8
ESP-Me User Manual
Installation
Wiring Connections
Connect the valve wires for each station and for a
(optional) Master Valve, Pump Start Relay or Rain
Sensor.
Connect Valves
d
CAUTION:
Do not route the valve wires through the
same opening as the power wiring.
Connect Master Valve
Connect an optional Master Valve to the ESP-Me
controller.
d
CAUTION:
Do not route the master valve wires
through the same opening as the power wiring.
1.
To perform a Valve Test- connect the common wire
to the “COM” terminal and the power wire to the “VT”
terminal. This will immediately turn the valve “ON” .
c
WARNING:
The “VT” terminal is always powered
“ON”.
VT MV COM 5 6 7 11 12 13
17 18 19
1 2 3 4
8 9 10 14 15 16 20 21 22
VT MV COM
1 2 3 4
VT = VALVE TEST
CONNECT
120 VAC
POWER
COMMON
MASTER
VALVE
1.
VT MV COM 5 6 7 11 12 13
17 18 19
1 2 3 4
8 9 10 14 15 16 20 21 22
VT MV COM
1 2 3 4
VT = VALVE TEST
CONNECT
120 VAC
POWER
STATION
2 VALVE,
ETC.
STATION 1
VALVE
COMMON
2
4
VAC
G
ND
S
EN
S
2
4
VAC
G
ND
SEN
S