english
13
TBOS
™
Field Transmitter
Note: The time display is represented in
hours and minutes. The first two place-
holders are for hours; the second two
placeholders are for minutes.
To set the run time:
1. Make certain the
H
icon is
visible on the display. If it is
not, press
B
repeatedly
to cycle through the menu
system and display the
H
icon.
2. The station number appears to the left of the run
time. Use
C
to select the station.
3. Press
A
repeatedly until the program you
desire (A, B, or C) flashes in the display (to the
right of the run time). Each station must be
assigned to a program (A, B, or C).
4. Use
O
and
P
to set the station run time.
5. Press
C
to move to the next station.
6. Repeat steps 3 through 5 until you have set all of
the station run times.
Note: If there is an overlap on the same
station, the second run time will not
take place.
7. When you have finished setting the run times,
you may review the run times by pressing
C
.
Erasing Field Transmitter programming data
To erase all program data in the Field Transmitter
(except the current time and day):
Press and hold
O
and
P
simultaneously for at
least three seconds.
All programming data are erased.
english
12
5. Repeat steps 3 and 4 until you have set all of the
start times you desire (up to eight per program)
for the program.
6. If you would like to set start times for additional
programs, press
A
until the program you
desire is displayed. Then repeat steps 3 and 4.
7. When you have finished setting the start times,
press
B
to move to the
H
icon, Setting the
Watering Time Length display.
Deleting a start time
To delete a start time:
1. Press
B
to advance to the
G
icon.
2. Press
A
to change to the appropriate program.
3. Press
C
to scroll through the start times until
the start time you want to delete is displayed.
(The start times will be in chronological order).
4. Press
O
or
P
until the blank position
(--:--) appears in the display. The blank position
is located between 11:59 and 12:00 (AM or PM).
5. Press
C
to scroll through the remaining start
times and confirm the deletion.
Setting the run time per station
You can set the run time for each station from 0 to 12
hours (in one minute increments). All One Station
Control Modules must be programmed on station 1.
Multi-station Control Modules (Two Station and
Four Station) must be programmed starting on sta-
tion 1. For example, on a Four Station Control
Module, programming would start on station 1, then
station 2, 3 and 4.
Note: Each station may be assigned to
only one program (A, B or C)! The sta-
tion will only respond to the start times
and days on for this program.