1.0  WARNINGS, CAUTIONS, AND NOTES 

Please read the entire instruction manual before using the voltage monitor. 

Also, read the warnings, cautions, and notes in Table 1. Failure to observe the warnings and 
cautions can lead to equipment damage or personal injury.  

If you have any questions concerning the manufacture, design, function, installation, operation 
or maintenance, contact Railway Equipment Company before proceeding.  

Table 1. Warnings, Cautions, and Notes 

Symbol 

Description 

 

WARNING indicates a potentially hazardous situation which, if not avoided, could result 
in death or serious injury. 

 

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in 
minor or moderate personal injury. It may also be used to alert against unsafe practices. 

NOTE 

NOTE indicates explanatory information that applies to the next step in the procedure. It 
is used to clarify and expand upon the importance of the procedural step when needed. 

 

If incorrectly wired, monitor can be damaged. Be sure to observe correct polarity on all 
DC wire connections, check the AC wiring instructions, and connect the ground wire.  

 

Содержание 520603-2V150

Страница 1: ...ree standing unit that features the ability to monitor two DC voltage sources and has optional temperature and current monitoring ability CRAGG RAILCHARGER Instruction Manual for Digital Voltage Monit...

Страница 2: ...ii Contents 1 0 WARNINGS CAUTIONS AND NOTES 1 2 0 OPERATION 2 2 1 Front Panel Features and Components 2 2 1 1 Figure 1 Front Panel of Voltage Monitor 3 2 1 2 Digital Display 3 2 1 3 Push Buttons 5 2...

Страница 3: ...fore proceeding Table 1 Warnings Cautions and Notes Symbol Description WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicate...

Страница 4: ...e fuse Channel two has a voltage range of 1 to 150 VDC but is only available for use if channel one is powered There is 2 500 volts isolation between channels The monitor has easy front panel access f...

Страница 5: ...y will change state and the channel one CHANNEL OK LED will go out Factory default is 50 0 VDC LOW VCH1 SET __ _ Low voltage setpoint for channel one adjustable from 0 to 50 0 VDC If the input voltage...

Страница 6: ...screen will display the software revision level installed on the monitor The addition of the temp probe adds the following screens HIGH TEMP SET ___ Temperature setting above which channel two relay w...

Страница 7: ...if enabled MODE This control is used to increment through the available screens 2 1 4 LED Status Indicators Two LEDs are used to indicate Channel OK one for each input channel 2 1 5 External Wiring C...

Страница 8: ...current level can be used to trigger a fault condition on channel two either independently or in conjunction with channel two voltage and or with the temperature sensor described in 2 1 7 2 1 7 TEMPE...

Страница 9: ...attery Voltage Monitor with Relay Outputs For Lead Acid and NiCad Batteries Programmable Voltage Parameters LED Status Indicators Digital Amperage Meter when optional Amp Probe is used Digital Voltage...

Страница 10: ...DC Channel 1 and 2 sensitivity is 100 MV per step The inputs are protected against reverse polarity The input power is protected by an internal resettable fuse The monitor outputs are form C relay wit...