![RAIMONDI SA 25 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/raimondi/sa-25/sa-25_use-and-maintenance-manual_3425612017.webp)
SA 25
SA 25
SA 25
SA 25
SA 25
Chapter 3
Handling, installation, adjustments
© Raimondi S.p.a.
Via dei Tipografi, 11 - 41100 Modena (Italia)
Tel.: +39.059.280.888 - Fax: +39.059.282.808
www.raimondiutensili.it - e-mail: [email protected]
Use and Maintenance Manual
Page 17/44-3
In case the machine needs to be stored during idle periods, it shall be kept in covered premises, so that the machine can be
protected from bad weather, and free from aggressive chemicals .
Before storing the machine, disconnection from the mains and unloading of the cooling water tank is recommended.
The machine shall be stored in environments with adequate temperatures (from -10 to + 70°C).
3.3 Power supply
The “SA 25” saw machine shall be supplied at the voltage corresponding to the value indicated on the “TECHNICAL DATA” label.
The machine shall be connected to a line only with an effective ground cable. In case of doubt, do not connect the machine.
Connect the machine to a 16A so
cket
.
THE USE OF EXCESSIVELY LONG PATCH CORDS OR POWER SUPPLY WITH CURRENT GENERATORS,
MIGHT LEAD TO THE FOLLOWING TROUBLES:
1.
SLOW STARTING OF THE MOTOR AND SAFETY DEVICES INTERVENTION;
2.
MOTOR OVERHEATING WITH POWER DROP;
3.
THE SWITCHING ON-OFF DEVICE
DOES NOT WORK
The “SA 25” machines shall be connected to the mains equipped with a residual current circuit breaker (RCCB) or a Class II
isolation transformer, having the characteristics indicated in the table:
Transformer
230V - 50 Hz 1,1 kW
115V - 60 Hz 1,1 kW
RCCB
9,5A Id 20mA
17A Id 20mA
FOR THE CORRECT USE OF THE RESIDUAL CURRENT CIRCUIT BREAKERS
,
DO NOT FORGET TO CHECK
THEIR EFFICIENCY BY MEANS OF THE TEST BUTTON PLACED ON THE FRONT PART OF THE DEVICE
ITSELF.
IF THE MACHINE IS CONNECTED TO THE MAINS BY MEANS OF A PATCH CORD
,
THIS SHALL HAVE THE
FOLLOWING CHARACTERISTICS:
1.
MAXIMUM LENGTH 10 METERS
2.
HAVING A SECTION SUITABLE FOR THE LOAD
3.
BEING COMPLETELY UNCOILED
CHECK THAT THE MOTOR AND TROLLEY UNIT ARE
CORRECTLY FASTENED.
Lifting
Two persons are required to lift the machine; to do so, grab the specific
handles positioned on the front and rear sides of the machine.
TWO PERSONS ARE REQUIRED TO CARRY OUT THE
TRANSPORT AND ASSEMBLY OPERATIONS