13
RD-WP36 has a compact design, high load
and low power consumption. Easy to clean
filter.
Before operating the pump, please note the
following!
• The pump can be plugged into any izpliran
and grounded contact (based on safety).
The contact must be powered 230V-50Hz,
and fuse minimum 6A.
Attention! In case the pump is used in prox
-
imity to a swimming pool or garden reser
-
voirs need to be connected to a grounding
system with a current of mah.30mA. Do
not switch the pump if there are people in
the pool or tank! Connectivity described
grounding system, contact a qualified
electrician.
Attention! (Important for your own safety)
Before turning their submersible pump,
please note the following things should be
checked by an expert.
• Grounding
• Clearance
• The emergency switch chain must meet
the electrical installation and works flaw
-
lessly.
• All electrical connections must be protect
-
ed from moisture
• If you power cord can be touched by
outsiders, be sure it is appropriate for them
unattainable height.
• The proximity and circulation of fluids ag
-
gressive and abrasive material around the
pump and power cord should be avoided at
all costs.
• In winter conditions take precautions
against possible freezing of the submersible
pump.
• It is necessary to protect the pump from
direct impact of rain.
Take the necessary measures to prevent
child access to the pump or power cord.
It is the pump to be suspended for the
intended purpose handle of the pump body.
To make sure that the pump will operate
flawlessly necessary intake openings in the
lower part of the body are far from any dirt
or mud bottom vegetation.
If the water level is falling too rapidly, it will
lead to drying out of accumulated sedi
-
ment or sludge in the bottom of the shaft,
or around and in the pump inlet, which can
lead to malfunction of the pump. Periodi
-
cally clean the pump from debris and test
whether it involves a timely manner.
supply
Your new submersible pump is equipped
with a protection from electric shock plug,
designed for connection to the supply volt
-
age 220V-50Hz. Rest assured that contact
you plug the pump is secured and is in
working condition.
Attention! If the cord or plug traces of any
injuries caused by external interference do
not use the pump before them repaired.
Important! The amendment necessarily
need to be carried out by a qualified electri
-
cian.
Содержание GARDEN TOOLS RD-WP36
Страница 43: ...43 ...
Страница 69: ...RD WP36 ...
Страница 84: ......
Страница 88: ......
Страница 89: ......