25
25
Installation
ESP-Me Advanced User Manual
Connect Pump Start Relay
Connect an optional Pump Start Relay to the ESP-Me
controller.
Pumps are used in some places to draw water from a well
or other source. If you are activating a pump from the
controller, you must install a Pump Start Relay.
A Pump Start Relay connects to the controller in the same
way as a Master Valve, but connects differently at the water
source.
d
b
NOTE:
The ESP-Me controller DOES NOT provide
main power for a pump.
1.
Route the pump start relay wires through a knock-out
opening at the bottom or back of the unit.
d
d
CAUTION:
Do not route the pump start relay wires
through the same opening as the power wiring.
2.
Connect the Relay Input wire from the Pump Start Relay
to the master (MV) terminal on the base module.
3.
Connect the common wire from the Pump Start Relay to
the COMMON (COM) terminal on the base module.
1
2
3
4
VT = VALVE TEST
VT MV COM
2
4
V
A
C
G
N
D
S
E
N
S
VT MV COM
5
6
7
11
12
13
17
18
19
1
2
3
4
8
9
10
14
15
16
20
21
22
CONNECT
120 VAC
COMMON
RELAY
INPUT
PUMP START
RELAY
TO EXTERNAL
POWER SOURCE
2.
3.
1.
4.
Connect a short jumper wire from any unused station
terminal to a terminal in use.
1
2
3
4
VT = VALVE TEST
VT MV COM
2
4
V
A
C
G
N
D
S
E
N
S
VT MV COM
5
6
7
11
12
13
17
18
19
1
2
3
4
8
9
10
14
15
16
20
21
22
CONNECT
120 VAC
4.
d
d
CAUTION:
To avoid Dead Heading your pump do
one of the following for all unused stations (module
installed but not connected to a station wire):
d
l
Connect jumper wire across unused stations.
d
l
Set Station Run Time(s) to 0.
d
l
Set the station to Bypass the MV. (Refer to Set
Master Valve By Station in the Special Features
section.)
d
b
NOTE:
Default run times for program A is 10
minutes for stations 1-4.
d
b
NOTE:
The controller can support a maximum Coil
Inrush current of 11VA and a maximum Coil Hold
current of 5VA.
The following Rain Bird Pump Start Relays are available in
the USA only:
d
l
RBSR24WG1 - Universal Pump Start Relay
d
l
RBPL24WG1 - Pump Start Relay with Pressure Switch
For the most up to date compatibility list of pump start
relays, visit our website at:
www.rainbird.com/controllersupport
d
b
NOTE:
This controller is not compatible with the
Hunter
©
PSR22 and PSR52.