background image

7

NOTE:

 

On the RC-7 and -1260 series, the mini-

mum accumulated cycle time required to 

prevent

a second start within a given hour is 20 minutes.
Conversely, the maximum accumulated time to

permit

 a cycle start on a consecutive hour is 55

minutes. Total cycle time of more than one hour
is permissible.

NOTE:

 

It takes about 20 minutes for the hour

dial pin that started a watering cycle to move off
the cycle-start switch behind the face panel. To
make sure the RC-4C will not start another cycle
when the combined running time of stations 1
through 4 is less than 20 minutes, the controller
will stop at the non-existent station 6 position,
and time out 20 minutes before returning to

SEMI-AUTOMATIC OPERATION

The controller may be operated at any time in a semi-automatic mode simply by turn-
ing the STATION dial counterclockwise to position the desired station at the top, 

just

ahead

 of the Station pointer. Allow the automatic mechanism to advance into the de-

sired timing zone. The selected station will operate for the time set on the dial, after
which, the remaining stations will follow in sequence until the REST position again ap-
pears under the Station pointer.

RAIN SHUTDOWN

There may be occasions where it is desired to interrupt all landscape irrigation. Condi-
tions such as rainy weather, system repair, landscape renovation, or other excavation
work. The temporary shutdown of the system is accomplished by moving the MODE
switch to the OFF position. This eliminates controller output to the valves without inter-
rupting the controller timing circuitry. The controller will not operate either automati-
cally or semi-automatically.
A summary of the operating instructions is provided on the label inside the controller
door.

MAINTENANCE

The controller is designed to provide years of trouble-free service. The controller re-
quires no preventative maintenance or lubrication. Should trouble occur, refer to the
Troubleshooting chart for possible remedies, or contact your local authorized Rain
Bird dealer.

This completes the automatic setting of the controller. Move the MODE switch to the
AUTO position. The controller will now automatically control the landscape irrigation
according to the schedule.

Содержание RC-1260C

Страница 1: ...AL with 14 SCHEDULING PINS The calendar DAY dial contains 14 cap tive pins for scheduling irrigation everyday or any day within a two week range Each pin represents a 24 hour period beginning at midnight Embossed characters are on the dial adjacent to each day of the week C STATION SELECTOR INDICATOR DIAL The STATION selector indicator dial contains the timing controls for each of the stations The...

Страница 2: ...ill struggling with your old sprinkler timer Having a hard time complying with local watering restrictions Upgrading to a new Rain Bird sprinkler timer is easier than you might think New timers are easier to program than ever before with powerful features to help save you time and water while keeping your yard healthy and vibrant There are lots of models to meet your needs including indoor and out...

Страница 3: ...liminates controller output to the system valves without interrupting the clock operation F CIRCUIT BREAKER RESET BUTTON Circuit overload reset button F A built in circuit breaker protects the controller from damage due to current overload Push to reset after the source of trouble has been remedied G CURRENT STATION INDICATOR STATION indicator G identifies the current position of controller operat...

Страница 4: ...NTING 1 Choose a location that provides a minimum clearance of 13 wide x 10 high Since the electrical connections are provided at the bottom of the cabinet clearance should be allowed for the conduit connections etc Refer to Figure 2 2 Remove the 4 panel mounting screws carefully lift out the panel and disconnect the wire harness at the connectors 3 Position the cabinet on the wall at the mounting...

Страница 5: ...ection with a 1 2 conduit fitting 3 Connect a 120 Volt A C supply line to the LINE INPUT leads Main Power Wiring RC 7C RC 4C RC 1260C The 120 VAC step down transformer is mounted in the lower left hand comer of the controller cabinet A 1 2 14 NPSM conduit nipple extends through the cabinet bottom for connection to a conduit housing junction box or other approved attachment Make the electrical conn...

Страница 6: ...rve each circuit for proper operation Upon satisfactory checkout of the system proceed to adjust the controller clock CAUTION Dead Heading a pump running the pump s motor without water flowing through it may cause pump damage It may also result in personal injury from hot water spraying from the pump as a result of static water within the pump heating to a temperature where plastic pipe and fittin...

Страница 7: ... pin s corresponding to the day s on which watering is desired Re member each DAY pin represents a 24 hour period beginning at midnight 2 Next select the desired starting time s and push in the corresponding pin s on the HOUR dial Multiple starts within a given day may be scheduled after completion of the time accumulated by the previous cycle see NOTE following Step 3 3 The first mark square dot ...

Страница 8: ...ll operate for the time set on the dial after which the remaining stations will follow in sequence until the REST position again ap pears under the Station pointer RAIN SHUTDOWN There may be occasions where it is desired to interrupt all landscape irrigation Condi tions such as rainy weather system repair landscape renovation or other excavation work The temporary shutdown of the system is accompl...

Страница 9: ...Insufficient cycle time al lowed b Total cycle time coincides with a succeeding START pin a Adjust cycle time for more than 15 minutes b Reset the HOUR pins or readjust the accumulated cycle time Some stations do not op erate a Station time set at OFF b Faulty valve wiring a Set TIME control for more than 3 minutes b Check connections be tween controller and valves Also check valve actuators Stati...

Отзывы: