Installation
ESP-Me Advanced User Manual
Wiring Connections
Connect the valve wires for each station and for a
(optional) Master Valve, Pump Start Relay or Rain
Sensor.
Connect Valves
1.
Route the valve wires through a knock-out opening at
the bottom or back of the unit.
d
d
CAUTION:
Do not route the valve wires through the
same opening as the power wiring.
2.
Connect the power wire from each valve to the terminal
on the base module or Station Module that corresponds
to the desired station number (1-22).
3.
Connect the common wire from each valve to the
COMMON (COM) terminal on the base module.
4.
To perform a Valve Test- connect the common wire
to the “COM” terminal and the power wire to the “VT”
terminal. This will immediately turn the valve “ON” .
d
c
WARNING:
The “VT” terminal is always powered
“ON”.
1
2
3
4
VT = VALVE TEST
VT MV COM
2
4
V
A
C
G
N
D
S
E
N
S
VT MV COM
5
6
7
11
12
13
17
18
19
1
2
3
4
8
9
10
14
15
16
20
21
22
CONNECT
120 VAC
2.
1.
4.
3.
POWER
STATION 1
VALVE
STATION
2 VALVE,
ETC.
COMMON
Connect Master Valve
Connect an optional Master Valve to the ESP-Me
controller.
1.
Route the master valve wires through a knock-out
opening at the bottom or back of the unit.
d
d
CAUTION:
Do not route the master valve wires
through the same opening as the power wiring.
2.
Connect the power wire from the master valve to the
master (MV) terminal on the base module.
3.
Connect the common wire from the master valve to the
COMMON (COM) terminal on the base module.
1
2
3
4
VT = VALVE TEST
VT MV COM
2
4
V
A
C
G
N
D
S
E
N
S
VT MV COM
5
6
7
11
12
13
17
18
19
1
2
3
4
8
9
10
14
15
16
20
21
22
CONNECT
120 VAC
MASTER
VALVE
POWER
COMMON
1.
2.
3.