Now you are ready to use your water dispenser. 

 

ATTENTION: 

If  you  do  not  plan  to  use  the  water  heating  function  for  more  than  two  or  three  days,  we 
recommend that you turn off the hot water function. 

 



WARNING



IMPROPER USE OF THE GROUNDED PLUG CAN RESULT IN THE RISK OF ELECTRICAL 
SHOCK. IF THE POWER CORD IS DAMAGED, HAVE IT REPLACED BY AN AUTHORIZED 
PRODUCTS SERVICE CENTER. 

 

OPERATING YOUR WATER DISPENSER 

Electrical Connection 

This  appliance  should  be  properly  grounded  for  your  safety.  The  power  cord  of  this  appliance  is 
equipped  with  a  three-prong  plug  which  mates  with  standard  three  prong  wall  outlets  to  minimize 
the possibility of electrical shock. 
 
Plug the appliance into an exclusive properly installed-grounded wall outlet. Do not, under any 
circumstances  cut  or  remove  the  third  (ground)  prong  from  the  power  cord.  Any  questions 
concerning  power  and/or  grounding  should  be  directed  toward  a  certified  electrician  or  an 
authorized Product Service Center. 
 
This appliance requires a standard 120 Volts A.C. / 60Hz electrical outlet with three-prong ground. 
 
The  cord  should  be  secured  behind  the  appliance  and  not  left  exposed  or  dangling  to  prevent 
accidental injury. 
 
Do not use an adapter plug with this appliance. 
 
Do not use an extension cord with this appliance. If the power cord is too short, have a qualified 
electrician or service technician install an outlet near the appliance. 
 

Steps To Replace Water Bottle 

  Use a clean cloth to wipe off neck of bottle. 
  Remove cap, if there is one on. 
  Insert the water bottle on the water intake over reservoir opening so it settles properly on it. 
  Wipe off any water, which may have splashed on dispenser top. 

 

 

 

  

              Note: The hot water faucet has a child safety guard attachment 

Содержание RWC-120

Страница 1: ...ic Hot and Cold Water Cooler INSTRUCTION MANUAL MODEL NUMBER RWC 120 120V 60HZ 75W Cooling 120V 60HZ 550W Heating For customer service in USA and Canada please call 1 866 499 6389 WWW RAGALTAUSA COM SAVE THIS INSTRUCTION MANUAL ...

Страница 2: ...erecho de cambiar los materiales y especificaciones sin previo aviso PARTS AND FEATURES 1 WATER INTAKE 7 HEATING POWER SWITCH 2 COOLING INDICATOR 8 COOLING POWER SWITCH 3 HEATING INDICATOR 9 BODY 4 COLD WATER FAUCET BLUE 10 POWER CORD 5 HOT WATER FAUCET RED 11 WATER DRAIN CAP 6 REMOVABLE DRIP TRAY Important Safety Instructions WARNING To reduce the risk of fire electrical shock or injury when usin...

Страница 3: ...enser is not recommended for outdoor use Do not locate the dispenser in area where the temperature may fall below freezing 32º F Keep area around dispenser free of dust and dirt Keep the reserve supply of water bottles away from excessive heat and light Never unplug the water cooler except for maintenance Before Using Your Water Dispenser Before connecting the appliance to the power source let it ...

Страница 4: ...umstances cut or remove the third ground prong from the power cord Any questions concerning power and or grounding should be directed toward a certified electrician or an authorized Product Service Center This appliance requires a standard 120 Volts A C 60Hz electrical outlet with three prong ground The cord should be secured behind the appliance and not left exposed or dangling to prevent acciden...

Страница 5: ...efore calling the service center TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Water dispenser does not operate Not plugged in The circuit breaker tripped or a blown fuse Water cooler is not cold enough Check to be sure the cold switch on the back is ON Water dispenser hot water is not hot enough Check to be sure the hot switch on the back is ON Vibrations Check to assure that the water dispenser i...

Страница 6: ...FUSE 7 COOLER 8 COOLING INDICATOR 9 95º C THERMOSTAT TECHNICAL PARAMETERS Model RWC120 Power Source 120V 60Hz Rated input Power Cooling Heating 75W 550 W Water Cold Water Hot Water 8 C 15 C 85 C 95 C Cooling Capacity 2 L h Heating Capacity 5 L h Net Weight Kg 6 Protection against electric shock TYPE I ...

Страница 7: ...tomer Service Number 1 866 499 6389 www ragaltausa com 5870 NW 163th Street Miami Lakes Florida 33014 USA 1 Year limited warranty Covers all defective materials and workmanship under normal household use MADE IN CHINA ...

Страница 8: ... de Agua Fría y Caliente MANUAL DE INSTRUCCIONES NUMERO DE MODELO RWC 120 120V 60HZ 75W Frío 120V 60HZ 550W Caliente Para servicio al cliente en USA y Canadá llame al 1 866 499 6389 WWW RAGALTAUSA COM LEA ESTAS INSTRUCCIONES COMPLETAMENTE ...

Страница 9: ...UA FRIA AZUL 10 CABLE DE ENERGIA 5 GRIFO DE AGUA CALIENTE ROJO 11 TAPON DE DRENAJE DE AGUA 6 BANDEJA DE RECOLECCION DE AGUA REMOVIBLE Instrucciones importantes de seguridad ADVERTENCIA Para reducir el riesgo de incendio choque eléctrico o lesiones al utilizar su aparato siga estas instrucciones básicas Lea todas las instrucciones antes de utilizar el dispensador de agua Nunca limpie las partes con...

Страница 10: ... 32 º F Mantenga el alrededor del dispensador libre de polvo y suciedad Mantenga el suministro de reserva de botellas de agua lejos del calor excesivo y de la luz No desconecte el refrigerador de agua excepto para el mantenimiento Antes de usar el Dispensador de Agua Antes de conectar el aparato a la fuente de energía se deja reposar en posición vertical por aproximadamente 2 horas Esto reducirá l...

Страница 11: ...r pregunta relativa a la fuente de alimentación y o la toma de tierra debe ser atendida por un electricista certificado o un Centro Autorizado de Servicio de productos Este dispositivo requiere una toma de corriente eléctrica estándar de 120 voltios AC 60Hz con tres puntas a tierra El cable debe estar amarrado detrás del aparato y no debe estar expuesto o colgando para prevenir accidentes y lesion...

Страница 12: ...AS PROBLEMA POSIBLE CAUSA Dispensador de agua no funciona No está enchufado El circuito eléctrico está roto o tiene un fusible quemado El enfriador de agua no enfría lo suficiente Asegúrese de que el interruptor de frío en la parte de atrás este encendido El calentador de agua no calienta lo suficiente Asegúrese de que el interruptor de caliente en la parte de atrás este encendido Vibraciones Aseg...

Страница 13: ... FUSIBLE 7 ENFRIADOR 8 INDICADOR DE ENFRIAMIENTO 9 TERMOSTAT0 DE 95º C PARÁMETROS TÉCNICOS Modelo RWC120 Fuente de Energía 120V 60Hz Nivel de Potencia Enfriando Calentando 75W 550 W Agua Agua Fría Agua Caliente 8 C 15 C 85 C 95 C Capacidad de Enfriamiento 2 L h Capacidad de Calentamiento 5 L h Peso Neto Kg 6 Protección contra descarga eléctrica TIPO I ...

Страница 14: ...idos y Canadá llame al 1 866 499 6389 WWW RAGALTAUSA COM 5870 NW 163th Street Miami Lakes Florida 33014 USA 1 Año de Garantía Limitada Cubre cualquier defecto en el material utilizado y mano de obra bajo uso doméstico normal FABRICADO EN CHINA ...

Отзывы: