft Hydrefiner II SC BNFP Hydrefiner II SC BNFV Hydrefiner II SC CHFP and Hydrefiner II SC CHFV are tested...

Страница 2: ...chase of one of the finest Drinking Water Systems available to homeowners This Owner s Manual is designed to assist with the installation operation and maintenance of the Hydrefiner II System It is ou...

Страница 3: ...stem is designed to treat cold water only The installation must be on a cold water supply Data Chart Product Certification Information RainSoft Hydrefiner II SC BNFP Hydrefiner II SC BNFV Hydrefiner I...

Страница 4: ...ll Filters and Secure Remove the filter assembly from the packaging Remove Sumps from INLET and OUTLET sides of the filter assembly Wearing sterile gloves remove the Sediment Filter from the packaging...

Страница 5: ...supplied between the outlet and the new faucet Connect the tubing to the ice maker 4 Connect the Inlet Shut Off Valve Not Supplied Use 3 8 inch OD tubing not supplied to connect the shut off valve to...

Страница 6: ...lush the System Open the new faucet and allow the water to flow for 10 minutes This process will flush the disinfectant and carbon fines from the system 4 Cover Assembly Place Cover onto Hydrefiner II...

Страница 7: ...fic replace ment schedules based on your water usage and incoming water quality Figure 8 Model Pre filter Post filter HYDREFINER II SC 51639 51845 Important Note It is important to maintain the qualit...

Страница 8: ...9 UF II 5 MICRON MELT BLOWN FILTER 6 2 12994 237 O RING 9516 7 2 51605 UF II SUMP SLIM LINE GRAY SPECKLES 8 4 71497 SCREW 10 16 BT X 1 IN 9 1 51366 UF II SUMP WATER WAY COUPLING 10 2 51367 UF II SUMP...

Страница 9: ...9 Exploded View 2 8 6 7 4 5 7 6 3 13 12 11 10 13 12 11 10 9 1 14 15...

Страница 10: ...Description 1 1 51609 CONTEMP PLUS B NICKEL FAUCET ASSY INCLUDES ITEM 2 51624 CONTEMP PLUS CHROME FAUCET ASSY INCLUDES ITEM 2 51616 CONTEMPORARY FAUCET B NICKEL ASSY INCLUDES ITEM 2 51603 CONTEMPORARY...

Страница 11: ...bacteria if present seek professional advice on proper well cleaning disinfection treatment If no iron sulfur bacteria are detected then treat the water for hydrogen sulfide reduction using an appropr...

Страница 12: ...on or limitation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rig...

Страница 13: ...13 Installer Specification Sheet Dealer Name Phone Number Installation Number Installation Date Model Number Serial Number Line Pressure psi...

Страница 14: ...ORE PURCHASING A WATER TREATMENT UNIT YOU HAVE YOUR WATER SUPPLY TEST ED TO DETERMINE YOUR ACTUAL WATER TREATMENT NEEDS CONTAMINANT INFLUENT CHAL LENGE CONCENTRA TION mg L REDUCTION REQUIREMENT PARTIC...

Страница 15: ...ot necessarily mean that these substances are present in your water supply This system is designed for treatment of cold water only Systems certified for cyst reduction may be used on disinfected wate...

Страница 16: ...RainSoft Division of Aquion Inc 101 S Gary Avenue Roselle Illinois 60172 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2014 RainSoft Division of AQUION INC...

Отзывы: