FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RA
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0.
81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec
-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
Winter
Autumn
Summer
Spring
Daily radon concentration
Day
Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When Ra is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RA
C_device
P_device
M
ea
sured va
lue
12h
2
4
h
36h
Actual value
1h
RadonFTLab
0.
81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling Ra device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
Ra setting
GPS
Bluetooth
RadonEye +
Ra is the world's first IoT smart radon detector that is used in connec
-
tion with web database based on WiFi. Therefore, Ra is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of Ra is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
Ra has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
Ra offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time chec
k
ing
Web access
Mobile notification
Wi
Fi, Bluetooth
Radon
,
H
umidity
,
Temperature
O
O
O
0.1
~
255 pCi/l
(1
~
9,4
35
Bq/㎥)
Model
RadonEye (RD200)
Ra (RD200P2)
B
luetooth
Radon
X
X
X
0.1
~
100 pCi/l
(1
~
3
,7
00
Bq/㎥)
< ±10
%
at 10pCi/l (3
7
0
Bq/㎥)
< ±10
%
(min. error <±0.5pCi/l)
ma
x
1year(1hour interval)
0.
9
6 inch O
L
ED
< RadonEye VS Ra >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
Ra provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2