1. INTENDED USE 

 

WLC  precision  scale  enables  fast  and  accurate  mass  measurements  under 
laboratory  and  industrial  conditions.  The  device  is  equipped  with  an  internal 
battery  which  allows  its  operation  in  places  where  there  is  no  access  to  the 
mains.  The  WLC  features  a  stainless  steel  weighing  pan,  and  a  backlit  LCD 
guaranteeing clear weighing result presentation.  

 

The  WLC  series  enables  weighing  loads  below  scale  (so  called  under-pan 
weighing).  This  is  an  alternative  for  loads  of  non-standard  dimensions  and 
shapes, and for loads generating magnetic field. 

 

 

2. WARRANTY CONDITIONS 

 

A.  RADWAG  feels  obliged  to  repair  or  exchange  all  elements  that  appear  

to be faulty by production or by construction.  

B.  Defining defects of unclear origin and means of their elimination can only 

be realized with assistance of manufacturer and user representatives. 

C.  RADWAG  does  not  bear  any  responsibility  for  damage  or  losses 

resulting  from  unauthorized  or  inadequate  performing  of  production  
or service processes. 

D.  The warranty does not cover: 

  mechanical  damage  caused  by  product  exploitation  other  than 

intended, damage of thermal and chemical origin, damage caused by 
lightning, overvoltage in the power network or other random event, 

  inappropriate cleaning habits. 

E.  Loss of warranty takes place if: 

  a repair is carried out outside RADWAG authorized service point, 

  service  claims  intrusion  into  mechanical  or  electronic  construction  

by unauthorized people, 

  the device does not bear company security stickers. 

F.  Warranty  conditions  outline  the  warranty  period  for  rechargeable 

batteries attached to the device for 12 months. 

G.  For detailed warranty conditions read the warranty certificate. 
H.  Contact with the central authorized service: +48 (48) 386 63 30. 

 

 

3. MAINTENANCE ACTIVITIES 

 

In order to ensure safety in the course of cleaning, it is necessary to disconnect 
the device from the mains. With this condition met, uninstall the weighing pan 
and other detachable components. 

 

 

Cleaning  the  weighing  pan  while  still  installed  may  cause 
damage of the measuring system. 

Содержание WLC

Страница 1: ......

Страница 2: ...2 APRIL 2021...

Страница 3: ...dusty environments In case of damage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery disch...

Страница 4: ...7 5 RECYCLING 8 6 MECHANICAL DESIGN 8 6 1 Dimensions 8 6 2 Connectors Arrangement 9 6 3 Pins Overview 10 6 4 Operation panel 10 7 INSTALLATION 11 7 1 Unpacking and Installation 11 7 2 Levelling 11 7 3...

Страница 5: ...om unauthorized or inadequate performing of production or service processes D The warranty does not cover mechanical damage caused by product exploitation other than intended damage of thermal and che...

Страница 6: ...lic solvent sodium carbonate to remove BASE use protogenic solvent mineral acid of various concentration In case of heavy contamination use brush and detergent nevertheless avoid detergents containing...

Страница 7: ...brasive substances Avoid using hard brush this may cause scratches It is recommended to use microfibre cloth While polishing the surface use circular movements Use clean dry cloth to make the surface...

Страница 8: ...they are not to be treated as a regular household waste Scales to be decommissioned must be decommissioned in accordance with valid legal regulations 6 MECHANICAL DESIGN 6 1 Dimensions Dimensions of W...

Страница 9: ...9 Dimensions of WLC C2 K scale Dimensions of WLC C2 R scale 6 2 Connectors Arrangement 1 power supply socket 2 RS232 1 connector 3 weighing platform cable inlet 4 RS232 2 connector option...

Страница 10: ...D Pin4 5VDC Pin5 GND RS232 2 connector DB9 M male 6 4 Operation panel Keys Press to switch the weighing device on off hold the key for about 1 second Function key press to change the working mode Pres...

Страница 11: ...g and Installation Unpack the device and place it on a flat and even surface Keep it far away from any sources of heat Remove transport lock WLC F1 WLC C2 Scales Install the weighing pan follow the be...

Страница 12: ...ext displayed reading unit is conditioned by scale type In case the weighing result is not zero after indication stabilisation press key 7 4 Warm Up Time For correct scale operation the workroom tempe...

Страница 13: ...nation Depending on the battery state a respective status is displayed on the screen for 2s 80 Battery power supply Battery power given in CHArGE Battery charge in progress The device is connected to...

Страница 14: ...ome screen To return to the home screen press key repeatedly 9 WEIGHING Load the weighing pan Read the result when stability marker is displayed To assure long term operation and correct mass measurem...

Страница 15: ...g in particular side shocks 10 DIAGRAMS OF CONNECTION CABLES scale computer cable scale printer cable EPSON 11 TECHNICAL SPECIFICATIONS For technical specifications of respective scales go to RADWAG w...

Страница 16: ...transmission Enter P5 ducE 5 1 PC submenu and set correct 5 1 3 Int parameter value No printout on a scale connected printer Incorrect printer port set in 5 2 1 Prt parameter Enter P5 ducE 5 2 Prtr s...

Страница 17: ...art mass error indication out of range 10 of start mass H i Display range of total mass on scale display exceeded in Totalizing mode u L o Too low battery charge The scale is about to shut down E r r...

Страница 18: ...18...

Отзывы: