background image

 

46 

Format:   

UH_XXXXX CR LF

, where: 

_ - 

space

,

 

XXXXX

 - mass format 

Response options: 

UH_OK CR LF 

  - command carried out 

ES CR LF 

  - command not recognised (mass format incorrect) 

 

Give value of min checkweighing threshold

 

Format:   

ODH CR LF

 

Response: 

DH_MASA CR LF 

- command carried out 

Response format: 

4-12 

13 

14 

15 

16 

17 

18 

19 

space 

mass 

space 

unit 

space 

CR 

LF 

 

Mass

 

  - 9 characters, right justification 

Unit

 

  - 3 characters, left justification 

Give value of max checkweighing threshold

 

Format:   

OUH CR LF

 

Response: 

UH_MASA CR LF 

- command carried out 

Response format: 

4-12 

13 

14 

15 

16 

17 

18 

19 

space 

mass 

space 

unit 

space 

CR 

LF 

 

Mass

 

  - 9 characters, right justification 

Unit

 

  - 3 characters, left justification 

Give scale serial number

 

 

Format: 

NB CR LF

 

 

Response options: 

 

Содержание HRP 1100

Страница 1: ...HRP Weighing Platforms SERIES High Resolution Platforms IMMU 31 07 07 18 EN USER MANUAL www radwag com...

Страница 2: ...2 JULY 2018...

Страница 3: ...2 3 HRP 16 32 Platform 16 2 4 HRP 62 120 Platform 17 2 5 HRP 150 300 Platform 21 2 6 HRP 300 1 600 1100 Platform 24 2 7 HRP 2000 Platform 29 3 ADJUSTMENT 34 3 1 Operator Start Mass 35 4 COMMUNICATION...

Страница 4: ...4 1 GENERAL INFORMATION 1 1 Dimensions HRP 16 32 HRP 62 120...

Страница 5: ...5 HRP 150 300 HRP 300 1 600 1100...

Страница 6: ...6 HRP 2000 1 2 Connectors Arrangement HRP 16 32...

Страница 7: ...7 HRP 62 120 HRP 150 300 300 1 600 1100 HRP 2000...

Страница 8: ...ctor No connector HY10 PUE7 1 PC power supply Connectors arrangement for PL xx HRP with Ethernet and IN OUT ETHERNET IN OUT RS232 RS485 optional connector power supply Connectors arrangement for PL xx...

Страница 9: ...me and lets to avoid performing the process manually making it comfortable and easy Features Brand new design of the electromagnetic mechanism housed in a stainless steel dust proof and waterproof cas...

Страница 10: ...ghing pan with loads of gross weight which does not exceed maximum capacity D In case of eccentric loading make sure that a the weight of loads placed close to one of the pan edges does not exceed of...

Страница 11: ...it until the platform reaches thermal stabilisation Platforms stored in much lower temperatures than the workroom temperature before being plugged to the mains e g during winter period must be subject...

Страница 12: ...by lightning overvoltage in the power network or other random event damage caused by product exploitation other than intended mechanical damage if service claims removing or destroying protective sti...

Страница 13: ...ing instrument 1 11 Maintenance Caution Be careful so as not to damage the mechanism For maintenance use mild cleanser preventing corrosion Avoid directing strong stream of water directly onto weighin...

Страница 14: ...ge amount of water mixed with cleanser is a must Cleaning Aluminium Components While cleaning aluminium components use products acid by nature e g spirit vinegar lemon Do not use cleansers containing...

Страница 15: ...and install them Be particularly careful while unpacking the device and installing its components so as not to cause any damages to the platform mechanism Do it in accordance with the description belo...

Страница 16: ...he weighing module For detailed description of connectors refer to section 1 2 of this user manual 4 Place the platform at the place of use on a flat and even surface Keep it far away from any sources...

Страница 17: ...rm 1 Take the platform out of the packaging make sure that you touch OUTER FRAME only 2 Connect the indicator or computer to the weighing module For detailed description of connectors refer to section...

Страница 18: ...18 3 Install weighing pan receivers fit them into lever seats...

Страница 19: ...19 4 Disassemble transport lock by undoing screws and removing fixing washers 5 Place the device on a flat and even surface Keep it far away from any sources of heat do not assemble the weighing pan...

Страница 20: ...evel the platform using feet no 1 2 and 4 until the air bubble takes central position YES NO 8 Unscrew foot no 3 so that it rests on the ground Do not exert stress on platform frame Do not change the...

Страница 21: ...21 10 Connect the scale to the power supply 2 5 HRP 150 300 Platform 1 Take the platform out of the packaging make sure that you touch OUTER FRAME only...

Страница 22: ...to the weighing module For detailed description of connectors refer to section 1 2 of this user manual 3 Install weighing pan receivers fit them into lever seats 4 Disassemble transport lock by undoi...

Страница 23: ...it far away from any sources of heat do not assemble the weighing pan 6 Screw foot no 3 so that feet no 1 2 4 form a plain surface on which platform frame is based 7 Level the platform using feet no...

Страница 24: ...atform frame Do not change the level of the platform the air bubble has to remain in central position 9 Install the weighing pan 5 10 Connect the scale to the power supply 2 6 HRP 300 1 600 1100 Platf...

Страница 25: ...2 Connect the indicator or computer to the weighing module For detailed description of connectors refer to section 1 2 of this user manual 3 Install weighing pan receivers 4 fit them into lever seats...

Страница 26: ...26 4 Disassemble transport lock by undoing screws and removing fixing washers 6...

Страница 27: ...2 4 form a plain surface on which platform frame is based 7 Level the platform using feet no 1 2 and 4 until the air bubble takes central position YES NO 8 Unscrew foot no 3 so that it rests on the gr...

Страница 28: ...28 10 Connect the scale to the power supply...

Страница 29: ...ging using hoist Procedure Unscrew 4 screws presented in the figure below Screw 4 screws with eyelets Using cords and hoist take the platform out of the packaging and place in the place of use on a fl...

Страница 30: ...e place of use unscrew the screws with eyelets 2 Disassemble the top of the weighing platform 3 3 Connect the indicator or computer to the weighing module For detailed description of connectors refer...

Страница 31: ...s 5 5 Set the bumpers Loosen the nuts in all four corners Unscrew the screws and set 1 mm gap Tighten the nuts 6 Place the device on a flat and even surface Keep it far away from any sources of heat d...

Страница 32: ...evel the platform using feet no 1 2 and 4 until the air bubble takes central position YES NO 9 Unscrew foot no 3 so that it rests on the ground Do not exert stress on platform frame Do not change the...

Страница 33: ...33 11 Connect the scale to the power supply...

Страница 34: ...ried out Follow the displayed messages HRP platforms are equipped with an internal weight the adjustment can be carried out using either this weight or an external one There are three types of adjustm...

Страница 35: ...point of HRP platforms Option can be set using MWMH Manager program for platforms and modules operation weighing indicator connected to the module CAUTION Determination of start mass carried out by an...

Страница 36: ...nication has been described in a separate user manual In addition the platform can be equipped with digital inputs and outputs which enable taring zeroing dosing start and stop threshold signalling an...

Страница 37: ...les communication with peripheral devices using RS232 RS485 and Ethernet MWMH Manager software has been described in a separate user manual 4 4 Cooperation with Weighing Indicators HRP platforms are c...

Страница 38: ...vice via RS 232C RS 484 or Ethernet interface The protocol consists of commands sent from a peripheral device to the platform and responses from the weighing device Responses are sent from the platfor...

Страница 39: ...g threshold UH Set max checkweighing threshold ODH Give value of min checkweighing threshold OUH Give value of max checkweighing threshold NB Give balance serial number UI Give accessible units US Set...

Страница 40: ...LF time limit exceeded while waiting for stable measurement result time limit is a characteristic module parameter XX name of a sent command _ space 4 7 Commands Overview Zeroing Format Z CR LF Respo...

Страница 41: ...this moment Give tare value Format OT CR LF Response OT_TARE CR LF command carried out Response format 1 2 3 4 12 13 14 15 16 17 18 19 O T space tare space unit space CR LF Tare 9 characters right jus...

Страница 42: ...1 S space stability marker space character mass space unit CR LF Example S CR LF command sent from a computer S _ A CR LF command understood and in progress S _ _ _ _ _ _ _ _ _ _ 8 5 _ g _ _ CR LF com...

Страница 43: ...LF time limit exceeded while waiting for stable measurement result SU_I CR LF command understood but not accessible at this moment MASS FRAME command carried out immediate response mass value in basi...

Страница 44: ...carried out immediate response mass value in basic measuring unit where _ space Switch on continuous transmission in basic measuring unit Format C1 CR LF Response options C1_I CR LF command understood...

Страница 45: ...nt measuring unit Response format 1 2 3 4 5 6 7 15 16 17 18 19 20 21 S U I stability marker space character mass space unit CR LF Switch off continuous transmission in current measuring unit Format CU...

Страница 46: ...ormat 1 2 3 4 12 13 14 15 16 17 18 19 D H space mass space unit space CR LF Mass 9 characters right justification Unit 3 characters left justification Give value of max checkweighing threshold Format...

Страница 47: ...ble units UI_I CR LF command understood but not accessible at this moment x unit symbol separated by means of commas Example UI CR LF give available units UI_ kg N lb u1 u2 _OK CR LF response availabl...

Страница 48: ...g Give module type Format BN CR LF Response options BN_A_ x CR LF command understood response weighing device type BN_I CR LF command understood but not accessible at this moment x weighing device typ...

Страница 49: ...F give program version RV_A_ 1 0 0 CR LF response program version 1 0 0 Set autozero Format A_n CR LF Response options A_OK CR LF command carried out A_E CR LF error in course of command execution no...

Страница 50: ...igned to a particular filter name and it is identical for all balance types The command changes settings for a current working mode if for a particular balance type filter settings are assigned to the...

Страница 51: ...XXXX outputs status setting active 1 or not active 0 starting from output No 4 to output No 1 Response options SOUT_OK CR LF command carried out ES CR LF command not recognised incorrect outputs mask...

Страница 52: ...Value beyond zero range Err3 Value beyond tare range Err8 Zeroing taring operation time exceeded NULL Zero value from converter FULL Measuring range Max capacity exceeded LH Start mass error 4 9 Commu...

Страница 53: ...53 RS232 HRP HY10 PUE 5 cable power supply Ethernet HRP HY10 PUE 5 cables...

Страница 54: ...54 Ethernet HRP Ethernet Switch Pue 7 1 cable HRP IN OUT cable...

Страница 55: ...latform use SYS 1544 2415 T3 HRP power supply that is included in the set with the module In case of communication via PT0348 or PT0375 cables the power supply has to be plugged to the connector that...

Страница 56: ...ng Keep all package elements should your device be transported in the future Remember that only original packaging can be used for shipping purposes Prior packing uncouple any cables remove any separa...

Страница 57: ...57...

Страница 58: ...58...

Отзывы: