background image

User Interfaces  

SFC6400A/SFC1450A Synthesized Frequency Upconverter 

4-6 

 

TM106 – Rev. 1.1

 

4.2.3  Switch Menu Options and Parameters 

 
This Menu is only available when the Upconverter is connected in a 1:1 or 1:N Switch configuration 
as the Backup Unit. 
 

BACKUP MODE: 

{MANUAL, AUTO-NONREVE, AUTO-REVERTI} 

 

 

Sets the Backup Mode of the Switch. 

 
 

 

Manual:

  A Prime Converter can be backed up through 

manual control only. 

 
 

 

Auto-Nonrevertive:

  A Prime Converter will be backed up 

if it fails.  It will remain backed up until it is manually 
unbacked. 

 
 

 

Auto-Revertive:

  A Prime Converter will be backed up if it 

fails.  If a second Converter, which has been deemed 
higher priority (see Monitor Backup State below) fails, the 
Switch will unback the first and backup the second 
Converter.  Also, if the first Converter recovers after it has 
been backed up (i.e., no longer has a fault), the Switch 
will unback it and place it online again. 

 

FORCE BACKUP <SELECT PRIME>: 

{PRIME 1 - 8, UNBACK} 

 

When in Manual Backup Mode, this selection will force 
the selected Prime to be backed up.  Unback will release 
any Prime that is currently backed up. 

 
LEARN <SELECT PRIME>: 

{PRIME 1 - 8, ALL} 

Causes the Backup Unit to "Learn" all the settings of the 
selected Primes.  The Backup Upconverter can only 
backup a Prime that it has learned.  A backup test is 
performed as the unit is learned. 

 

FAULT DELAY: 

{00050 - 10000} 

 

Sets the delay between the time a Fault occurs in a 
Prime Unit and the time it is acknowledged by the 
Backup.  The unit is Milliseconds (ms). 

 
COMPENSATION: 

{ENABLE, DISABLE} 

 

Enables or disables the Compensation control described 
in Prime Setup below. 

 

Содержание SFC1450A

Страница 1: ...C6400A SFC1450A Synthesized Frequency Upconverter Installation and Operation Manual TM106 Revision 1 1 Radyne ComStream Corp 3138 E Elwood St Phoenix AZ 85034 602 437 9620 Fax 602 437 4811 www radn co...

Страница 2: ......

Страница 3: ...ranty period Warranty Coverage Limitations The following are expressly not covered under warranty 1 Any loss damage and or malfunction relating in any way to shipping storage accident abuse alteration...

Страница 4: ...It is at this time that Radyne ComStream Corporation will authorize the product or part to be returned to the Radyne ComStream Corporation facility or if field repair will be accomplished The Repair...

Страница 5: ...Key will be represented as 7 ENTER Cautions and Warnings A caution icon indicates a hazardous situation that if not avoided may result in minor or moderate injury Caution may also be used to indicate...

Страница 6: ...of any circuitry other than the circuitry employed in Radyne ComStream Corporation systems and equipment Furthermore since Radyne ComStream Corporation is constantly improving its products reserves th...

Страница 7: ...______________ 3 2 3 1 2 1 1 Switch ______________________________________________________ 3 2 3 1 3 1 8 Switch ______________________________________________________ 3 2 3 2 Optional Chain Switching...

Страница 8: ...7 RLLP Summary_______________________________________________ 4 30 4 5 Terminal Port User Interface ________________________________________ 4 31 4 5 1 Terminal Main Menu ____________________________...

Страница 9: ...2 Access View _____________________________________ 4 43 4 6 2 20 Key Generation Mode__________________________________________ 4 43 4 6 2 21 Context Engine ID _______________________________________...

Страница 10: ..._______________________________________________ 5 9 Section 6 Maintenance and Troubleshooting 6 0 Periodic Maintenance_______________________________________________ 6 1 6 1 Failure Analysis _________...

Страница 11: ...________________________________ A 17 A 14 Auto Mode Command P1 1 B1 1 B1 8 ____________________________ A 17 A 15 Manual Mode Command P1 1 B1 1 _______________________________ A 17 A 16 Manual Backup...

Страница 12: ...___________________________B 1 B 2 Converter Queries _________________________________________________B 2 B 3 Switch Queries ___________________________________________________B 6 B 4 Converter Comman...

Страница 13: ...e available at the front panel Operating parameters such as frequency channel gain gain offset and switch settings backup only can be readily set and changed at the front panel Additionally all functi...

Страница 14: ...Introduction SFC6400A SFC1450A Synthesized Frequency Upconverter 1 2 TM106 Rev 1 1...

Страница 15: ...hannel settings of the primary converters The backup converter can be operated automatically in which case an automatic backup of a faulted online Converter occurs after a user programmed delay The Ba...

Страница 16: ...a table or suitable stable surface if required Before initially applying power to the unit it is a good idea to disconnect the transmit output from the operating station equipment This is especially...

Страница 17: ...ype for the installation either the cable or the power connector end should be replaced The power supply itself is designed for universal AC application See specifications for the appropriate voltages...

Страница 18: ...designed to minimize the amount of hardware in the system while maximizing performance Spurious performance in the Upconverter is critical and in particular LO related spurious In Band is nonexistent...

Страница 19: ...rred to as the Prime If the Converter is connected as the Backup then all the Switch controls are available to the user on that unit Figure 3 2 illustrates a typical interconnection of a SFC Upconvert...

Страница 20: ...ows the address position in the rack and the fault status of all of the converters in the rack In the event of multiple failures the highest priority converter that fails is backed up first The chain...

Страница 21: ...Synthesized Frequency Upconverter 3 4 TM106 Rev 1 1 Refer to Figure 3 4 for Chain Switching Operation in a 1 1 configuration and Figure 3 5 for a 1 N configuration Figure 3 3 RCU108 Typical Interconne...

Страница 22: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Operation TM106 Rev 1 1 3 5 Figure 3 4 Chain Switching Operation in a 1 1 Configuration...

Страница 23: ...Operation SFC6400A SFC1450A Synthesized Frequency Upconverter 3 6 TM106 Rev 1 1 Figure 3 5 Chain Switching Operation in a 1 N Configuration...

Страница 24: ...on and labeling of the front panel The front panel is divided into four functional areas Monitoring Ports LCD Display Cursor Control Arrows Numeric Keypad and LED Indicators Each is described below Ta...

Страница 25: ...own Arrow Keys The Down Arrow Key is used to move from a Menu screen to the selections or submenus beneath that Menu The Up Arrow does the reverse moving from a submenu or selection to a higher level...

Страница 26: ...verter is in Remote Mode In this mode the unit settings can only be modified and controlled via a remote interface ONLINE Green When illuminated indicates that the backup converter has been placed onl...

Страница 27: ...in the Backup Mode EXT REF Yellow This LED illuminates when an external 10 MHz reference signal has been applied to the converter A LO fault may occur when the external reference is applied or remove...

Страница 28: ...725 7 025 GHz C Band India 14 0 14 5 GHz Ku Band Normal 13 75 14 50 GHz Ku Band Extended Sets the RF output frequency The available range depends upon the Converter model CHNL GAIN dB 20 0 to 30 0 dep...

Страница 29: ...Switch will unback the first and backup the second Converter Also if the first Converter recovers after it has been backed up i e no longer has a fault the Switch will unback it and place it online ag...

Страница 30: ...of the Backup Unit to account for variations in loss through the system This allows the user to ensure that the signal path of a particular Prime Converter maintains the same output power when backed...

Страница 31: ...eting the Reference input specification is connected to J4 the unit will switch to the Internal The process is completely automatic and it is independent of M C control MON VOLTAGES RF DETECTOR V Moni...

Страница 32: ...50A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 9 TEST REF OFFSET Menu and cannot be changed from this Menu REFDAC VOLTAGE Displays the expected voltage output of the VCO Referen...

Страница 33: ...odule indicates an unlocked condition SIGNAL FAULT PASS FAIL UNMASKED MASKED Reports a failure when there is an IF Detect Fault BACKUP FAULT PASS FAIL UNMASKED MASKED backup converter only Indicates t...

Страница 34: ...NMASKED MASKED Indicates a fault if the Controller PCB Microprocessor reads back an unexpected value from the CPLD This is a check performed on system power up FPGA FAULT PASS FAIL UNMASKED MASKED Ind...

Страница 35: ...ed CLEAR ALARMS ENT Y CLR N Pressing ENTER will clear all of the Latched Alarms currently stored 4 2 6 System Menu Options and Parameters CONTROL MODE FT PANEL TERMINAL COMPUTER ETHERNET Sets the Cont...

Страница 36: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 13 ECHO MODE OFF ON Allows the user to control whether the input at the terminal is echoed back...

Страница 37: ...Y YY Displays the revision number of the installed M C Firmware where XXXX is the firmware number and Y YY is the version FW XXXX 19DEC2002 Displays the revision number and release date of the install...

Страница 38: ...Card Stand Alone CONVERTER TYPE DN CONVERTER UPCONVERTER Indicates whether the unit is an Upconverter or a Upconverter This display will match the text on the Front Panel Overlay CONVERTER BAND C BAN...

Страница 39: ...Converter with a set of default parameters Refer to Section 4 5 for actual default settings SNMP DEFAULT Password protected Configures the Converter SNMP Ethernet Interface settings to default values...

Страница 40: ...0 MHz The RF Monitor output can be measured with a frequency counter of known calibration The stability of the 10 MHz Reference is related to the temperature of a 10 MHz crystal inside the unit A prop...

Страница 41: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 18 TM106 Rev 1 1...

Страница 42: ...ng This aging reset in not well understood but the manufacturers of crystals believe it to be related to a gradual relaxation of the molecular makeup of the quartz substrates and the conductive films...

Страница 43: ...raps around and ends up at the CONVERTER screen again 4 Press and release the Down Arrow Key The FREQUENCY GHz Screen is displayed 5 Press and release ENTER once The cursor appears at the lower left c...

Страница 44: ...until the cursor is at the digit to the right of the decimal point Press the Up Arrow Key until the display shows 06 000000 The cursor is still visible and flashing over the number 0 to the right of t...

Страница 45: ...een the converter connector J8 and the remote controller See Section 5 9 for detailed pinout information The port is factory set to communicate as the DCE Data Communications Equipment with the follow...

Страница 46: ...Protocol The Radyne ComStream Link Level Protocol RLLP is an alternative serial protocol used in conjunction with the remote port 4 4 2 1 RLLP Protocol Structure When new features are added to Radyne...

Страница 47: ...rrounding overhead may be shown as follows S1 S2 B0 B1 B2 B3 B4 B5 B6 B7 S1 S2 etc The stop bits S1 and S2 are each a mark Data flow remains in a hold mode until S2 is replaced by a space If S2 is fol...

Страница 48: ...001001b 00100101b OPCODE Byte 1 00h 00000000b 00101000b OPCODE Byte 2 03h 00000011b 00101000b DATA Byte 1 DFh 11011111b 00000111b DATA Byte 2 FEh 11111110b 00000101b Thus the checksum is 00000101b whi...

Страница 49: ...Number FSN is included in every message packet and increments sequentially When the M C computer or bus linked equipment initiates a message it assigns the FSN as a tag for error control and handshak...

Страница 50: ...dshake acknowledgment involves a reversal of source and destination ID codes in the next message frame followed by a response code in the OPCODE field of the message packet from the equipment under co...

Страница 51: ...ed in a direct linked single thread configuration accessible to the M C computer directly For example if two Converters with different addresses DESTINATION IDs are linked to the same control bus at t...

Страница 52: ...4500 5000 a DMD15 modem or a DVB3030 Radyne ComStream Corporation recommends that the multi drop override IDs be issued only during system configuration as a bus test tool by experienced programmers a...

Страница 53: ...is added unless the user needs access to that feature 4 4 2 7 RLLP Summary The RLLP is a simple send and wait protocol that automatically re transmits a packet when an error is detected or when an ac...

Страница 54: ...changed at the front panel by using the System Terminal Menu The Terminal Control Mode is Menu driven and the allowable values for each item number will be shown To change an item type in its number f...

Страница 55: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 32 TM106 Rev 1 1 4 5 2 Terminal Converter Controls Menu 4 5 3 Terminal Switch Controls Menu...

Страница 56: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 33 4 5 4 Terminal Alarm Status Masks Menu 4 5 5 Terminal Monitor Status Menu...

Страница 57: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 34 TM106 Rev 1 1 4 5 6 Terminal Test Controls Menu 4 5 7 SNMP Controls Menu...

Страница 58: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 35 4 5 8 Terminal Event Buffer Menu...

Страница 59: ...eT or 100BaseT Ethernet connection 4 6 1 Ethernet Port Configuration 4 6 1 1 Connecting the Terminal 1 Connect a computer serial port or dumb terminal port to the SFC Upconverter Terminal Connector J6...

Страница 60: ...available and requesting input If the input is multiple choices the user is prompted to use the Spacebar to scroll to the desired selection and then press ENTER An input can be aborted at any time by...

Страница 61: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 38 TM106 Rev 1 1...

Страница 62: ...r case sensitive 4 Select OK 4 6 2 5 Changing the Logon Password To change the password logged on so that the SNMP Security selection appears Press 54 followed by ENTER to open the Change Logon Passwo...

Страница 63: ...ging Your Privacy Password To change your privacy password select 56 followed by ENTER to open the Change Password dialog Change Password 1 Old Password 2 New Password 3 Re enter New Password 4 OK 5 C...

Страница 64: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 41...

Страница 65: ...er words the transport layer needs to be able to open a connection to the entity specified by the server IP Address field 1 Select 41 ServerIPAddr Enter the Server Internet Address in dot notation and...

Страница 66: ...sing Terminal Command Number 30 The messages are sent to specific pre defined hosts The Primary and Secondary Trap Hosts IP Addresses are setup using Terminal Commands 31 and 32 Each host should be ac...

Страница 67: ...User Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 4 44 TM106 Rev 1 1...

Страница 68: ...ts of variables based on the identity of the manager and the security level used in the request A view is a group of MIB variables on the agent The agent defines a view for each user based on the user...

Страница 69: ...e ICMP protocol to report if a host is responding To check whether the SFC Upconverter is reachable use the PING program installed on your computer along with the modem IP Address set in Section 3 2 3...

Страница 70: ...Management Information Base MIB which uses a hierarchical naming scheme In this scheme an Object Identifier OID identifies each object The OID is a sequence of non negative integers that uniquely des...

Страница 71: ...ath which each vendor may define its own structure Vendors are assigned Private Enterprise Numbers PENs that uniquely identify them They may then place all objects specific to their devices in this tr...

Страница 72: ...SFC6400A SFC1450A Synthesized Frequency Upconverter User Interfaces TM106 Rev 1 1 4 49 Figure 4 4 Object Identifiers in the Management Information Base Sheet 2 of 2 Refer to Appendix C for MIB listing...

Страница 73: ...wer consumption is 50 W The switch turns power on and off to the unit A chassis ground connection can be made at the 10 size stud located between the IF J2 and Ethernet J9 connectors The Power Cord co...

Страница 74: ...ial I O Port J8 is a D Sub 9 Pin Female Connector This port provides a serial interface that can be configured as either an RS 232 or RS 485 interface and allows the user to remotely control all of th...

Страница 75: ...puts are within 50 90 MHz for standard units and 100 180 MHz for units equipped with 140 MHz 5 7 Terminal J6 The Terminal Port allows for complete control and monitoring of all Upconverter parameters...

Страница 76: ...485 protocol the master will poll a specific slave by address and only then will the slave unit respond The swapping of Transmit Data and Receive Data is accomplished in the inter converter cables as...

Страница 77: ...emale Connector that connects each converter with the RCU101 or RCU108 Backup Switch Unit This cable is not daisy chained between converters but serves as a direct link for each converter in the confi...

Страница 78: ...indicator 10 FAULT_INT2 Input RCU101 Manual Mode indicator A 14 FAULT_INT3 Input RCU101 Manual Mode indicator B 3 FAULT_INT3 N A Spare 7 ID_INT0 Input 11 ID_INT1 Input 15 ID_INT2 Input 4 ID_INT3 Input...

Страница 79: ...es a direct path for the RF Input through the switch module for non faulted conditions 5 13 2 J11 J11 is an SMA F Type Connector It is the RF Input of the SFC Upconverter in the chain switching config...

Страница 80: ...6 ID_OUT_SW0 Out Converter Position ID Bit 0 7 ID_OUT_SW2 Out Converter Position ID Bit 2 8 FAULT_SW1 In Switch Fault Indicator Prime 1 9 FAULT_SW3 In Switch Fault Indicator Prime 3 10 FAULT_SW5 In S...

Страница 81: ...6 ID_IN_SW0 In Converter Position ID Bit 0 7 ID_IN_SW2 In Converter Position ID Bit 2 8 FAULT_SW1 Out Switch Fault Indicator Prime 1 9 FAULT_SW3 Out Switch Fault Indicator Prime 3 10 FAULT_SW5 Out Sw...

Страница 82: ...Rear Panel Interfaces SFC6400A SFC1450A Synthesized Frequency Upconverter 5 10 TM106 Rev 1 1...

Страница 83: ...rter to change over time As with any converter these changes will affect the frequency accuracy and frequency conversion amplitude accuracy over time 6 1 Failure Analysis Faults in the converter are l...

Страница 84: ...Maintenance and Troubleshooting SFC6400A SFC1450A Synthesized Frequency Upconverter 6 2 TM106 Rev 1 1...

Страница 85: ...nal Impedance 75O Return Loss 23 dB P1 dBm Input 10 dBm Input Attenuator 30 dB 15 dBm Input Attenuator 0 dB Pin Nominal 5 dBm Input Attenuator 30 dB 25 dBm Input Attenuator 0 dB Connector BNC Type F N...

Страница 86: ...Technical Specifications SFC6400A SFC1450A Synthesized Frequency Upconverter 7 2 TM106 Rev 1 1 Parabolic 0 005 nsec MHz2 Ripple 1 nsec p p Carrier Mute 80 dBm minimum...

Страница 87: ...232 ASCII and RLLP RS 232 RS 485 Serial Interfaces and SNMP Ethernet Rear Panel Connections RF output N type IF input 75 Ohm BNC Operator Serial Port D sub 9 pin 10 MHz REF in 50 Ohm BNC 10 MHz REF O...

Страница 88: ...me Relay Status Compensation Control All Available Prime Converter Types 7 6 3 LED Indicators Standby LO Fault Signal Fault External Reference Online Backup Software Fault Manual Backup Only Power Fau...

Страница 89: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Technical Specifications TM106 Rev 1 1 7 5 Note These specifications are subject to change...

Страница 90: ...Technical Specifications SFC6400A SFC1450A Synthesized Frequency Upconverter 7 6 TM106 Rev 1 1...

Страница 91: ...line and keeps it there MANBACK forces the backup to replace the specified converter RAMGAIN sets the gain for another alternate channel RAMFREQ sets the frequency for another alternate channel ERASE...

Страница 92: ...ter input attenuation STORE Save current channel s frequency gain RAMGAINccsgg g Set stored gain for the specified channel RAMFREQccffff t Set stored frequency for the specified channel cr lf cr lf En...

Страница 93: ...mission A backup converter in a 1 for 1 configuration will return the following cr lf HELP Show all commands DATA Show data associated with commands STATUS Show status RFOFF Mutes the output RFON Unmu...

Страница 94: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 4 TM106 Rev 1 1 MANBACKn Force manual backup of converter n AUTO Place the switch in auto mode cr lf End of transmission...

Страница 95: ...Offline Warming up Offline Setup Online Channel cc cc current channel number 01 to 30 Frequency ffff fff ffff fff frequency in MHz Gain sgg g s and gg g gain in dB RSS aa dBm aa received signal streng...

Страница 96: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 6 TM106 Rev 1 1...

Страница 97: ...number Status Faulted Warming up Faulted Available Channel cc cc current channel number 01 to 30 Frequency ffff fff ffff fff frequency in MHz Gain sgg g s and gg g gain in dB Input Atten aa dB aa inp...

Страница 98: ...Priority n Prime 8 is not selected Online with a Priority n Online and Faulted with a Priority n Offline and Faulted with a Priority n Offline and Available with a Priority n Backup is Faulted Warmin...

Страница 99: ...106 Rev 1 1 A 9 cr lf cc channel 01 to 30 gg g gain 20 0 to 30 0 depending on Input Attenuation ffff frequency MHz ffff 0 to ffff 0 ffff 0 frequency in MHz low end to high end t Kilohertz step 0 to 7...

Страница 100: ...urn the following string of information cr lf There are no data specific commands for the backup converter in the one for one switch configuration cr lf cr lf End of transmission A 4 Show Received Sig...

Страница 101: ...imits Frequencies outside this range or frequencies that are of an invalid form will be responded to by the illegal frequency prompt If the synthesizer is unable to tune to the desired band and freque...

Страница 102: ...cr lf Channel cc cc current channel number 01 to 30 Frequency ffff fff ffff fff frequency in MHz Gain sgg g s and gg g gain in dB Input Atten aa dB aa input attenuation RF Off On Stored Faults None S...

Страница 103: ...lt Signal Fault Reference Internal External cr lf cr lf End of transmission A 9 Set Priority B1 8 This command is used to set the priorities of converters 1 8 respectively The command is as follows 01...

Страница 104: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 14 TM106 Rev 1 1 cr lf End of transmission...

Страница 105: ...transmission A 11 RF On Off Command Upconverter Only All These commands control the converter s output The commands are as follows 01 RFON cr 01 RFOFF cr Note If the converter is faulted any attempt...

Страница 106: ...Appendix A SFC6400A SFC1450A Synthesized Frequency Upconverter A 16 TM106 Rev 1 1...

Страница 107: ...is accidentally left in the Manual Mode from the Remote Port send a manual command to the converter that is Manually Deselected i e the one that is NOT selected Then send an Auto Command to the same c...

Страница 108: ...rters cr lf End of transmission cr lf Unable to perform manual backup Selected converter has a priority 0 cr lf End of transmission cr lf Unable to perform manual backup Selected converter was not suc...

Страница 109: ...sponse Prime did not respond Prime s incompatible with the Backup Prime s RF is turned off cr lf End of transmission cr lf Prime converter was successfully learned cr lf End of transmission A backup c...

Страница 110: ...FAILED because it s RF is turned off was successfully learned was not selected Converter 5 FAILED because of an invalid response FAILED because it did not respond FAILED because it s incompatible wit...

Страница 111: ...table DAC value for the given Frequency Index ff and the given Attenuation Index aa The command is as follows 01 RDATTENff aa cr Note Parameters are not actual values for frequency and attenuation bu...

Страница 112: ...e following string cr lf Gain Offset Value gg gg is the gain offset value cr lf cr lf End of transmission A 34 Dump Channel Table All This command returns the contents of the Channel Table The command...

Страница 113: ...g ffff f sgg g ffff f sgg g ffff f sgg g ffff f sgg g ffff f sgg g ffff f sgg g ffff f sgg g ffff f sgg g cr lf cr lf End of transmission where ffff f f frequency for channel entry sgg g s or gg g Ga...

Страница 114: ...Command is not valid for the backup converter cr lf End of transmission Not in backup 1 8 cr lf Command is not valid for the backup converter in a 1 for 8 configuration cr lf End of transmission Only...

Страница 115: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix A TM106 Rev 1 1 A 25 Bad channel cr lf ILLEGAL CHANNEL sb 01 to 30 cr lf cr lf End of transmission...

Страница 116: ...d input attenuation cr lf ILLEGAL INPUT ATTENUATION sb 00 to 30 cr lf cr lf End of transmission Converter is faulted cr lf Unable to turn RF on Check converter status cr lf End of transmission Remote...

Страница 117: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix A TM106 Rev 1 1 A 27...

Страница 118: ...s not aware of the newly added features to the product it should disregard the parameters at the end of the Non Volatile Section and index to the start of the Volatile Section Before creating any soft...

Страница 119: ...nd set converter configuration 3017h Command set converter alarm masks 3018h Command set backup mode 3030h Command force a manual backup 3031h Command learn converter configuration 3032h Command learn...

Страница 120: ...35 means release 3 5 Opcode 3005h Query firmware part number and release date Query response 8 8 Part Number String Release Date String FW4835xx xx represents the release version example B ASCII repre...

Страница 121: ...Appendix B SFC6400A SFC1450A Synthesized Frequency Upconverter B 4 TM106 Rev 1 1 1 Second 0 59...

Страница 122: ...oltage IF Input Power Voltage RF Detector Voltage 0 Standby 1 Online 2 Faulted 3 Setup 0 Not Present 1 Present 0 Down 1 Up 0 C Band 1 Ku Band 0 70 MHz 1 140 MHz 0 Internal 1 External Bit 0 LO Fault Bi...

Страница 123: ...uery response 1 1 1 1 1 Major Alarm Status Minor Alarm Status Latched Major Alarm Status Latched Minor Alarm Status Backed Up Prime Bit 0 Polling Fault Bit 1 Relay Fault Bits 2 7 Spares Bit 0 Learned...

Страница 124: ...decimal point Binary value one implied decimal point Binary value one implied decimal point Binary value one implied decimal point Binary value one implied decimal point Binary value one implied deci...

Страница 125: ...Opcode 2C06h Command set time and date 1 1 1 1 1 1 Year Month Day Hour Minute Second 0 99 0 11 0 30 0 23 0 59 0 59 Opcode 2C03h Command clear latched alarms No Command Data Opcode 3010h Command set f...

Страница 126: ...ation 1 Converter Config 0 Single 1 1F1 Primary 2 1F1 Backup 3 1F8 Primary 4 1F8 Backup Opcode 3018h Command set converter alarm masks 1 1 Major Alarm Mask Minor Alarm Bit 0 LO Fault Bit 1 Signal Faul...

Страница 127: ...06 Rev 1 1 1 Prime To Test 1 8 converter must be present Opcode 3035h Command backup test all converter configurations No data field for this opcode Opcode 3036h Command set compensation control 1 Com...

Страница 128: ...ation Prime 4 Compensation Prime 5 Compensation Prime 6 Compensation Prime 7 Compensation Prime 8 Compensation Note Command is only valid in Chain Switching Mode Binary value one implied decimal point...

Страница 129: ...part of the backup pool 0 8 0 means not part of the backup pool 0 8 0 means not part of the backup pool 0 8 0 means not part of the backup pool 0 8 0 means not part of the backup pool 0 8 0 means not...

Страница 130: ...number 2591 is a unique identifier assigned to Radyne by the Internet Assigned Numbers Authority IANA This number is used to uniquely define vendor specific information such as private MIBs radyne 12...

Страница 131: ...Prime2 status Bit2 Prime3 status Bit3 Prime4 status Bit4 Prime5 status Bit5 Prime6 status Bit6 Prime7 status Bit7 Prime8 status SYNTAX INTEGER 0 255 PrimeControlType TEXTUAL CONVENTION STATUS current...

Страница 132: ...0GHz Any other parameters could be different as well The advantage is that a completely different setup can be arrived at by merely changing the Channel number radConverterNVStatus 3 radConverterCarr...

Страница 133: ...dConverterStatus 2 radConverterSwitchPresentStatus OBJECT TYPE SYNTAX INTEGER not_present 1 present 2 MAX ACCESS read only STATUS current DESCRIPTION Shows switch status radConverterStatus 3 radConver...

Страница 134: ...ESCRIPTION Shows converter reference type radConverterStatus 8 radConverterMajorAlarmStatus OBJECT TYPE SYNTAX AlarmByteType MAX ACCESS read only STATUS current DESCRIPTION A bit field On startup the...

Страница 135: ...1 255 MAX ACCESS read only STATUS current DESCRIPTION radConverterStatus 13 radConverterICCType OBJECT TYPE SYNTAX INTEGER 0 255 MAX ACCESS read only STATUS current DESCRIPTION A bit field that shows...

Страница 136: ...NVStatus 2 radConverterSwitchBackupTest OBJECT TYPE SYNTAX PrimeControlType MAX ACCESS read write STATUS current DESCRIPTION Checks if Prime can be backed up radConverterSwitchNVStatus 3 radConverterS...

Страница 137: ...50 10000 MAX ACCESS read write STATUS current DESCRIPTION Sets the delay between the time a Fault occurs in a Prime unit and the time it is acknowledged by the Backup This only used in automatic backu...

Страница 138: ...Status 1 radConverterSwitchMinorAlarmStatus OBJECT TYPE SYNTAX AlarmByteType MAX ACCESS read only STATUS current DESCRIPTION A bit field On startup the agent initializes this to the value 00000000 B B...

Страница 139: ...Prime 8 0 No Fault 1 Fault radConverterSwitchStatus 5 radConverterSwitchRelayStatus OBJECT TYPE SYNTAX PrimeStatusType MAX ACCESS read only STATUS current DESCRIPTION Prime converter relay status Bit...

Страница 140: ...Prime 3 Bit 3 Prime 4 Bit 4 Prime 5 Bit 5 Prime 6 Bit 6 Prime 7 Bit 7 Prime 8 0 Fail 1 Pass radConverterSwitchStatus 9 radConverterSwitchPowerSenseStatus OBJECT TYPE SYNTAX PrimeStatusType MAX ACCESS...

Страница 141: ...RIPTION radConverterCommonNVStatus 1 radConverterCommonTerminalBaudRate OBJECT TYPE SYNTAX INTEGER baud_2400 1 baud_9600 2 baud_19200 3 MAX ACCESS read write STATUS current DESCRIPTION Selects termina...

Страница 142: ...e STATUS current DESCRIPTION Selects remote port Baud Rate radConverterCommonNVStatus 7 radConverterCommonRemoteLineControl OBJECT TYPE SYNTAX INTEGER rs232 1 rs485 2 MAX ACCESS read write STATUS curr...

Страница 143: ...DESCRIPTION A bit field On startup the agent initializes this to the value 00000000 B Bit 0 CPLD test fault Bit 1 FPGA test fault Bit 2 Eeprom test fault Bit 3 7 Spares 0 Pass 1 Fail radConverterCommo...

Страница 144: ...onverterCommonUserMaxFrequency OBJECT TYPE SYNTAX INTEGER 3620000 14750000 MAX ACCESS read only STATUS current DESCRIPTION User maximum frequency radConverterCommonStatus 6 radConverterCommonSynthesiz...

Страница 145: ...g systems radConverterMIBTrapPrefix OBJECT IDENTIFIER radConverterMIBTraps 0 radConverterColdStartTrap NOTIFICATION TYPE STATUS current DESCRIPTION Unexpected restart radConverterMIBTrapPrefix 1 radCo...

Страница 146: ...group radConverterGroups 2 radConverterSwitchNVStatusGroup OBJECT GROUP OBJECTS radConverterSwitchBackupMode radConverterSwitchLearn radConverterSwitchBackupTest radConverterSwitchForceBackup radConve...

Страница 147: ...verterCommonStatusGroup OBJECT GROUP OBJECTS radConverterCommonMajorAlarmStatus radConverterCommonMinorAlarmStatus radConverterCommonLatchedMajorAlarmStatus radConverterCommonLatchedMinorAlarmStatus r...

Страница 148: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Appendix C TM106 Rev 1 1 C 19 END...

Страница 149: ...Appendix C SFC6400A SFC1450A Synthesized Frequency Upconverter C 20 TM106 Rev 1 1...

Страница 150: ...Application Specific Integrated Circuit ATE Automatic Test Equipment B BER Bit Error Rate BERT Bit Error Rate Test Bit BIT Binary Digit or Built In Test BITE Built In Test Equipment bps Bits Per Secon...

Страница 151: ...t D I Drop and Insert E Eb N0 Ratio of Energy per bit to Noise Power Density in a 1 Hz Bandwidth EEPROM Electrically Erasable Programmable Read Only Memory EIA Electronic Industries Association EMI El...

Страница 152: ...tion Standards IF Intermediate Frequency INTELSAT International Telecommunication Satellite Organization ISO International Standards Organization J J Joule K Kbps Kilobits per Second Kbps Kilobytes pe...

Страница 153: ...Glossary SFC6400A SFC1450A Synthesized Frequency Upconverter G 4 TM106 Rev 1 1 M C Monitor and Control...

Страница 154: ...e Locked Loop ppb Parts per Billion ppm Parts per Million P N Part Number Q QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying R RAM Random Access Memory RF Radio Frequency ROM Rea...

Страница 155: ...Codes TRE Trellis Tx Transmit Transmitter TxD Transmit Data U UART Universal Asynchronous Receiver Transmitter UUT Unit Under Test V V Volts VAC Volts Alternating Current VCO Voltage Controlled Oscill...

Страница 156: ...SFC6400A SFC1450A Synthesized Frequency Upconverter Glossary TM106 Rev 1 1 G 7...

Отзывы: