background image

3

RailKing 4-6-2 K-4 Steam Engine

Set Up

There are a few simple steps you must take before operating this RailKing
steamer.  

• You should prime the operating smoke unit with smoke fluid before
operating.  Add 15-20 drops of smoke fluid through the smokestack, then
gently blow into the stack to eliminate any air bubbles in the fluid.  See Fig. 4.

• If you choose not to prime the unit with fluid, turn the smoke unit switch
located under the engine to the OFF position (Fig. 5).  Running the engine
without a primed smoke unit may cause damage.  See the “ProtoSmoke Unit
Operation” section of this book for more information on smoke unit
maintenance.

• You should lubricate all side rods and linkage components and pickup rollers
to prevent them from squeaking.  Lightly grease the outside idler and drive
gears (marked “G” in Fig. 3  on page 8) to prevent them from squeaking.  Use
light household oil and follow the lubrication points marked “L” in Fig. 2 on p. 
8.  Do not over-oil.  Use only a drop or two on each pivot point.

• Put your engine on the track and insert the reverse unit plug that extends out
of the tender into the receptacle at the back of the engine. WARNING: DO
NOT CONNECT THIS ENGINE TO A TENDER FROM ANOTHER
ENGINE; IT MAY CAUSE SERIOUS DAMAGE.

• Connect the draw bar between the engine and tender.  If there are two holes
in the draw bar, the hole located farthest from the tender is for the minimum
track operation, such as O-31 circles of track.  The second hole is for O-72 or
larger operation.

At this point, you are ready to begin running your engine.

Содержание RAILKING 4-6-2 K-4 STEAM ENGINE

Страница 1: ...lity chart on page 14 and is completely compatible with most other 3 rail locomotives rolling stock and accessories M T H takes pride in manufacturing high quality products like your RailKing steam en...

Страница 2: ...Proto Dispatch 6 Volume Control 7 Maintenance 8 Lubrication and Greasing Instructions 8 Cleaning the Wheels Tires and Track 9 Locomotive Traction Tire Replacement 9 Smoke Unit Maintenance 10 Locomoti...

Страница 3: ...s and linkage components and pickup rollers to prevent them from squeaking Lightly grease the outside idler and drive gears marked G in Fig 3 on page 8 to prevent them from squeaking Use light househo...

Страница 4: ...ontinue to ring from the time your turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neutral To put the engine into forward and then...

Страница 5: ...istle 2 bells code to return it to the other state You will want to do this during the initial neutral upon start up if you ever couple this engine to another engine that is not equipped with speed co...

Страница 6: ...ape player to connect your microphone to the remote lock on To use Proto Dispatch simply plug the mini cable into the microphone and into the Mic port on the left side of the remote lock on and speak...

Страница 7: ...ounds made by this engine turn the master volume control knob located under the engine clockwise to increase the volume and counter clockwise to decrease the volume see Fig 1 Proto Sound 2 0 Volume Ad...

Страница 8: ...s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first To access the gear box do the following Unscrew...

Страница 9: ...and denatured alcohol not rubbing alcohol Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on the rails Traction Tire Replacem...

Страница 10: ...enjoy trouble free smoke unit operation for years When preparing to run this engine add 15 20 drops of smoke fluid through the smokestack see Fig 4 We recommend M T H ProtoSmoke Seuthe LGB or LVTS fl...

Страница 11: ...plate away and inspect the wick If it is darkly discolored and hard it should be replaced You can obtain replacement parts directly from the M T H Parts Department Locomotive Light Bulb Replacement T...

Страница 12: ...when I press the bell button You may be pressing the button too quickly Try pressing the whistle button more slowly taking approximately one full second to fully depress the button You may be pressing...

Страница 13: ...tubular track It is also compatible with virtually any standard AC transformer See page 14 for a complete list of compatible transformers and wiring instructions Volume Remedy The sounds seem distort...

Страница 14: ...t Standard Lionel1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electronic Lionel LW A U 8 18v 75 Watt Stan...

Страница 15: ...en using electrical products basic safety precautions should be followed including the following Read this manual thoroughly before using this device M T H recommends that all users and persons superv...

Страница 16: ...e address daytime phone number a copy of your sales receipt the Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the descript...

Отзывы: