IN006 Rev K 0417

2

3 Saber Way, Ward Hill, MA 01835   |   radonaway.com

GP500 Series Fan Installation & Operating Instructions

Please Read and Save These Instructions.

DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL 

SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.

1. WARNING! Do not use fan in hazardous environments where fan electrical system could provide ignition to 
    combustible or flammable materials.

2. WARNING! Do not use fan to pump explosive or corrosive gases. See Vapor Intrusion Application Note #AN001 
    for important information on VI applications. RadonAway.com/vapor-intrusion

3. WARNING! Check voltage at the fan to ensure it corresponds with nameplate.

4. WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of fuel 
    burning equipment. Check for possible backdraft conditions on all combustion devices after installation.

5. NOTICE! There are no user serviceable parts located inside the fan unit.
    Do NOT attempt to open. Return unit to the factory for service.

6. All wiring must be performed in accordance with the National Fire Protection Association’s (NFPA)”National 
    Electrical Code, Standard #70”-current edition for all commercial and industrial work, and state and local 
    building codes. All wiring must be performed by a qualified and licensed electrician.

7. WARNING! Do not leave fan unit installed on system piping without electrical power for more than 48 hours.  
    Fan failure could result from this non-operational storage.

8. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
    FOLLOWING:

 

a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

 manufacturer.

 

b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting 

 

means to prevent power from being switched on accidentally. When the service disconnecting means 

 

cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Содержание GP500

Страница 1: ...IN006 Rev K 0417 1 3 Saber Way Ward Hill MA 01835 radonaway com GP500 Installation Operating Instructions...

Страница 2: ...r installation 5 NOTICE There are no user serviceable parts located inside the fan unit Do NOT attempt to open Return unit to the factory for service 6 All wiring must be performed in accordance with...

Страница 3: ...led properly operates with little or no noticeable noise to the building occupants Ensure a solid mounting for the GP500 to avoid structure borne vibration or noise The velocity of the outgoing air mu...

Страница 4: ...tem malfunction A System Label P N 15022 with instructions for contacting the installing contractor for service and also identifying the necessity for regular radon tests to be conducted by the buildi...

Страница 5: ...electrical tape to seal out moisture A rubber splicing tape or self fusing silicone tape provide best moisture seal 2 2 OUTDOOR BAND JOIST OR SIDEWALL 1 Locate site for GP500 mounting Use the diagram...

Страница 6: ...ducting is secure and vibration free ____ Verify system vacuum pressure with Manometer or other pressure gauge Ensure vacuum pressure is within normal operating range and less than 3 8 WC based on sea...

Страница 7: ...nder this Warranty This Warranty is contingent on installation of the Fan in accordance with the instructions provided This Warranty does not apply where any repairs or alterations have been made or a...

Отзывы: