background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Crossing Gate Contents:

 

Crossing Signal Contents: 

WigWag Signal Contents:

 

Master

  (1) DZ-1010 Crossing Gate w/sound  (1) DZ-1020 Crossing Signal w/sound  (1) DZ-1030 WigWag Signal w/sound 

Slave

 

(1) DZ-1012 Crossing Gate no sound  (1) DZ-1022 Crossing Signal no sound  (1) DZ-1032 WigWag Signal no sound 

ALL include: 

(2) DZ-1011 Block Signal Detectors 
Mounting screws for gates or signals & detectors and (5) Twist-on connectors

 

 

The Z-Stuff for Trains crossing gates, crossing 
signals and wigwags are unique, scale size 
crossing devices that include optical, infrared 
detection of passing trains to operate them. A 
digitally recorded crossing bell sound is also 
included. They do not require any connection to 
the track; however, they can be used with 
simple isolated rail control if desired. Each unit’s 
control electronics has one HOLD input and two 
TRIGGER inputs. As long as the HOLD input is 
connected to COMMON the gates will stay 
down or continue to operate. Connecting a 
TRIGGER input to connect causes the signals 
to operate but they will stop after about 6 
seconds unless a train enters the crossing. Up to (4) tracks may be 
accommodated at a crossing, although additional block signal detectors would 
be required. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DZ-1010/1020/1030 Set 

Crossing Gates / Signals / WigWags

 

With (2) DZ-1011 Block Signal Detectors

 

Rev 8-8-03

Содержание DZ-1010

Страница 1: ...ction of passing trains to operate them A digitally recorded crossing bell sound is also included They do not require any connection to the track however they can be used with simple isolated rail control if desired Each unit s control electronics has one HOLD input and two TRIGGER inputs As long as the HOLD input is connected to COMMON the gates will stay down or continue to operate Connecting a ...

Страница 2: ...nal does not receive any reflected light from its IR LED The GREEN LED should be lighted at this time 7 Place your hand about 1 inch from the SENSOR on the side of the Block Signal The GREEN LED should go out and the RED LED should light This should also actuate the crossing gates signals 8 Check to make sure that when one Block Signal changes from GREEN to RED that the other Block Signal also cha...

Страница 3: ...LED s to flash The YELLOW and WHITE wires will only TRIGGER the operation and the LED s to flash but after 6 8 seconds the operation will stop even if the wires remain connected to COMMON This is so trains which are detected but do not enter the crossing will not cause the continuous operation of the signals The two units can be separated by about 14 inches DZ 1011 Installation The DZ 1011 Block S...

Страница 4: ...block signals is wired to one of the TRIGGER inputs The block signals on TRACK 1 are wired to the WHITE TRIGGER input and the block signals on TRACK 2 are wired to the YELLOW TRIGGER input ISOLATED RAIL usage The crossing signals may be used with isolated COMMON rails to control the units Be sure to connect the COMMON of the power of the crossing signals to the TRACK COMMON The isolated rail is co...

Отзывы: