background image

300BPE

300BPES

Bonnet Assembly

1 Bleed screw with o-ring

204152

204152

2 Handle, flow control

231546

231546

NP Handle (sold separately)

240134

240134

3 Bolts (10 each)

231530

231530

4 Stem with o-ring, flow control

232063

232063

5 Solenoid seal

208629

208629

6 Bonnet with solenoid seal

231306

231306

7 Bonnet assembly

231548

231548

Solenoid Assembly

8 U-Frame

210914

210914

9 Rubber retainer

627167

627167

10 Coil

602118

602118

11 Base nut (plastic)

602606

602606

12 Tube, welded

630028

630028

300BPE

300BPES

13 Plunger/spring assembly

629453

629453

14 O-ring

202882

202882

15 Adapter assembly

231985

231985

16 Solenoid assembly (A)

B31800

B31800

B Solenoid wrench

B33003

B33003

Lower Assembly

17 Diaphragm spring

321545

321545

18 Diaphragm assembly

231543

19 Diaphragm assembly

231542

20 Scrapper

231544

21 Plug and o-ring (NPT)

231547

231547

Plug and o-ring (BSP)

231307

231307

O-ring kit (1, 12, 13, 16, 17, 19)

231513

231513

(A) This solenoid assembly supercedes all others.

Replacement Parts 

Refer to F2.

Troubleshooting (cont.)

a) If controller and solenoid power are

detected, there may be debris in the
solenoid assembly. Remove orange
rubber retainer by twisting and pulling
upward. Lift off the U-frame and sole-
noid. Use solenoid wrench (part num-
ber B33003) to counter-clockwise
remove the post assembly, being
careful as internal parts could fall out.

b)Remove plunger assembly and clean

debris on parts and solenoid bowl.
Replace plunger ensuring black 
surface faces outward. Clockwise
reinstall the post assembly, solenoid,
U-frame and rubber retainer.

c) Persistent problem may be an

obstruction lodged in main pipe.

d)If power is detected at the controller

and not the solenoid, inspect and
repair damaged lead wires.

Valve will not close

1. Ensure controller is not operating the

valve automatically. Ensure manual
internal bleed is off by clockwise
tightening the solenoid adapter.

F

Ensure manual external bleed is off
by clockwise tightening the bleed
screw.

E

2. Turn off water supply and swap 

solenoid

C

from an operational

valve; replace solenoid if necessary.

3. Turn off water supply and verify that

the solenoid adapter

F

o-ring is not

damaged; replace if necessary.
Check for debris in solenoid bowl
preventing plunger from creating a
positive seal.

4. Check overall system water-pressure

requirements and ensure that multiple
zone valves are not operating simul-
taneously.  Disallowing one zone
valve to close before another opens
can reduce the amount of backpres-
sure needed to close the diaphragm.

5. Turn off water supply and remove

bonnet

I

for possible debris or 

damage causing the diaphragm to
stick open.

Leakage

1. Disassemble parts and inspect o-

rings/sealing surfaces for damage.
Check replacement parts exploded
view for missing or replacement
parts.

Accessories or persistent 
problems

1. Refer to the appropriate installation

and operation manual for specific
troubleshooting procedures

2. Inside the US, please call the Rain

Bird Spec Hotline at (800) 458-3005.

3. Outside the US, please refer to the

back page for contact information.

4. Always visit us at www.rainbird.com.