RemovethefourPhillipsscrewsfromthechassisthenliftthebodyawayfromthechassis.
STEP
smallpipetteofProtoSmokefluidisincluded). Do
notoverfilltheunitorthefluidmayleakoutandcoat
theinteriorenginecomponents.
Ifyouchoosenottoaddthefluid(orhavealready
addedthefluidbutchoosetorunsmoke-free),turnoff
thesmokeunitswitchlocatedundertheenginebody.
Whenthesmokeoutputwhilerunningtheengine
beginstodiminish,addanother10-15dropsofsmoke
fluidorturnthesmokeunitoff.
Whenstoringtheunitforlongperiodsoftime,
youmaywanttoaddabout15dropsoffluidto
preventthewickfromdryingout.
Afterremovingtheenginefromstorage,add
another25dropsoffluid,lettingthewicksoak
upthefluidfor15minutespriortooperation.
Ifyouexperiencepoorornosmokeoutputwhenthesmoke
unitisonandhasfluid,checkthewicktoseeifithas
becomehard,blackened,andunabsorbentaroundthe
heatingelement. Removetheboilerasshownbelow.
Removethesmokeunitinspectioncoverfromthe
locomotive'sbody(seeright). Afterremovingthechassis
andinspectioncoverscrews,lifttheinspectionplateaway
andinspectthewick. Ifitisdarklydiscoloredandhard,it
shouldbereplaced. Whenprimingnewwickadd40drops.
!
!
!
Failureeithertoaddfluidtotheunitortoturnit
offmaydamagethesmokeunitheatingelement
and/orwickingmaterial.
LocomotiveLightBulbReplacement
!
Toreplacethelightbulbinthelocomotive,followtheboilerremovalinstructionsbelow.
Wickin
Poor
Condition
Wickin
Good
Condition
SmokeUnitCover
13
Runningtheenginewithoutaprimed
smokeunitmaycausedamage
Add15-20Drops
SmokeFluid
Add15-20Drops
SmokeFluid
SmokeUnit
ON/OFFSwitch