300BPE
300BPES
Bonnet Assembly
1 Bleed screw with o-ring
204152
204152
2 Handle, flow control
231546
231546
NP Handle (sold separately)
240134
240134
3 Bolts (10 each)
231530
231530
4 Stem with o-ring, flow control
232063
232063
5 Solenoid seal
208629
208629
6 Bonnet with solenoid seal
231306
231306
7 Bonnet assembly
231548
231548
Solenoid Assembly
8 U-Frame
210914
210914
9 Rubber retainer
627167
627167
10 Coil
602118
602118
11 Base nut (plastic)
602606
602606
12 Tube, welded
630028
630028
300BPE
300BPES
13 Plunger/spring assembly
629453
629453
14 O-ring
202882
202882
15 Adapter assembly
231985
231985
16 Solenoid assembly (A)
B31800
B31800
B Solenoid wrench
B33003
B33003
Lower Assembly
17 Diaphragm spring
321545
321545
18 Diaphragm assembly
231543
–
19 Diaphragm assembly
–
231542
20 Scrapper
–
231544
21 Plug and o-ring (NPT)
231547
231547
Plug and o-ring (BSP)
231307
231307
O-ring kit (1, 12, 13, 16, 17, 19)
231513
231513
(A) This solenoid assembly supercedes all others.
Replacement Parts
Refer to F2.
Troubleshooting (cont.)
a) If controller and solenoid power are
detected, there may be debris in the
solenoid assembly. Remove orange
rubber retainer by twisting and pulling
upward. Lift off the U-frame and sole-
noid. Use solenoid wrench (part num-
ber B33003) to counter-clockwise
remove the post assembly, being
careful as internal parts could fall out.
b)Remove plunger assembly and clean
debris on parts and solenoid bowl.
Replace plunger ensuring black
surface faces outward. Clockwise
reinstall the post assembly, solenoid,
U-frame and rubber retainer.
c) Persistent problem may be an
obstruction lodged in main pipe.
d)If power is detected at the controller
and not the solenoid, inspect and
repair damaged lead wires.
Valve will not close
1. Ensure controller is not operating the
valve automatically. Ensure manual
internal bleed is off by clockwise
tightening the solenoid adapter.
●
F
Ensure manual external bleed is off
by clockwise tightening the bleed
screw.
●
E
2. Turn off water supply and swap
solenoid
●
C
from an operational
valve; replace solenoid if necessary.
3. Turn off water supply and verify that
the solenoid adapter
●
F
o-ring is not
damaged; replace if necessary.
Check for debris in solenoid bowl
preventing plunger from creating a
positive seal.
4. Check overall system water-pressure
requirements and ensure that multiple
zone valves are not operating simul-
taneously. Disallowing one zone
valve to close before another opens
can reduce the amount of backpres-
sure needed to close the diaphragm.
5. Turn off water supply and remove
bonnet
●
I
for possible debris or
damage causing the diaphragm to
stick open.
Leakage
1. Disassemble parts and inspect o-
rings/sealing surfaces for damage.
Check replacement parts exploded
view for missing or replacement
parts.
Accessories or persistent
problems
1. Refer to the appropriate installation
and operation manual for specific
troubleshooting procedures
2. Inside the US, please call the Rain
Bird Spec Hotline at (800) 458-3005.
3. Outside the US, please refer to the
back page for contact information.