IMPORTANT INSTRUCTIONS TO INSTALLER 

 

Inspect the GPx01/XP/XR Series Fan for shipping damage within 15 days of receipt. Notify RadonAway of any damages 
immediately. Radonaway is not responsible for damages incurred during shipping. However, for your benefit, 
Radonaway does insure shipments. 
 
There are no user serviceable parts inside the fan. 

Do not attempt to open. 

Return unit to factory for service. 

 

Install the GPx01/XP/XR Series Fan in accordance with all EPA standard practices, and state and local building codes  

and state regulations.  

 

 

WARRANTY 

 

Subject to any applicable consumer protection legislation, RadonAway warrants that the GPx01/XP/XR Series Fan (the “Fan”) will  be free from 

defects in materials and workmanship for a period of  90 days from the date of purchase (the “Warranty Term”).  

 

RadonAway will replace any Fan which fails due to defects in materials or workmanship.  The Fan must be returned (at Owner’s cost) to the 

RadonAway factory. Any Fan returned to the factory will be discarded unless the Owner provides specific instructions along with the Fan when it is 

returned regardless of whether or not the Fan is actually replaced under this warranty. Proof of purchase must be supplied upon request for 

service under this Warranty. 

 

This Warranty is contingent on installation of the Fan in accordance with the instructions provided.  This Warranty does not apply where any 

repairs or alterations have been made or attempted by others, or if the unit has been abused or misused.  Warranty does not  cover damage in 

shipment unless the damage is due to the negligence of RadonAway.  

 

5 YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION. 

 

RadonAway will extend the Warranty Term of the fan to 5 years from date of manufacture if the Fan is installed in a professionally designed and 

professionally installed radon system or installed as a replacement fan in a professionally designed and professionally installed radon system. 

Proof  of purchase and/or proof of professional installation may be required for service under this warranty. Outside the Continental United States 

and Canada the extended Warranty Term is limited to one (1) year from the date of manufacture. 

 

RadonAway is not responsible for installation, removal or delivery costs associated with this Warranty.   

  

EXCEPT AS STATED ABOVE, THE GPx01/XP/XR SERIES FANS ARE PROVIDED WITHOUT WARRANTY 
OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

 

IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, 
OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN OR THE 

PERFORMANCE THEREOF.  RADONAWAY’S AGGREGATE LIABILITY HEREUNDER SHALL NOT IN 

ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT.  THE SOLE AND 

EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE 

PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH RADONAWAY’S WARRANTY AS 
PROVIDED ABOVE.

 

 

For service under this Warranty, contact RadonAway for a Return Material Authorization (RMA) number and shipping 

information.  No returns can be accepted without an RMA.  If factory return is required, the customer assumes all shipping 

cost to and from factory. 

 

RadonAway  

3 Saber Way  

Ward Hill, MA 01835 
TEL. (978) 521-3703 

FAX (978) 521-3964 

 

Record the following information for your records: 
 

Serial 

No.       

Purchase 

Date 

    

 

 

 

Содержание XP101

Страница 1: ...o open Return unit to the factory for service 6 All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed by a qualified and licensed electrician 7 WARNING Do not leave fan unit installed on system piping w...

Страница 2: ... considered in the overall system design In some cases the rushing sound of the outlet air may be disturbing In these instances the use of a RadonAway Exhaust Muffler is recommended 1 4 GROUND WATER In the event that a temporary high water table results in water at or above slab level water may be drawn into the riser pipes thus blocking air flow to the GP XP XR Series Fan The lack of cooling air ...

Страница 3: ... 90 CFM For more precision determine flow rate by using the chart in the addendum Under some circumstances in an outdoor installation a condensate bypass should be installed in the outlet ducting as shown This may be particularly true in cold climate installations which require long lengths of outlet ducting or where the outlet ducting is likely to produce large amounts of condensation because of ...

Страница 4: ...or electrical boxes are outdoor rated and properly sealed to prevent water penetration into the box A means such as a weep hole is recommended to drain the box 1 9 SPEED CONTROLS The GP XP XR Series Fans are rated for use with electronic speed controls however they are generally not recommended If used the speed control recommended is Pass Seymour Solid State Speed Control Cat No 94601 I 2 0 INSTA...

Страница 5: ...solation 2 4 ELECTRICAL CONNECTION Connect wiring with wire nuts provided observing proper connections See Section 1 8 2 5 VENT MUFFLER optional Install the muffler assembly in the selected location in the outlet ducting Solvent weld all connections The muffler is normally installed at the end of the vent pipe 2 6 OPERATION CHECKS _____ Verify all connections are tight and leak free _____ Insure t...

Страница 6: ...peration Reduce by 10 for High Temperature Operation Reduce by 4 per 1000 feet of altitude Power Consumption 120 VAC XP101 40 49 watts XP151 45 60 watts XP201 45 66 watts XR261 65 105 watts XP Series Inlet Outlet 4 5 OD 4 0 PVC Sched 40 size compatible XR Series Inlet Outlet 5 875 OD Mounting Mount on the duct pipe or with optional mounting bracket Recommended ducting 3 or 4 Schedule 20 40 PVC Pip...

Страница 7: ...ation Reduce by 10 for High Temperature Operation Reduce by 4 per 1000 feet of altitude Power Consumption 120 VAC GP501 70 140 watts GP401 60 110 watts GP301 55 90 watts GP201 40 60 watts Inlet Outlet 3 5 OD 3 0 PVC Sched 40 size compatible Mounting Fan may be mounted on the duct pipe or with integral flanges Weight 12 lbs Size 13H x 12 5 x 12 5 Recommended ducting 3 or 4 Schedule 20 40 PVC Pipe S...

Страница 8: ...donAway 5 YEAR EXTENDEDWARRANTY WITH PROFESSIONAL INSTALLATION RadonAway will extend the Warranty Term of the fan to 5 years from date of manufacture if the Fan is installed in a professionally designed and professionally installed radon system or installed as a replacement fan in a professionally designed and professionally installed radon system Proof of purchase and or proof of professional ins...

Отзывы: