TO SET CLOCK DAY

EZ1-D

PROGRAMMING INSTRUCTIONS

Press

SET

CLOCK &

PROGRAM

.

Press

OR

until number corresponding to cur-
rent day appears in display

MON

1

TUE

2

WED

3

THU

4

FRI

5

SAT

6

SUN

7

Display will indicate:

Day

Wed

TO SET CLOCK HOUR AND MINUTE (MILITARY TIME)

Hour:
Press

.

Press

OR

until current hour appears in display

Display will indicate Hour:

Minute:
Press

.

Press

OR

until current minute appears in display

Display will indicate Minute:

Clock Time

Military Time

Clock Time

Military Time

12:00 Midnight (A.M.)

0000

12:00 Noon

1200

1:00 AM

0100

1:00 PM

1300

2:00

0200

2:00

1400

3:00

0300

3:00

1500

4:00

0400

4:00

1600

5:00

0500

5:00

1700

6:00

0600

6:00

1800

7:00

0700

7:00

1900

8:00

0800

8:00

2000

9:00

0900

9:00

2100

10:00

1000

10:00

2200

11:00

1100

11:00

2300

PGM 

A

/

C

SET

CLOCK &

PROGRAM

PGM 

A

/

C

SET

CLOCK &

PROGRAM

PGM 

A

/

C

SET

CLOCK &

PROGRAM

STATION

RUN

TIME

WHICH

DAYS TO

WATER

MANUAL

ON/STA.

ADVANCE

TIME OF

DAY TO
WATER

PGM 

A

/

C

SYSTEM

OFF

/

AUTO

Содержание EZ1-D

Страница 1: ...til current minute appears in display Display will indicate Minute Clock Time Military Time Clock Time Military Time 12 00 Midnight A M 0000 12 00 Noon 1200 1 00 AM 0100 1 00 PM 1300 2 00 0200 2 00 14...

Страница 2: ...RIABLE DAY CYCLE The EZ1 D Controller comes from the factory with a preset 7 day cycle This means the controller will operate as programmed for 7 days then repeat the cycle beginning with day 1 If you...

Страница 3: ...S TO WATER MANUAL ON STA ADVANCE TIME OF DAY TO WATER PGM A C SYSTEM OFF AUTO 1st Start Time for A Program Press TIME OF DAY TO WATER Press OR until the hour at which watering Display will indicate be...

Страница 4: ...wish for Station 1 to water PGM A C Will water for 10 minutes Repeat for remaining five stations To skip a station set that station s watering time to 0 Current station in A Program Display will indi...

Страница 5: ...eduled automatic start ADVANCING TO THE NEXT STATION OF A PROGRAM BEFORE PROGRAMMED WATERING IS COMPLETED SET CLOCK PROGRAM STATION RUN TIME WHICH DAYS TO WATER MANUAL ON STA ADVANCE TIME OF DAY TO WA...

Страница 6: ...act with each other or with the conduit See the wiring schematic provided on the body of the 50 HZ transformer and the figure below SYSTEM OFF AUTO SYSTEM OFF AUTO EZ1 CONTROLLER CABINET 3 TAP TRANSFO...

Страница 7: ...34 6289 FAX WARNING This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable...