35
Contoller capacity :
1 Master Valve equipped with a Rain Bird TBOS latching solenoid for the system plus
1 Rain Bird TBOS latching solenoid per station. Make sure all wire from the controller to the
valves is code-approved for underground low voltage use.
Select the suitable wire size. All connections to the valve leads and any splice in the field must be
water tight. Use Rain Bird Quick Connect connectors : DBY, DBR or "King".
See wiring diagram.
GB
Master Valve:
The terminal marked "P" is used to
activate a Master Valve. It is STRONGLY
RECOMMENDED to use a Master Valve
to ensure proper operation of your
system in case, for example, the valve
wiring is accidentally cut, grit in the
piping flows into a valve, etc.
Important :
Maximum distance between the
controller and the valves using wire sized
1,5 mm
2
: 30 m
9V Anglais•00.qxd 20/11/02 15:01 Page 35