OUTMax
These values are for the Output MAX These values need to relate to the real quantity measured or the PID being
sent.
As per the above ranges. Max values
%X1,%YVal1; %X2,%YVal2
These parameters control the linearity of the scale between minimum and maximum. They map the input reading %
to an output reading % that is displayed on the meter scale.
The start point is always 0%,0% and the final point is always 100%,100%. In between are 2 movable points that
control the curve used. The chart below shows a few examples. The % values use the defined In_Min and In_Max to
set the 0% to 100% range.
Examples:
%x1 %y1
%x2
%y2
slow start
10
5
75
75
gradual curve
10
15
65
85
s-shaped
30
20
70
80
sub-range
25
0
75
100
linear straight
25
25
75
75