background image

5. KEYPAD

A• Increase adjustment key
B• Decrease adjustment key
C• Program selection key (A, B or C)
D• Move to next function key-Validate-

Activate Field transmitter

E• Key to work within a function 

Set clock: set current day
Watering time per station: select station
Start times: move to next start time
Cancel start times

F• Infrared transmission key transmits

program to control module. The LCD
will display the low battery icon if TBOS
module battery must be replaced.

G• Key to display Module program.

The LCD will display the low battery icon if TBOS module battery
must be replaced.

GB

13

• Battery life: 1 season with 1 top grade 9V alkaline battery type

6AM6 (international standard) or type 6LR61 (European
standard): VARTA or equivalent (not included).

•Low battery indicator (transmitter and TBOS module). 

Storage and operational temperature: 0 to 55°C.

• Maximum system operating pressure: 10 bar.

!

6. INFRARED CORD DISASSEMBLY

Unplug the infrared cord by
pressing down the tab at the
top of the RJ9 connector and
gently pull it out.

F

G

A

E

D

C

B

• Automatic reset of current time and day when program is transmitted

to the control module.

• LCD automatically turns off after 1 minute if transmitter is not

being used.

Unscrew the battery
compartment cover 
and remove it

TBOS IR Anglais new der 5/11/04 15:20 Page 2

Содержание TBOS SYSTEM 6LR61

Страница 1: ...8 System on off 9 Now Transmitting 10 Transmission problem 11 Replace low battery inthetransmitteriftheiconappears when the key is pressed to turn on the LCD in the TBOS module if the icon appears dur...

Страница 2: ...odule battery must be replaced GB 13 Battery life 1 season with 1 top grade 9V alkaline battery type 6AM6 international standard or type 6LR61 European standard VARTA or equivalent not included Low ba...

Страница 3: ...and install it vertically above the cord slot Plug in the RJ9 connector on the Infrared cord Install the battery compartment cover and secure it 14 Remove the rubber plug from its location on the left...

Страница 4: ...rogram with the key Water days program Start times program Run time station program assignment of each station Irrigation mode On or Off The LCD will display the low battery icon if TBOS module batter...

Страница 5: ...ve it Install the battery Install the battery compartment cover and secure it 2 Set Clock 2 A Set current time of day AM PM Time Format If you want time displayed in AM PM hold down the ABC key for 2...

Страница 6: ...for shrubs and program C for trees Stations assigned to the same program operate sequentially 2 Option If you assign a station to each program with the same water days start times and run times you wi...

Страница 7: ...the program with the ABC key The program selected will appear on the screen as Prog followed by the letter A B or C Set the first start time with the ON and OFF keys Press the key to move on to the ne...

Страница 8: ...nts from 0 to 12 hours Each station must be assigned to a program Select the program with the ABC key Use the key to move to the next station Note If there is an overlap on the same station the 2nd st...

Страница 9: ...connected to each other The control module must be equipped with a fully charged 9V Alkaline battery Ref 6LR61 2 PROGRAM REVIEW AND CHANGE 2 1 Plug the field transmitter optical connector onto the con...

Страница 10: ...xample station 1 1 3 Repeatedly press the key until the desired station number appears 1 4 To start a station press the ON key Irrigation will start after 2 seconds after 10 seconds for Unik modules a...

Страница 11: ...the ON or OFF mode The only way to change the mode is by carrying out a manual ON OFF It is impossible to change the mode by just pressing the key on the transmitter To return to the irrigation mode r...

Отзывы: