background image

----

9

Exploded View 

2

8

6

7

4

5

7

6

3

13

12

11

10

13

12

11

10

9

1

14

15

Содержание Hydrefiner II

Страница 1: ...substantiated by test data See the performance data sheet for specific reduction claims RainSoft Hydrefiner II SC BNFP Hydrefiner II SC BNFV Hydrefiner II SC CHFP and Hydrefiner II SC CHFV are tested...

Страница 2: ...chase of one of the finest Drinking Water Systems available to homeowners This Owner s Manual is designed to assist with the installation operation and maintenance of the Hydrefiner II System It is ou...

Страница 3: ...stem is designed to treat cold water only The installation must be on a cold water supply Data Chart Product Certification Information RainSoft Hydrefiner II SC BNFP Hydrefiner II SC BNFV Hydrefiner I...

Страница 4: ...ll Filters and Secure Remove the filter assembly from the packaging Remove Sumps from INLET and OUTLET sides of the filter assembly Wearing sterile gloves remove the Sediment Filter from the packaging...

Страница 5: ...supplied between the outlet and the new faucet Connect the tubing to the ice maker 4 Connect the Inlet Shut Off Valve Not Supplied Use 3 8 inch OD tubing not supplied to connect the shut off valve to...

Страница 6: ...lush the System Open the new faucet and allow the water to flow for 10 minutes This process will flush the disinfectant and carbon fines from the system 4 Cover Assembly Place Cover onto Hydrefiner II...

Страница 7: ...fic replace ment schedules based on your water usage and incoming water quality Figure 8 Model Pre filter Post filter HYDREFINER II SC 51639 51845 Important Note It is important to maintain the qualit...

Страница 8: ...9 UF II 5 MICRON MELT BLOWN FILTER 6 2 12994 237 O RING 9516 7 2 51605 UF II SUMP SLIM LINE GRAY SPECKLES 8 4 71497 SCREW 10 16 BT X 1 IN 9 1 51366 UF II SUMP WATER WAY COUPLING 10 2 51367 UF II SUMP...

Страница 9: ...9 Exploded View 2 8 6 7 4 5 7 6 3 13 12 11 10 13 12 11 10 9 1 14 15...

Страница 10: ...Description 1 1 51609 CONTEMP PLUS B NICKEL FAUCET ASSY INCLUDES ITEM 2 51624 CONTEMP PLUS CHROME FAUCET ASSY INCLUDES ITEM 2 51616 CONTEMPORARY FAUCET B NICKEL ASSY INCLUDES ITEM 2 51603 CONTEMPORARY...

Страница 11: ...bacteria if present seek professional advice on proper well cleaning disinfection treatment If no iron sulfur bacteria are detected then treat the water for hydrogen sulfide reduction using an appropr...

Страница 12: ...on or limitation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rig...

Страница 13: ...13 Installer Specification Sheet Dealer Name Phone Number Installation Number Installation Date Model Number Serial Number Line Pressure psi...

Страница 14: ...ORE PURCHASING A WATER TREATMENT UNIT YOU HAVE YOUR WATER SUPPLY TEST ED TO DETERMINE YOUR ACTUAL WATER TREATMENT NEEDS CONTAMINANT INFLUENT CHAL LENGE CONCENTRA TION mg L REDUCTION REQUIREMENT PARTIC...

Страница 15: ...ot necessarily mean that these substances are present in your water supply This system is designed for treatment of cold water only Systems certified for cyst reduction may be used on disinfected wate...

Страница 16: ...RainSoft Division of Aquion Inc 101 S Gary Avenue Roselle Illinois 60172 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2014 RainSoft Division of AQUION INC...

Отзывы: