If you would like control or error response messages to be sent, ICMP (ping) should be
enabled.
•
If you are performing configuration procedures or would like to receive traps, SNMP should
be enabled.
Note
You can view trap events in the Events tab of the web user interface.
Note
Using encryption is subject to local regulation. In some countries it is restricted or limited for
usage. For more information, consult your local reseller.
Procedure
Step 1
Access the MCU security settings by selecting Configuration > Setup.
Step 2
Locate the Security section.
Step 3
Select the access level from the Security Mode list (see
).
lists the protocol status when each security access level is applied.
Figure 5-15
Security Access Level Settings
Table 5-2
MCU Security Access Levels
Security Access
Level
SSH
FTP
SNMP
ICMP (ping)
Standard
Enabled
Enabled
Enabled
Enabled
High
Disabled
Disabled
Enabled
Enabled
Maximum
Disabled
Disabled
Disabled
Disabled
Step 4
Select Apply.
Verifying the MCU Installation
After you installed the device and performed its initial configuration, you need to verify that
it is installed and configured correctly.
RADVISION | Installation Guide for Scopia Elite 6000 Series MCU Version 8.0
Performing the MCU Initial Configuration | 44